Cargando…

Affordable pediatric CD4 counting by flow cytometry in Malawi

BACKGROUND: Rapid expansion of antiretroviral therapy in Malawi has occurred in the relative absence of suitable pediatric CD4 counting facilities. We have recently validated in adults a simplified affordable flow cytometric CD4 counting method, the Blantyre count. There is a need for this technolog...

Descripción completa

Detalles Bibliográficos
Autores principales: MacLennan, Calman A, Dzumani, Felix, Namarika, Alinane, Moons, Peter, Senga, Edward, Molyneux, Malcolm E, Drayson, Mark T, Bunn, James E G
Formato: Texto
Lenguaje:English
Publicado: Wiley Subscription Services, Inc., A Wiley Company 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2408853/
https://www.ncbi.nlm.nih.gov/pubmed/18307249
http://dx.doi.org/10.1002/cyto.b.20411
_version_ 1782155715240001536
author MacLennan, Calman A
Dzumani, Felix
Namarika, Alinane
Moons, Peter
Senga, Edward
Molyneux, Malcolm E
Drayson, Mark T
Bunn, James E G
author_facet MacLennan, Calman A
Dzumani, Felix
Namarika, Alinane
Moons, Peter
Senga, Edward
Molyneux, Malcolm E
Drayson, Mark T
Bunn, James E G
author_sort MacLennan, Calman A
collection PubMed
description BACKGROUND: Rapid expansion of antiretroviral therapy in Malawi has occurred in the relative absence of suitable pediatric CD4 counting facilities. We have recently validated in adults a simplified affordable flow cytometric CD4 counting method, the Blantyre count. There is a need for this technology to transfer to government laboratories run by local staff, and to be validated in children, where %CD4/lymphocyte values are required. METHODS: We assessed agreement of %CD4/lymphocyte values determined by the Blantyre count and Panleucogate methods on an EPICS XL-MCL flow cytometer on 113 venous blood samples from HIV-seropositive children in Blantyre, Malawi. All assays were performed by two Malawian laboratory technicians. RESULTS: Overall bias between the two methods was −0.13% (95% CI −0.37 to 0.11) and limits of agreement were −2.69 to 2.43% (95% CI −3.11 to −2.27 and 2.01 to 2.85). Limits of agreement were within −3.00 and 3.00 for each laboratory technician. Coefficient of variation for the Blantyre count assay was 2.0% and samples showed good stability over 5 days. CONCLUSIONS: The Blantyre count method can accurately determine %CD4/lymphocyte values in blood of HIV-seropositive children on an EPIC XL-MCL flow cytometer at a reagent cost of US $0.21 per test or less. The assay can be competently carried out by local laboratory technicians.
format Text
id pubmed-2408853
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher Wiley Subscription Services, Inc., A Wiley Company
record_format MEDLINE/PubMed
spelling pubmed-24088532008-06-02 Affordable pediatric CD4 counting by flow cytometry in Malawi MacLennan, Calman A Dzumani, Felix Namarika, Alinane Moons, Peter Senga, Edward Molyneux, Malcolm E Drayson, Mark T Bunn, James E G Cytometry B Clin Cytom Original Article BACKGROUND: Rapid expansion of antiretroviral therapy in Malawi has occurred in the relative absence of suitable pediatric CD4 counting facilities. We have recently validated in adults a simplified affordable flow cytometric CD4 counting method, the Blantyre count. There is a need for this technology to transfer to government laboratories run by local staff, and to be validated in children, where %CD4/lymphocyte values are required. METHODS: We assessed agreement of %CD4/lymphocyte values determined by the Blantyre count and Panleucogate methods on an EPICS XL-MCL flow cytometer on 113 venous blood samples from HIV-seropositive children in Blantyre, Malawi. All assays were performed by two Malawian laboratory technicians. RESULTS: Overall bias between the two methods was −0.13% (95% CI −0.37 to 0.11) and limits of agreement were −2.69 to 2.43% (95% CI −3.11 to −2.27 and 2.01 to 2.85). Limits of agreement were within −3.00 and 3.00 for each laboratory technician. Coefficient of variation for the Blantyre count assay was 2.0% and samples showed good stability over 5 days. CONCLUSIONS: The Blantyre count method can accurately determine %CD4/lymphocyte values in blood of HIV-seropositive children on an EPIC XL-MCL flow cytometer at a reagent cost of US $0.21 per test or less. The assay can be competently carried out by local laboratory technicians. Wiley Subscription Services, Inc., A Wiley Company 2008 2008-02-28 /pmc/articles/PMC2408853/ /pubmed/18307249 http://dx.doi.org/10.1002/cyto.b.20411 Text en Copyright © 2008 Clinical Cytometry Society http://creativecommons.org/licenses/by/2.5/ Re-use of this article is permitted in accordance with the Creative Commons Deed, Attribution 2.5, which does not permit commercial exploitation.
spellingShingle Original Article
MacLennan, Calman A
Dzumani, Felix
Namarika, Alinane
Moons, Peter
Senga, Edward
Molyneux, Malcolm E
Drayson, Mark T
Bunn, James E G
Affordable pediatric CD4 counting by flow cytometry in Malawi
title Affordable pediatric CD4 counting by flow cytometry in Malawi
title_full Affordable pediatric CD4 counting by flow cytometry in Malawi
title_fullStr Affordable pediatric CD4 counting by flow cytometry in Malawi
title_full_unstemmed Affordable pediatric CD4 counting by flow cytometry in Malawi
title_short Affordable pediatric CD4 counting by flow cytometry in Malawi
title_sort affordable pediatric cd4 counting by flow cytometry in malawi
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2408853/
https://www.ncbi.nlm.nih.gov/pubmed/18307249
http://dx.doi.org/10.1002/cyto.b.20411
work_keys_str_mv AT maclennancalmana affordablepediatriccd4countingbyflowcytometryinmalawi
AT dzumanifelix affordablepediatriccd4countingbyflowcytometryinmalawi
AT namarikaalinane affordablepediatriccd4countingbyflowcytometryinmalawi
AT moonspeter affordablepediatriccd4countingbyflowcytometryinmalawi
AT sengaedward affordablepediatriccd4countingbyflowcytometryinmalawi
AT molyneuxmalcolme affordablepediatriccd4countingbyflowcytometryinmalawi
AT draysonmarkt affordablepediatriccd4countingbyflowcytometryinmalawi
AT bunnjameseg affordablepediatriccd4countingbyflowcytometryinmalawi