Cargando…

Hepatic Resection Using a Water Jet Dissector

The mortality and morbidity in major hepatic resection is often related to hemorrhage. A high pressure, high velocity water jet has been developed and has been utilized to assist in hepatic parenchymal transection. Sixty-seven major hepatic resections were performed for solid hepatic tumors. The tis...

Descripción completa

Detalles Bibliográficos
Autores principales: Baer, H. U., Stain, S. C., Guastella, T., Maddern, G. J., Blumgart, L. H.
Formato: Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 1993
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2443048/
https://www.ncbi.nlm.nih.gov/pubmed/8387808
http://dx.doi.org/10.1155/1993/82362
Descripción
Sumario:The mortality and morbidity in major hepatic resection is often related to hemorrhage. A high pressure, high velocity water jet has been developed and has been utilized to assist in hepatic parenchymal transection. Sixty-seven major hepatic resections were performed for solid hepatic tumors. The tissue fracture technique was used in 51 patients (76%), and the water jet dissector was used predominantly in 16 patients (24%). The extent of hepatic resection using each technique was similar. The results showed no difference in operative duration (p = .499). The mean estimated blood loss using the water jet was 1386 ml, and tissue fracture technique 2450 ml (p = .217). Transfusion requirements were less in the water jet group (mean 2.0 units) compared to the tissue fracture group (mean 5.2 units); (p = .023). Results obtained with the new water dissector are encouraging. The preliminary results suggest that blood loss may be diminished.