Cargando…
Diabetic retinopathy is associated with pulse wave velocity, not with the augmentation index of pulse waveform
BACKGROUND: To investigate the clinical differences between pulse wave velocity and augmentation index in diabetic retinopathy. METHODS: The subjects were 201 patients with type 2 diabetes. These subjects were measured for both augmentation index (AI) and brachial-ankle pulse wave velocity (baPWV) b...
Autores principales: | , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2377239/ https://www.ncbi.nlm.nih.gov/pubmed/18439284 http://dx.doi.org/10.1186/1475-2840-7-11 |
_version_ | 1782154797624852480 |
---|---|
author | Ogawa, Osamu Hiraoka, Kiyoko Watanabe, Takahiro Kinoshita, Junichiro Kawasumi, Masahiko Yoshii, Hidenori Kawamori, Ryuzo |
author_facet | Ogawa, Osamu Hiraoka, Kiyoko Watanabe, Takahiro Kinoshita, Junichiro Kawasumi, Masahiko Yoshii, Hidenori Kawamori, Ryuzo |
author_sort | Ogawa, Osamu |
collection | PubMed |
description | BACKGROUND: To investigate the clinical differences between pulse wave velocity and augmentation index in diabetic retinopathy. METHODS: The subjects were 201 patients with type 2 diabetes. These subjects were measured for both augmentation index (AI) and brachial-ankle pulse wave velocity (baPWV) by a pulse wave analyzer. The relationships between AI, baPWV, and diabetic retinopathy were examined. RESULTS: BaPWV was significantly higher in patients with diabetic retinopathy than in individuals without the disease. (20.13 ± 3.66 vs.17.14 ± 3.60 m/s p < 0.001) AI was higher in patients with diabetic retinopathy, but not significantly. (19.5 ± 15.2 vs. 14.8 ± 20.5% p = 0.14) The association between baPWV and diabetic retinopathy remained statistically significant after adjustment. (Odds ratio: 1.21 Per m/s, 95% confidence interval: 1.07–1.37) On the other hand, the association between AI and diabetic retinopathy was not statistically significant. (Odds ratio: 1.01 Per %, 95% confidence interval: 0.98–1.03) CONCLUSION: BaPWV is associated with diabetic retinopathy, but AI is not. The clinical significance appears to be different between PWV and AI in patients with diabetes. |
format | Text |
id | pubmed-2377239 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2008 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-23772392008-05-13 Diabetic retinopathy is associated with pulse wave velocity, not with the augmentation index of pulse waveform Ogawa, Osamu Hiraoka, Kiyoko Watanabe, Takahiro Kinoshita, Junichiro Kawasumi, Masahiko Yoshii, Hidenori Kawamori, Ryuzo Cardiovasc Diabetol Original Investigation BACKGROUND: To investigate the clinical differences between pulse wave velocity and augmentation index in diabetic retinopathy. METHODS: The subjects were 201 patients with type 2 diabetes. These subjects were measured for both augmentation index (AI) and brachial-ankle pulse wave velocity (baPWV) by a pulse wave analyzer. The relationships between AI, baPWV, and diabetic retinopathy were examined. RESULTS: BaPWV was significantly higher in patients with diabetic retinopathy than in individuals without the disease. (20.13 ± 3.66 vs.17.14 ± 3.60 m/s p < 0.001) AI was higher in patients with diabetic retinopathy, but not significantly. (19.5 ± 15.2 vs. 14.8 ± 20.5% p = 0.14) The association between baPWV and diabetic retinopathy remained statistically significant after adjustment. (Odds ratio: 1.21 Per m/s, 95% confidence interval: 1.07–1.37) On the other hand, the association between AI and diabetic retinopathy was not statistically significant. (Odds ratio: 1.01 Per %, 95% confidence interval: 0.98–1.03) CONCLUSION: BaPWV is associated with diabetic retinopathy, but AI is not. The clinical significance appears to be different between PWV and AI in patients with diabetes. BioMed Central 2008-04-25 /pmc/articles/PMC2377239/ /pubmed/18439284 http://dx.doi.org/10.1186/1475-2840-7-11 Text en Copyright © 2008 Ogawa et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Investigation Ogawa, Osamu Hiraoka, Kiyoko Watanabe, Takahiro Kinoshita, Junichiro Kawasumi, Masahiko Yoshii, Hidenori Kawamori, Ryuzo Diabetic retinopathy is associated with pulse wave velocity, not with the augmentation index of pulse waveform |
title | Diabetic retinopathy is associated with pulse wave velocity, not with the augmentation index of pulse waveform |
title_full | Diabetic retinopathy is associated with pulse wave velocity, not with the augmentation index of pulse waveform |
title_fullStr | Diabetic retinopathy is associated with pulse wave velocity, not with the augmentation index of pulse waveform |
title_full_unstemmed | Diabetic retinopathy is associated with pulse wave velocity, not with the augmentation index of pulse waveform |
title_short | Diabetic retinopathy is associated with pulse wave velocity, not with the augmentation index of pulse waveform |
title_sort | diabetic retinopathy is associated with pulse wave velocity, not with the augmentation index of pulse waveform |
topic | Original Investigation |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2377239/ https://www.ncbi.nlm.nih.gov/pubmed/18439284 http://dx.doi.org/10.1186/1475-2840-7-11 |
work_keys_str_mv | AT ogawaosamu diabeticretinopathyisassociatedwithpulsewavevelocitynotwiththeaugmentationindexofpulsewaveform AT hiraokakiyoko diabeticretinopathyisassociatedwithpulsewavevelocitynotwiththeaugmentationindexofpulsewaveform AT watanabetakahiro diabeticretinopathyisassociatedwithpulsewavevelocitynotwiththeaugmentationindexofpulsewaveform AT kinoshitajunichiro diabeticretinopathyisassociatedwithpulsewavevelocitynotwiththeaugmentationindexofpulsewaveform AT kawasumimasahiko diabeticretinopathyisassociatedwithpulsewavevelocitynotwiththeaugmentationindexofpulsewaveform AT yoshiihidenori diabeticretinopathyisassociatedwithpulsewavevelocitynotwiththeaugmentationindexofpulsewaveform AT kawamoriryuzo diabeticretinopathyisassociatedwithpulsewavevelocitynotwiththeaugmentationindexofpulsewaveform |