A simplified guide ruler from numeric table method in doing rotational osteotomy
BACKGROUND: Čobeljić et al. recently reported a numeric table method to provide precise rotational osteotomy which is a well established orthopaedic procedure. The numeric table requires four pages in length that is rather inconvenient during performing an osteotomy operation. METHODS: We thus devel...
Autores principales: | , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2440753/ https://www.ncbi.nlm.nih.gov/pubmed/18557999 http://dx.doi.org/10.1186/1471-2474-9-87 |
Sumario: | BACKGROUND: Čobeljić et al. recently reported a numeric table method to provide precise rotational osteotomy which is a well established orthopaedic procedure. The numeric table requires four pages in length that is rather inconvenient during performing an osteotomy operation. METHODS: We thus develop our own method by summarizing the data of the four-page table into a small ruler, which is easy to carry and use in operation room. An electrical version of this ruler is also available. We also build a computer model to verify Čobeljić et al. method. RESULTS: The error of Čobeljić et al. is between -37% to 16% (mean ± SD = -6% ± 9%). We verify our ruler by calculating the absolute difference between our method and that of Čobeljić et al. The difference is less than 0.1 mm. CONCLUSION: Our ruler is convenient for practical use for the rotational osteotomy procedure with equal precision. Further clinical verification is needed to justify its real significance. |
---|