Skin avulsion injury during endotracheal tube extubation – case report of an unusual complication
We report a geriatric case with a full-thickness skin avulsion injury during extubation due to a tube securing tape used to fixate the endotracheal tube. The avulsed skin was sutured back to its original place. Based on this single geriatric patient, we recommend anesthesiologists/anesthetists and s...
Autores principales: | Yilmaz, Berkhan, Colakoglu, Kutay, Gurunluoglu, Raffi |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2438342/ https://www.ncbi.nlm.nih.gov/pubmed/18495010 http://dx.doi.org/10.1186/1754-9493-2-12 |
Ejemplares similares
-
Extubation and Changing Endotracheal Tubes
por: Cooper, Richard M.
Publicado: (2007) -
Accidental intraoperative avulsion of external inflation tubing of armored endotracheal tube
por: Bhandari, Shyam, et al.
Publicado: (2012) -
Difficult Extubation Due to Failure of an Endotracheal Tube Cuff Deflation
por: Suman, Sourabh, et al.
Publicado: (2011) -
Resistance of endotracheal tubes measured after extubation in ICU patients
por: Baboi, L, et al.
Publicado: (2015) -
A difficult extubation: Endotracheal tube ensnarement by a Kirschner wire
por: Davila, Victor R, et al.
Publicado: (2015)