Cargando…
A systematic review of mobility instruments and their measurement properties for older acute medical patients
BACKGROUND: Independent mobility is a key factor in determining readiness for discharge for older patients following acute hospitalisation and has also been identified as a predictor of many important outcomes for this patient group. This review aimed to identify a physical performance instrument th...
Autores principales: | , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2430553/ https://www.ncbi.nlm.nih.gov/pubmed/18533045 http://dx.doi.org/10.1186/1477-7525-6-44 |
_version_ | 1782156406197059584 |
---|---|
author | de Morton, Natalie A Berlowitz, David J Keating, Jennifer L |
author_facet | de Morton, Natalie A Berlowitz, David J Keating, Jennifer L |
author_sort | de Morton, Natalie A |
collection | PubMed |
description | BACKGROUND: Independent mobility is a key factor in determining readiness for discharge for older patients following acute hospitalisation and has also been identified as a predictor of many important outcomes for this patient group. This review aimed to identify a physical performance instrument that is not disease specific that has the properties required to accurately measure and monitor the mobility of older medical patients in the acute hospital setting. METHODS: Databases initially searched were Medline, Cinahl, Embase, Cochrane Database of Systematic Reviews and the Cochrane Central Register of Controlled Trials without language restriction or limits on year of publication until July 2005. After analysis of this yield, a second step was the systematic search of Medline, Cinahl and Embase until August 2005 for evidence of the clinical utility of each potentially suitable instrument. Reports were included in this review if instruments described had face validity for measuring from bed bound to independent levels of ambulation, the items were suitable for application in an acute hospital setting and the instrument required observation (rather than self-report) of physical performance. Evidence of the clinical utility of each potentially suitable instrument was considered if data on measurement properties were reported. RESULTS: Three instruments, the Elderly Mobility Scale (EMS), Hierarchical Assessment of Balance and Mobility (HABAM) and the Physical Performance Mobility Examination (PPME) were identified as potentially relevant. Clinimetric evaluation indicated that the HABAM has the most desirable properties of these three instruments. However, the HABAM has the limitation of a ceiling effect in an older acute medical patient population and reliability and minimally clinically important difference (MCID) estimates have not been reported for the Rasch refined HABAM. These limitations support the proposal that a new mobility instrument is required for older acute medical patients. CONCLUSION: No existing instrument has the properties required to accurately measure and monitor mobility of older acute medical patients. |
format | Text |
id | pubmed-2430553 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2008 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-24305532008-06-18 A systematic review of mobility instruments and their measurement properties for older acute medical patients de Morton, Natalie A Berlowitz, David J Keating, Jennifer L Health Qual Life Outcomes Review BACKGROUND: Independent mobility is a key factor in determining readiness for discharge for older patients following acute hospitalisation and has also been identified as a predictor of many important outcomes for this patient group. This review aimed to identify a physical performance instrument that is not disease specific that has the properties required to accurately measure and monitor the mobility of older medical patients in the acute hospital setting. METHODS: Databases initially searched were Medline, Cinahl, Embase, Cochrane Database of Systematic Reviews and the Cochrane Central Register of Controlled Trials without language restriction or limits on year of publication until July 2005. After analysis of this yield, a second step was the systematic search of Medline, Cinahl and Embase until August 2005 for evidence of the clinical utility of each potentially suitable instrument. Reports were included in this review if instruments described had face validity for measuring from bed bound to independent levels of ambulation, the items were suitable for application in an acute hospital setting and the instrument required observation (rather than self-report) of physical performance. Evidence of the clinical utility of each potentially suitable instrument was considered if data on measurement properties were reported. RESULTS: Three instruments, the Elderly Mobility Scale (EMS), Hierarchical Assessment of Balance and Mobility (HABAM) and the Physical Performance Mobility Examination (PPME) were identified as potentially relevant. Clinimetric evaluation indicated that the HABAM has the most desirable properties of these three instruments. However, the HABAM has the limitation of a ceiling effect in an older acute medical patient population and reliability and minimally clinically important difference (MCID) estimates have not been reported for the Rasch refined HABAM. These limitations support the proposal that a new mobility instrument is required for older acute medical patients. CONCLUSION: No existing instrument has the properties required to accurately measure and monitor mobility of older acute medical patients. BioMed Central 2008-06-05 /pmc/articles/PMC2430553/ /pubmed/18533045 http://dx.doi.org/10.1186/1477-7525-6-44 Text en Copyright © 2008 de Morton et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Review de Morton, Natalie A Berlowitz, David J Keating, Jennifer L A systematic review of mobility instruments and their measurement properties for older acute medical patients |
title | A systematic review of mobility instruments and their measurement properties for older acute medical patients |
title_full | A systematic review of mobility instruments and their measurement properties for older acute medical patients |
title_fullStr | A systematic review of mobility instruments and their measurement properties for older acute medical patients |
title_full_unstemmed | A systematic review of mobility instruments and their measurement properties for older acute medical patients |
title_short | A systematic review of mobility instruments and their measurement properties for older acute medical patients |
title_sort | systematic review of mobility instruments and their measurement properties for older acute medical patients |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2430553/ https://www.ncbi.nlm.nih.gov/pubmed/18533045 http://dx.doi.org/10.1186/1477-7525-6-44 |
work_keys_str_mv | AT demortonnataliea asystematicreviewofmobilityinstrumentsandtheirmeasurementpropertiesforolderacutemedicalpatients AT berlowitzdavidj asystematicreviewofmobilityinstrumentsandtheirmeasurementpropertiesforolderacutemedicalpatients AT keatingjenniferl asystematicreviewofmobilityinstrumentsandtheirmeasurementpropertiesforolderacutemedicalpatients AT demortonnataliea systematicreviewofmobilityinstrumentsandtheirmeasurementpropertiesforolderacutemedicalpatients AT berlowitzdavidj systematicreviewofmobilityinstrumentsandtheirmeasurementpropertiesforolderacutemedicalpatients AT keatingjenniferl systematicreviewofmobilityinstrumentsandtheirmeasurementpropertiesforolderacutemedicalpatients |