Cargando…

Why can pulmonary vein stenoses created by radiofrequency catheter ablation worsen during and after follow-up ? A potential explanation

BACKGROUND: Radiofrequency catheter ablation of excitation foci inside pulmonary veins (PV) generates stenoses that can become quite severe during or after the follow-up period. Since severe PV stenoses have most often disastrous consequences, it would be important to know the underlying mechanism o...

Descripción completa

Detalles Bibliográficos
Autores principales: Doriot, Pierre-André, Dorsaz, Pierre-André, Shah, Dipen Chandrakant
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2408572/
https://www.ncbi.nlm.nih.gov/pubmed/18457581
http://dx.doi.org/10.1186/1749-8090-3-24
_version_ 1782155674799570944
author Doriot, Pierre-André
Dorsaz, Pierre-André
Shah, Dipen Chandrakant
author_facet Doriot, Pierre-André
Dorsaz, Pierre-André
Shah, Dipen Chandrakant
author_sort Doriot, Pierre-André
collection PubMed
description BACKGROUND: Radiofrequency catheter ablation of excitation foci inside pulmonary veins (PV) generates stenoses that can become quite severe during or after the follow-up period. Since severe PV stenoses have most often disastrous consequences, it would be important to know the underlying mechanism of this temporal evolution. The present study proposes a potential explanation based on mechanical considerations. METHODS: we have used a mathematical-physical model to examine the cyclic increase in axial wall stress induced in the proximal (= upstream), non-stenosed segment of a stenosed pulmonary vein during the forward flow phases. In a representative example, the value of this increase at peak flow was calculated for diameter stenoses (DS) ranging from 1 to 99%. RESULTS: The increase becomes appreciable at a DS of roughly 30% and rise then strongly with further increasing DS value. At high DS values (e.g. > 90%) the increase is approximately twice the value of the axial stress present in the PV during the zero-flow phase. CONCLUSION: Since abnormal wall stresses are known to induce damages and abnormal biological processes (e.g., endothelium tears, elastic membrane fragmentations, matrix secretion, myofibroblast generation, etc) in the vessel wall, it seems plausible that the supplementary axial stress experienced cyclically by the stenotic and the proximal segments of the PV is responsible for the often observed progressive reduction of the vessel lumen after healing of the ablation injury. In the light of this model, the only potentially effective therapy in these cases would be to reduce the DS as strongly as possible. This implies most probably stenting or surgery.
format Text
id pubmed-2408572
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-24085722008-06-02 Why can pulmonary vein stenoses created by radiofrequency catheter ablation worsen during and after follow-up ? A potential explanation Doriot, Pierre-André Dorsaz, Pierre-André Shah, Dipen Chandrakant J Cardiothorac Surg Research Article BACKGROUND: Radiofrequency catheter ablation of excitation foci inside pulmonary veins (PV) generates stenoses that can become quite severe during or after the follow-up period. Since severe PV stenoses have most often disastrous consequences, it would be important to know the underlying mechanism of this temporal evolution. The present study proposes a potential explanation based on mechanical considerations. METHODS: we have used a mathematical-physical model to examine the cyclic increase in axial wall stress induced in the proximal (= upstream), non-stenosed segment of a stenosed pulmonary vein during the forward flow phases. In a representative example, the value of this increase at peak flow was calculated for diameter stenoses (DS) ranging from 1 to 99%. RESULTS: The increase becomes appreciable at a DS of roughly 30% and rise then strongly with further increasing DS value. At high DS values (e.g. > 90%) the increase is approximately twice the value of the axial stress present in the PV during the zero-flow phase. CONCLUSION: Since abnormal wall stresses are known to induce damages and abnormal biological processes (e.g., endothelium tears, elastic membrane fragmentations, matrix secretion, myofibroblast generation, etc) in the vessel wall, it seems plausible that the supplementary axial stress experienced cyclically by the stenotic and the proximal segments of the PV is responsible for the often observed progressive reduction of the vessel lumen after healing of the ablation injury. In the light of this model, the only potentially effective therapy in these cases would be to reduce the DS as strongly as possible. This implies most probably stenting or surgery. BioMed Central 2008-05-05 /pmc/articles/PMC2408572/ /pubmed/18457581 http://dx.doi.org/10.1186/1749-8090-3-24 Text en Copyright © 2008 Doriot et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Doriot, Pierre-André
Dorsaz, Pierre-André
Shah, Dipen Chandrakant
Why can pulmonary vein stenoses created by radiofrequency catheter ablation worsen during and after follow-up ? A potential explanation
title Why can pulmonary vein stenoses created by radiofrequency catheter ablation worsen during and after follow-up ? A potential explanation
title_full Why can pulmonary vein stenoses created by radiofrequency catheter ablation worsen during and after follow-up ? A potential explanation
title_fullStr Why can pulmonary vein stenoses created by radiofrequency catheter ablation worsen during and after follow-up ? A potential explanation
title_full_unstemmed Why can pulmonary vein stenoses created by radiofrequency catheter ablation worsen during and after follow-up ? A potential explanation
title_short Why can pulmonary vein stenoses created by radiofrequency catheter ablation worsen during and after follow-up ? A potential explanation
title_sort why can pulmonary vein stenoses created by radiofrequency catheter ablation worsen during and after follow-up ? a potential explanation
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2408572/
https://www.ncbi.nlm.nih.gov/pubmed/18457581
http://dx.doi.org/10.1186/1749-8090-3-24
work_keys_str_mv AT doriotpierreandre whycanpulmonaryveinstenosescreatedbyradiofrequencycatheterablationworsenduringandafterfollowupapotentialexplanation
AT dorsazpierreandre whycanpulmonaryveinstenosescreatedbyradiofrequencycatheterablationworsenduringandafterfollowupapotentialexplanation
AT shahdipenchandrakant whycanpulmonaryveinstenosescreatedbyradiofrequencycatheterablationworsenduringandafterfollowupapotentialexplanation