Cargando…
Successful closed manipulation of a pure lateral traumatic dislocation of the elbow joint using a modified Stimson's technique: a case report
INTRODUCTION: Pure lateral elbow dislocation is rare, and a successful closed reduction is even rarer. Reduction can be hindered by swelling, soft tissue interposition or associated fractures. CASE PRESENTATION: We present a pure lateral traumatic dislocation of the elbow joint in a 40-year-old man....
Autores principales: | , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2409352/ https://www.ncbi.nlm.nih.gov/pubmed/18498622 http://dx.doi.org/10.1186/1752-1947-2-170 |
_version_ | 1782155756835962880 |
---|---|
author | Khan, Sameer K Chopra, Rajat Chakravarty, Debasis |
author_facet | Khan, Sameer K Chopra, Rajat Chakravarty, Debasis |
author_sort | Khan, Sameer K |
collection | PubMed |
description | INTRODUCTION: Pure lateral elbow dislocation is rare, and a successful closed reduction is even rarer. Reduction can be hindered by swelling, soft tissue interposition or associated fractures. CASE PRESENTATION: We present a pure lateral traumatic dislocation of the elbow joint in a 40-year-old man. This was successfully manipulated and reduced in casualty using a modification of the gravity-aided 'hanging arm' technique originally described for shoulder dislocations by Stimson. CONCLUSION: We strongly recommend the use of this simple technique in these rare yet difficult injuries, in order to avoid potential complications with general anaesthesia and surgery. |
format | Text |
id | pubmed-2409352 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2008 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-24093522008-06-04 Successful closed manipulation of a pure lateral traumatic dislocation of the elbow joint using a modified Stimson's technique: a case report Khan, Sameer K Chopra, Rajat Chakravarty, Debasis J Med Case Reports Case Report INTRODUCTION: Pure lateral elbow dislocation is rare, and a successful closed reduction is even rarer. Reduction can be hindered by swelling, soft tissue interposition or associated fractures. CASE PRESENTATION: We present a pure lateral traumatic dislocation of the elbow joint in a 40-year-old man. This was successfully manipulated and reduced in casualty using a modification of the gravity-aided 'hanging arm' technique originally described for shoulder dislocations by Stimson. CONCLUSION: We strongly recommend the use of this simple technique in these rare yet difficult injuries, in order to avoid potential complications with general anaesthesia and surgery. BioMed Central 2008-05-22 /pmc/articles/PMC2409352/ /pubmed/18498622 http://dx.doi.org/10.1186/1752-1947-2-170 Text en Copyright © 2008 Khan et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Khan, Sameer K Chopra, Rajat Chakravarty, Debasis Successful closed manipulation of a pure lateral traumatic dislocation of the elbow joint using a modified Stimson's technique: a case report |
title | Successful closed manipulation of a pure lateral traumatic dislocation of the elbow joint using a modified Stimson's technique: a case report |
title_full | Successful closed manipulation of a pure lateral traumatic dislocation of the elbow joint using a modified Stimson's technique: a case report |
title_fullStr | Successful closed manipulation of a pure lateral traumatic dislocation of the elbow joint using a modified Stimson's technique: a case report |
title_full_unstemmed | Successful closed manipulation of a pure lateral traumatic dislocation of the elbow joint using a modified Stimson's technique: a case report |
title_short | Successful closed manipulation of a pure lateral traumatic dislocation of the elbow joint using a modified Stimson's technique: a case report |
title_sort | successful closed manipulation of a pure lateral traumatic dislocation of the elbow joint using a modified stimson's technique: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2409352/ https://www.ncbi.nlm.nih.gov/pubmed/18498622 http://dx.doi.org/10.1186/1752-1947-2-170 |
work_keys_str_mv | AT khansameerk successfulclosedmanipulationofapurelateraltraumaticdislocationoftheelbowjointusingamodifiedstimsonstechniqueacasereport AT choprarajat successfulclosedmanipulationofapurelateraltraumaticdislocationoftheelbowjointusingamodifiedstimsonstechniqueacasereport AT chakravartydebasis successfulclosedmanipulationofapurelateraltraumaticdislocationoftheelbowjointusingamodifiedstimsonstechniqueacasereport |