Cargando…
Hepatic Resection Using a Water Jet Dissector
The mortality and morbidity in major hepatic resection is often related to hemorrhage. A high pressure, high velocity water jet has been developed and has been utilized to assist in hepatic parenchymal transection. Sixty-seven major hepatic resections were performed for solid hepatic tumors. The tis...
Autores principales: | , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
1993
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2443048/ https://www.ncbi.nlm.nih.gov/pubmed/8387808 http://dx.doi.org/10.1155/1993/82362 |
Sumario: | The mortality and morbidity in major hepatic resection is often related to hemorrhage. A high pressure, high velocity water jet has been developed and has been utilized to assist in hepatic parenchymal transection. Sixty-seven major hepatic resections were performed for solid hepatic tumors. The tissue fracture technique was used in 51 patients (76%), and the water jet dissector was used predominantly in 16 patients (24%). The extent of hepatic resection using each technique was similar. The results showed no difference in operative duration (p = .499). The mean estimated blood loss using the water jet was 1386 ml, and tissue fracture technique 2450 ml (p = .217). Transfusion requirements were less in the water jet group (mean 2.0 units) compared to the tissue fracture group (mean 5.2 units); (p = .023). Results obtained with the new water dissector are encouraging. The preliminary results suggest that blood loss may be diminished. |
---|