Cargando…

Prioritisation of patients on waiting lists for hip and knee arthroplasties and cataract surgery: Instruments validation

BACKGROUND: Prioritisation instruments were developed for patients on waiting list for hip and knee arthroplasties (AI) and cataract surgery (CI). The aim of the study was to assess their convergent and discriminant validity and inter-observer reliability. METHODS: Multicentre validation study which...

Descripción completa

Detalles Bibliográficos
Autores principales: Allepuz, Alejandro, Espallargues, Mireia, Moharra, Montse, Comas, Mercè, Pons, Joan MV
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2373288/
https://www.ncbi.nlm.nih.gov/pubmed/18397519
http://dx.doi.org/10.1186/1472-6963-8-76
_version_ 1782154363020509184
author Allepuz, Alejandro
Espallargues, Mireia
Moharra, Montse
Comas, Mercè
Pons, Joan MV
author_facet Allepuz, Alejandro
Espallargues, Mireia
Moharra, Montse
Comas, Mercè
Pons, Joan MV
author_sort Allepuz, Alejandro
collection PubMed
description BACKGROUND: Prioritisation instruments were developed for patients on waiting list for hip and knee arthroplasties (AI) and cataract surgery (CI). The aim of the study was to assess their convergent and discriminant validity and inter-observer reliability. METHODS: Multicentre validation study which included orthopaedic surgeons and ophthalmologists from 10 hospitals. Participating doctors were asked to include all eligible patients placed in the waiting list for the procedures under study during the medical visit. Doctors assessed patients' priority through a visual analogue scale (VAS) and administered the prioritisation instrument. Information on socio-demographic data and health-related quality of life (HRQOL) (HUI3, EQ-5D, WOMAC and VF-14) was obtained through a telephone interview with patients. The correlation coefficients between the prioritisation instrument score and VAS and HRQOL were calculated. For the reliability study a self-administered questionnaire, which included hypothetic patients' scenarios, was sent via postal mail to the doctors. The priority of these scenarios was assessed through the prioritisation instrument. The intraclass correlation coefficient (ICC) between doctors was calculated. RESULTS: Correlations with VAS were strong for the AI (0.64, CI95%: 0.59–0.68) and for the CI (0.65, CI95%: 0.62–0.69), and moderate between the WOMAC and the AI (0.39, CI95%: 0.33–0.45) and the VF-14 and the CI (0.38, IC95%: 0.33–0.43). The results of the discriminant analysis were in general as expected. Inter-observer reliability was 0.79 (CI95%: 0.64–0.94) for the AI, and 0.79 (CI95%: 0.63–0.95) for the CI. CONCLUSION: The results show acceptable validity and reliability of the prioritisation instruments in establishing priority for surgery.
format Text
id pubmed-2373288
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-23732882008-05-07 Prioritisation of patients on waiting lists for hip and knee arthroplasties and cataract surgery: Instruments validation Allepuz, Alejandro Espallargues, Mireia Moharra, Montse Comas, Mercè Pons, Joan MV BMC Health Serv Res Research Article BACKGROUND: Prioritisation instruments were developed for patients on waiting list for hip and knee arthroplasties (AI) and cataract surgery (CI). The aim of the study was to assess their convergent and discriminant validity and inter-observer reliability. METHODS: Multicentre validation study which included orthopaedic surgeons and ophthalmologists from 10 hospitals. Participating doctors were asked to include all eligible patients placed in the waiting list for the procedures under study during the medical visit. Doctors assessed patients' priority through a visual analogue scale (VAS) and administered the prioritisation instrument. Information on socio-demographic data and health-related quality of life (HRQOL) (HUI3, EQ-5D, WOMAC and VF-14) was obtained through a telephone interview with patients. The correlation coefficients between the prioritisation instrument score and VAS and HRQOL were calculated. For the reliability study a self-administered questionnaire, which included hypothetic patients' scenarios, was sent via postal mail to the doctors. The priority of these scenarios was assessed through the prioritisation instrument. The intraclass correlation coefficient (ICC) between doctors was calculated. RESULTS: Correlations with VAS were strong for the AI (0.64, CI95%: 0.59–0.68) and for the CI (0.65, CI95%: 0.62–0.69), and moderate between the WOMAC and the AI (0.39, CI95%: 0.33–0.45) and the VF-14 and the CI (0.38, IC95%: 0.33–0.43). The results of the discriminant analysis were in general as expected. Inter-observer reliability was 0.79 (CI95%: 0.64–0.94) for the AI, and 0.79 (CI95%: 0.63–0.95) for the CI. CONCLUSION: The results show acceptable validity and reliability of the prioritisation instruments in establishing priority for surgery. BioMed Central 2008-04-08 /pmc/articles/PMC2373288/ /pubmed/18397519 http://dx.doi.org/10.1186/1472-6963-8-76 Text en Copyright © 2008 Allepuz et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Allepuz, Alejandro
Espallargues, Mireia
Moharra, Montse
Comas, Mercè
Pons, Joan MV
Prioritisation of patients on waiting lists for hip and knee arthroplasties and cataract surgery: Instruments validation
title Prioritisation of patients on waiting lists for hip and knee arthroplasties and cataract surgery: Instruments validation
title_full Prioritisation of patients on waiting lists for hip and knee arthroplasties and cataract surgery: Instruments validation
title_fullStr Prioritisation of patients on waiting lists for hip and knee arthroplasties and cataract surgery: Instruments validation
title_full_unstemmed Prioritisation of patients on waiting lists for hip and knee arthroplasties and cataract surgery: Instruments validation
title_short Prioritisation of patients on waiting lists for hip and knee arthroplasties and cataract surgery: Instruments validation
title_sort prioritisation of patients on waiting lists for hip and knee arthroplasties and cataract surgery: instruments validation
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2373288/
https://www.ncbi.nlm.nih.gov/pubmed/18397519
http://dx.doi.org/10.1186/1472-6963-8-76
work_keys_str_mv AT allepuzalejandro prioritisationofpatientsonwaitinglistsforhipandkneearthroplastiesandcataractsurgeryinstrumentsvalidation
AT espallarguesmireia prioritisationofpatientsonwaitinglistsforhipandkneearthroplastiesandcataractsurgeryinstrumentsvalidation
AT moharramontse prioritisationofpatientsonwaitinglistsforhipandkneearthroplastiesandcataractsurgeryinstrumentsvalidation
AT comasmerce prioritisationofpatientsonwaitinglistsforhipandkneearthroplastiesandcataractsurgeryinstrumentsvalidation
AT ponsjoanmv prioritisationofpatientsonwaitinglistsforhipandkneearthroplastiesandcataractsurgeryinstrumentsvalidation
AT prioritisationofpatientsonwaitinglistsforhipandkneearthroplastiesandcataractsurgeryinstrumentsvalidation