Cargando…
X-ray beam stabilization at BL-17A, the protein microcrystallography beamline of the Photon Factory
BL-17A is a new structural biology beamline at the Photon Factory, Japan. The high-brilliance beam, derived from the new short-gap undulator (SGU#17), allows for unique protein crystallographic experiments such as data collection from microcrystals and structural determination using softer X-rays. H...
Autores principales: | , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
International Union of Crystallography
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2394782/ https://www.ncbi.nlm.nih.gov/pubmed/18421162 http://dx.doi.org/10.1107/S0909049507067118 |
_version_ | 1782155448711905280 |
---|---|
author | Igarashi, Noriyuki Ikuta, Kazuyuki Miyoshi, Toshinobu Matsugaki, Naohiro Yamada, Yusuke Yousef, Mohammad S. Wakatsuki, Soichi |
author_facet | Igarashi, Noriyuki Ikuta, Kazuyuki Miyoshi, Toshinobu Matsugaki, Naohiro Yamada, Yusuke Yousef, Mohammad S. Wakatsuki, Soichi |
author_sort | Igarashi, Noriyuki |
collection | PubMed |
description | BL-17A is a new structural biology beamline at the Photon Factory, Japan. The high-brilliance beam, derived from the new short-gap undulator (SGU#17), allows for unique protein crystallographic experiments such as data collection from microcrystals and structural determination using softer X-rays. However, microcrystal experiments require robust beam stability during data collection and minor fluctuations could not be ignored. Initially, significant beam instability was observed at BL-17A. The causes of the beam instability were investigated and its various sources identified. Subsequently, several effective countermeasures have been implemented, and the fluctuation of the beam intensity successfully suppressed to within 1%. Here the instability reduction techniques used at BL-17A are presented. |
format | Text |
id | pubmed-2394782 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2008 |
publisher | International Union of Crystallography |
record_format | MEDLINE/PubMed |
spelling | pubmed-23947822009-03-05 X-ray beam stabilization at BL-17A, the protein microcrystallography beamline of the Photon Factory Igarashi, Noriyuki Ikuta, Kazuyuki Miyoshi, Toshinobu Matsugaki, Naohiro Yamada, Yusuke Yousef, Mohammad S. Wakatsuki, Soichi J Synchrotron Radiat Diffraction Structural Biology BL-17A is a new structural biology beamline at the Photon Factory, Japan. The high-brilliance beam, derived from the new short-gap undulator (SGU#17), allows for unique protein crystallographic experiments such as data collection from microcrystals and structural determination using softer X-rays. However, microcrystal experiments require robust beam stability during data collection and minor fluctuations could not be ignored. Initially, significant beam instability was observed at BL-17A. The causes of the beam instability were investigated and its various sources identified. Subsequently, several effective countermeasures have been implemented, and the fluctuation of the beam intensity successfully suppressed to within 1%. Here the instability reduction techniques used at BL-17A are presented. International Union of Crystallography 2008-05-01 2008-04-18 /pmc/articles/PMC2394782/ /pubmed/18421162 http://dx.doi.org/10.1107/S0909049507067118 Text en © International Union of Crystallography 2008 http://journals.iucr.org/services/termsofuse.html This is an open-access article distributed under the terms described at http://journals.iucr.org/services/termsofuse.html. |
spellingShingle | Diffraction Structural Biology Igarashi, Noriyuki Ikuta, Kazuyuki Miyoshi, Toshinobu Matsugaki, Naohiro Yamada, Yusuke Yousef, Mohammad S. Wakatsuki, Soichi X-ray beam stabilization at BL-17A, the protein microcrystallography beamline of the Photon Factory |
title | X-ray beam stabilization at BL-17A, the protein microcrystallography beamline of the Photon Factory |
title_full | X-ray beam stabilization at BL-17A, the protein microcrystallography beamline of the Photon Factory |
title_fullStr | X-ray beam stabilization at BL-17A, the protein microcrystallography beamline of the Photon Factory |
title_full_unstemmed | X-ray beam stabilization at BL-17A, the protein microcrystallography beamline of the Photon Factory |
title_short | X-ray beam stabilization at BL-17A, the protein microcrystallography beamline of the Photon Factory |
title_sort | x-ray beam stabilization at bl-17a, the protein microcrystallography beamline of the photon factory |
topic | Diffraction Structural Biology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2394782/ https://www.ncbi.nlm.nih.gov/pubmed/18421162 http://dx.doi.org/10.1107/S0909049507067118 |
work_keys_str_mv | AT igarashinoriyuki xraybeamstabilizationatbl17atheproteinmicrocrystallographybeamlineofthephotonfactory AT ikutakazuyuki xraybeamstabilizationatbl17atheproteinmicrocrystallographybeamlineofthephotonfactory AT miyoshitoshinobu xraybeamstabilizationatbl17atheproteinmicrocrystallographybeamlineofthephotonfactory AT matsugakinaohiro xraybeamstabilizationatbl17atheproteinmicrocrystallographybeamlineofthephotonfactory AT yamadayusuke xraybeamstabilizationatbl17atheproteinmicrocrystallographybeamlineofthephotonfactory AT yousefmohammads xraybeamstabilizationatbl17atheproteinmicrocrystallographybeamlineofthephotonfactory AT wakatsukisoichi xraybeamstabilizationatbl17atheproteinmicrocrystallographybeamlineofthephotonfactory |