Cargando…
Affordable pediatric CD4 counting by flow cytometry in Malawi
BACKGROUND: Rapid expansion of antiretroviral therapy in Malawi has occurred in the relative absence of suitable pediatric CD4 counting facilities. We have recently validated in adults a simplified affordable flow cytometric CD4 counting method, the Blantyre count. There is a need for this technolog...
Autores principales: | , , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Wiley Subscription Services, Inc., A Wiley Company
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2408853/ https://www.ncbi.nlm.nih.gov/pubmed/18307249 http://dx.doi.org/10.1002/cyto.b.20411 |
_version_ | 1782155715240001536 |
---|---|
author | MacLennan, Calman A Dzumani, Felix Namarika, Alinane Moons, Peter Senga, Edward Molyneux, Malcolm E Drayson, Mark T Bunn, James E G |
author_facet | MacLennan, Calman A Dzumani, Felix Namarika, Alinane Moons, Peter Senga, Edward Molyneux, Malcolm E Drayson, Mark T Bunn, James E G |
author_sort | MacLennan, Calman A |
collection | PubMed |
description | BACKGROUND: Rapid expansion of antiretroviral therapy in Malawi has occurred in the relative absence of suitable pediatric CD4 counting facilities. We have recently validated in adults a simplified affordable flow cytometric CD4 counting method, the Blantyre count. There is a need for this technology to transfer to government laboratories run by local staff, and to be validated in children, where %CD4/lymphocyte values are required. METHODS: We assessed agreement of %CD4/lymphocyte values determined by the Blantyre count and Panleucogate methods on an EPICS XL-MCL flow cytometer on 113 venous blood samples from HIV-seropositive children in Blantyre, Malawi. All assays were performed by two Malawian laboratory technicians. RESULTS: Overall bias between the two methods was −0.13% (95% CI −0.37 to 0.11) and limits of agreement were −2.69 to 2.43% (95% CI −3.11 to −2.27 and 2.01 to 2.85). Limits of agreement were within −3.00 and 3.00 for each laboratory technician. Coefficient of variation for the Blantyre count assay was 2.0% and samples showed good stability over 5 days. CONCLUSIONS: The Blantyre count method can accurately determine %CD4/lymphocyte values in blood of HIV-seropositive children on an EPIC XL-MCL flow cytometer at a reagent cost of US $0.21 per test or less. The assay can be competently carried out by local laboratory technicians. |
format | Text |
id | pubmed-2408853 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2008 |
publisher | Wiley Subscription Services, Inc., A Wiley Company |
record_format | MEDLINE/PubMed |
spelling | pubmed-24088532008-06-02 Affordable pediatric CD4 counting by flow cytometry in Malawi MacLennan, Calman A Dzumani, Felix Namarika, Alinane Moons, Peter Senga, Edward Molyneux, Malcolm E Drayson, Mark T Bunn, James E G Cytometry B Clin Cytom Original Article BACKGROUND: Rapid expansion of antiretroviral therapy in Malawi has occurred in the relative absence of suitable pediatric CD4 counting facilities. We have recently validated in adults a simplified affordable flow cytometric CD4 counting method, the Blantyre count. There is a need for this technology to transfer to government laboratories run by local staff, and to be validated in children, where %CD4/lymphocyte values are required. METHODS: We assessed agreement of %CD4/lymphocyte values determined by the Blantyre count and Panleucogate methods on an EPICS XL-MCL flow cytometer on 113 venous blood samples from HIV-seropositive children in Blantyre, Malawi. All assays were performed by two Malawian laboratory technicians. RESULTS: Overall bias between the two methods was −0.13% (95% CI −0.37 to 0.11) and limits of agreement were −2.69 to 2.43% (95% CI −3.11 to −2.27 and 2.01 to 2.85). Limits of agreement were within −3.00 and 3.00 for each laboratory technician. Coefficient of variation for the Blantyre count assay was 2.0% and samples showed good stability over 5 days. CONCLUSIONS: The Blantyre count method can accurately determine %CD4/lymphocyte values in blood of HIV-seropositive children on an EPIC XL-MCL flow cytometer at a reagent cost of US $0.21 per test or less. The assay can be competently carried out by local laboratory technicians. Wiley Subscription Services, Inc., A Wiley Company 2008 2008-02-28 /pmc/articles/PMC2408853/ /pubmed/18307249 http://dx.doi.org/10.1002/cyto.b.20411 Text en Copyright © 2008 Clinical Cytometry Society http://creativecommons.org/licenses/by/2.5/ Re-use of this article is permitted in accordance with the Creative Commons Deed, Attribution 2.5, which does not permit commercial exploitation. |
spellingShingle | Original Article MacLennan, Calman A Dzumani, Felix Namarika, Alinane Moons, Peter Senga, Edward Molyneux, Malcolm E Drayson, Mark T Bunn, James E G Affordable pediatric CD4 counting by flow cytometry in Malawi |
title | Affordable pediatric CD4 counting by flow cytometry in Malawi |
title_full | Affordable pediatric CD4 counting by flow cytometry in Malawi |
title_fullStr | Affordable pediatric CD4 counting by flow cytometry in Malawi |
title_full_unstemmed | Affordable pediatric CD4 counting by flow cytometry in Malawi |
title_short | Affordable pediatric CD4 counting by flow cytometry in Malawi |
title_sort | affordable pediatric cd4 counting by flow cytometry in malawi |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2408853/ https://www.ncbi.nlm.nih.gov/pubmed/18307249 http://dx.doi.org/10.1002/cyto.b.20411 |
work_keys_str_mv | AT maclennancalmana affordablepediatriccd4countingbyflowcytometryinmalawi AT dzumanifelix affordablepediatriccd4countingbyflowcytometryinmalawi AT namarikaalinane affordablepediatriccd4countingbyflowcytometryinmalawi AT moonspeter affordablepediatriccd4countingbyflowcytometryinmalawi AT sengaedward affordablepediatriccd4countingbyflowcytometryinmalawi AT molyneuxmalcolme affordablepediatriccd4countingbyflowcytometryinmalawi AT draysonmarkt affordablepediatriccd4countingbyflowcytometryinmalawi AT bunnjameseg affordablepediatriccd4countingbyflowcytometryinmalawi |