Comparison of standard and double reading and computer-aided detection (CAD) of interval cancers at prior negative screening mammograms: blind review

The study evaluates the role of computer-aided detection (CAD) in improving the detection of interval cancers as compared to conventional single (CONV) or double reading (DOUBLE). With this purpose, a set of 89 negative cases was seeded with 31 mammograms reported as negative and developing interval...

Descripción completa

Detalles Bibliográficos
Autores principales: Ciatto, S, Del Turco, M Rosselli, Burke, P, Visioli, C, Paci, E, Zappa, M
Formato: Texto
Lenguaje:English
Publicado: Nature Publishing Group 2003
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2394421/
https://www.ncbi.nlm.nih.gov/pubmed/14583763
http://dx.doi.org/10.1038/sj.bjc.6601356
_version_ 1782155412004405248
author Ciatto, S
Del Turco, M Rosselli
Burke, P
Visioli, C
Paci, E
Zappa, M
author_facet Ciatto, S
Del Turco, M Rosselli
Burke, P
Visioli, C
Paci, E
Zappa, M
author_sort Ciatto, S
collection PubMed
description The study evaluates the role of computer-aided detection (CAD) in improving the detection of interval cancers as compared to conventional single (CONV) or double reading (DOUBLE). With this purpose, a set of 89 negative cases was seeded with 31 mammograms reported as negative and developing interval cancer in the following 2-year interval (false negative (FN)=11, minimal signs (MS)=20). A total of radiologists read the set with CONV and then with CAD. Overall, there were 589 cancer and 1691 noncancer readings with both CONV and CAD. Double reading was simulated by combining conventional readings in all 171 possible combinations of 19 radiologists, resulting in a total of 5301 cancer and 15 219 noncancer readings. Conventional single, DOUBLE and CAD readings were compared in terms of sensitivity and recall rate. Considering all 19 readings, cancer was identified in 190 or 248 of 589 readings (32.2 vs 42.1%, χ(2)=11.80, df=1, P<0.01) and recalls were 287 or 405 of 1691 readings (16.9 vs 23.9%, χ(2)=24.87, df=1, P<0.01) at CONV or CAD, respectively. When considering FN and MS cases separately, sensitivity at CONV or CAD was 50.2 or 62.6% (χ(2)=6.98, df=1, P=0.01) for FN and 22.3 or 30.7% (χ(2)=6.47, df=1, P=0.01) for MS cases, respectively. Computer-aided detection (average of 19 readings) was slightly and not significantly less sensitive (sensitivity: 42.1 vs 46.1%, χ(2)=3.24, df=1, P=0.07) but more specific (recall rate 23.9 vs 26.1%, χ(2)=3.8, df=1, P=0.04) as compared to DOUBLE (average of 171 readings). Average sensitivity for FN cases only was 62.6% for CAD and 64.8% for DOUBLE (χ(2)=0.32, df=1, P=0.58). Corresponding values for MS cases were 30.7% for CAD and 35.7% for DOUBLE (χ(2)=3.53, df=1, P=0.06). Compared to CONV, CAD allowed for improved sensitivity, though with reduced specificity, both effects being statistically significant. Computer-aided detection was almost as sensitive as DOUBLE but significantly more specific. Computer-aided detection might be used in the current practice to improve sensitivity of conventional single reading. Based on estimates of screening sensitivity and FN/MS interval cancer expected frequency, the absolute increase of screening sensitivity expected by introducing CAD-assisted reading may be estimated around 0.9%. The use of CAD as a possible surrogate to conventional DOUBLE needs to be confirmed by further studies, which should include a cost-effective analysis.
format Text
id pubmed-2394421
institution National Center for Biotechnology Information
language English
publishDate 2003
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-23944212009-09-10 Comparison of standard and double reading and computer-aided detection (CAD) of interval cancers at prior negative screening mammograms: blind review Ciatto, S Del Turco, M Rosselli Burke, P Visioli, C Paci, E Zappa, M Br J Cancer Clinical The study evaluates the role of computer-aided detection (CAD) in improving the detection of interval cancers as compared to conventional single (CONV) or double reading (DOUBLE). With this purpose, a set of 89 negative cases was seeded with 31 mammograms reported as negative and developing interval cancer in the following 2-year interval (false negative (FN)=11, minimal signs (MS)=20). A total of radiologists read the set with CONV and then with CAD. Overall, there were 589 cancer and 1691 noncancer readings with both CONV and CAD. Double reading was simulated by combining conventional readings in all 171 possible combinations of 19 radiologists, resulting in a total of 5301 cancer and 15 219 noncancer readings. Conventional single, DOUBLE and CAD readings were compared in terms of sensitivity and recall rate. Considering all 19 readings, cancer was identified in 190 or 248 of 589 readings (32.2 vs 42.1%, χ(2)=11.80, df=1, P<0.01) and recalls were 287 or 405 of 1691 readings (16.9 vs 23.9%, χ(2)=24.87, df=1, P<0.01) at CONV or CAD, respectively. When considering FN and MS cases separately, sensitivity at CONV or CAD was 50.2 or 62.6% (χ(2)=6.98, df=1, P=0.01) for FN and 22.3 or 30.7% (χ(2)=6.47, df=1, P=0.01) for MS cases, respectively. Computer-aided detection (average of 19 readings) was slightly and not significantly less sensitive (sensitivity: 42.1 vs 46.1%, χ(2)=3.24, df=1, P=0.07) but more specific (recall rate 23.9 vs 26.1%, χ(2)=3.8, df=1, P=0.04) as compared to DOUBLE (average of 171 readings). Average sensitivity for FN cases only was 62.6% for CAD and 64.8% for DOUBLE (χ(2)=0.32, df=1, P=0.58). Corresponding values for MS cases were 30.7% for CAD and 35.7% for DOUBLE (χ(2)=3.53, df=1, P=0.06). Compared to CONV, CAD allowed for improved sensitivity, though with reduced specificity, both effects being statistically significant. Computer-aided detection was almost as sensitive as DOUBLE but significantly more specific. Computer-aided detection might be used in the current practice to improve sensitivity of conventional single reading. Based on estimates of screening sensitivity and FN/MS interval cancer expected frequency, the absolute increase of screening sensitivity expected by introducing CAD-assisted reading may be estimated around 0.9%. The use of CAD as a possible surrogate to conventional DOUBLE needs to be confirmed by further studies, which should include a cost-effective analysis. Nature Publishing Group 2003-11-03 2003-10-28 /pmc/articles/PMC2394421/ /pubmed/14583763 http://dx.doi.org/10.1038/sj.bjc.6601356 Text en Copyright © 2003 Cancer Research UK https://creativecommons.org/licenses/by/4.0/This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material.If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit https://creativecommons.org/licenses/by/4.0/.
spellingShingle Clinical
Ciatto, S
Del Turco, M Rosselli
Burke, P
Visioli, C
Paci, E
Zappa, M
Comparison of standard and double reading and computer-aided detection (CAD) of interval cancers at prior negative screening mammograms: blind review
title Comparison of standard and double reading and computer-aided detection (CAD) of interval cancers at prior negative screening mammograms: blind review
title_full Comparison of standard and double reading and computer-aided detection (CAD) of interval cancers at prior negative screening mammograms: blind review
title_fullStr Comparison of standard and double reading and computer-aided detection (CAD) of interval cancers at prior negative screening mammograms: blind review
title_full_unstemmed Comparison of standard and double reading and computer-aided detection (CAD) of interval cancers at prior negative screening mammograms: blind review
title_short Comparison of standard and double reading and computer-aided detection (CAD) of interval cancers at prior negative screening mammograms: blind review
title_sort comparison of standard and double reading and computer-aided detection (cad) of interval cancers at prior negative screening mammograms: blind review
topic Clinical
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2394421/
https://www.ncbi.nlm.nih.gov/pubmed/14583763
http://dx.doi.org/10.1038/sj.bjc.6601356
work_keys_str_mv AT ciattos comparisonofstandardanddoublereadingandcomputeraideddetectioncadofintervalcancersatpriornegativescreeningmammogramsblindreview
AT delturcomrosselli comparisonofstandardanddoublereadingandcomputeraideddetectioncadofintervalcancersatpriornegativescreeningmammogramsblindreview
AT burkep comparisonofstandardanddoublereadingandcomputeraideddetectioncadofintervalcancersatpriornegativescreeningmammogramsblindreview
AT visiolic comparisonofstandardanddoublereadingandcomputeraideddetectioncadofintervalcancersatpriornegativescreeningmammogramsblindreview
AT pacie comparisonofstandardanddoublereadingandcomputeraideddetectioncadofintervalcancersatpriornegativescreeningmammogramsblindreview
AT zappam comparisonofstandardanddoublereadingandcomputeraideddetectioncadofintervalcancersatpriornegativescreeningmammogramsblindreview