Cargando…

A simplified guide ruler from numeric table method in doing rotational osteotomy

BACKGROUND: Čobeljić et al. recently reported a numeric table method to provide precise rotational osteotomy which is a well established orthopaedic procedure. The numeric table requires four pages in length that is rather inconvenient during performing an osteotomy operation. METHODS: We thus devel...

Descripción completa

Detalles Bibliográficos
Autores principales: Liaw, Chen-Kun, Yang, Rong-Sen, Hou, Sheng-Mou, Wu, Tai-Yin, Fuh, Chiou-Shann
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2440753/
https://www.ncbi.nlm.nih.gov/pubmed/18557999
http://dx.doi.org/10.1186/1471-2474-9-87
_version_ 1782156572907012096
author Liaw, Chen-Kun
Yang, Rong-Sen
Hou, Sheng-Mou
Wu, Tai-Yin
Fuh, Chiou-Shann
author_facet Liaw, Chen-Kun
Yang, Rong-Sen
Hou, Sheng-Mou
Wu, Tai-Yin
Fuh, Chiou-Shann
author_sort Liaw, Chen-Kun
collection PubMed
description BACKGROUND: Čobeljić et al. recently reported a numeric table method to provide precise rotational osteotomy which is a well established orthopaedic procedure. The numeric table requires four pages in length that is rather inconvenient during performing an osteotomy operation. METHODS: We thus develop our own method by summarizing the data of the four-page table into a small ruler, which is easy to carry and use in operation room. An electrical version of this ruler is also available. We also build a computer model to verify Čobeljić et al. method. RESULTS: The error of Čobeljić et al. is between -37% to 16% (mean ± SD = -6% ± 9%). We verify our ruler by calculating the absolute difference between our method and that of Čobeljić et al. The difference is less than 0.1 mm. CONCLUSION: Our ruler is convenient for practical use for the rotational osteotomy procedure with equal precision. Further clinical verification is needed to justify its real significance.
format Text
id pubmed-2440753
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-24407532008-06-27 A simplified guide ruler from numeric table method in doing rotational osteotomy Liaw, Chen-Kun Yang, Rong-Sen Hou, Sheng-Mou Wu, Tai-Yin Fuh, Chiou-Shann BMC Musculoskelet Disord Correspondence BACKGROUND: Čobeljić et al. recently reported a numeric table method to provide precise rotational osteotomy which is a well established orthopaedic procedure. The numeric table requires four pages in length that is rather inconvenient during performing an osteotomy operation. METHODS: We thus develop our own method by summarizing the data of the four-page table into a small ruler, which is easy to carry and use in operation room. An electrical version of this ruler is also available. We also build a computer model to verify Čobeljić et al. method. RESULTS: The error of Čobeljić et al. is between -37% to 16% (mean ± SD = -6% ± 9%). We verify our ruler by calculating the absolute difference between our method and that of Čobeljić et al. The difference is less than 0.1 mm. CONCLUSION: Our ruler is convenient for practical use for the rotational osteotomy procedure with equal precision. Further clinical verification is needed to justify its real significance. BioMed Central 2008-06-16 /pmc/articles/PMC2440753/ /pubmed/18557999 http://dx.doi.org/10.1186/1471-2474-9-87 Text en Copyright © 2008 Liaw et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Correspondence
Liaw, Chen-Kun
Yang, Rong-Sen
Hou, Sheng-Mou
Wu, Tai-Yin
Fuh, Chiou-Shann
A simplified guide ruler from numeric table method in doing rotational osteotomy
title A simplified guide ruler from numeric table method in doing rotational osteotomy
title_full A simplified guide ruler from numeric table method in doing rotational osteotomy
title_fullStr A simplified guide ruler from numeric table method in doing rotational osteotomy
title_full_unstemmed A simplified guide ruler from numeric table method in doing rotational osteotomy
title_short A simplified guide ruler from numeric table method in doing rotational osteotomy
title_sort simplified guide ruler from numeric table method in doing rotational osteotomy
topic Correspondence
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2440753/
https://www.ncbi.nlm.nih.gov/pubmed/18557999
http://dx.doi.org/10.1186/1471-2474-9-87
work_keys_str_mv AT liawchenkun asimplifiedguiderulerfromnumerictablemethodindoingrotationalosteotomy
AT yangrongsen asimplifiedguiderulerfromnumerictablemethodindoingrotationalosteotomy
AT houshengmou asimplifiedguiderulerfromnumerictablemethodindoingrotationalosteotomy
AT wutaiyin asimplifiedguiderulerfromnumerictablemethodindoingrotationalosteotomy
AT fuhchioushann asimplifiedguiderulerfromnumerictablemethodindoingrotationalosteotomy
AT liawchenkun simplifiedguiderulerfromnumerictablemethodindoingrotationalosteotomy
AT yangrongsen simplifiedguiderulerfromnumerictablemethodindoingrotationalosteotomy
AT houshengmou simplifiedguiderulerfromnumerictablemethodindoingrotationalosteotomy
AT wutaiyin simplifiedguiderulerfromnumerictablemethodindoingrotationalosteotomy
AT fuhchioushann simplifiedguiderulerfromnumerictablemethodindoingrotationalosteotomy