Cargando…
Surglcel (®) Reinforced Resection Lines in Left-sided Hepatectomy with Linear Stapling Device. An Experimental Study on Pigs
Fourteen pigs underwent left-sided hepatectomy. The resection was performed with a linear stapling device and the pigs were randomised to either Surgicel (®) reinforced resection lines or not. The median time required for resection was 25 min (range 17-30) in the Surgicel(®) reinforced group compare...
Autores principales: | , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
1996
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2443068/ https://www.ncbi.nlm.nih.gov/pubmed/8871250 http://dx.doi.org/10.1155/1996/86936 |
_version_ | 1782156781631307776 |
---|---|
author | Zilling, Thomas Holmin, Torsten |
author_facet | Zilling, Thomas Holmin, Torsten |
author_sort | Zilling, Thomas |
collection | PubMed |
description | Fourteen pigs underwent left-sided hepatectomy. The resection was performed with a linear stapling device and the pigs were randomised to either Surgicel (®) reinforced resection lines or not. The median time required for resection was 25 min (range 17-30) in the Surgicel(®) reinforced group compared to 30 min (range 21-41) in the stapled group. This difference was, however, not statistically significant (p=0.053). The postoperative haemoglobin value was lower in the stapled group compared to the Surgicel(®) reinforced group 69 g/1 (range 42-85) versus 82 g/1 (range 78-90) (p=0.018). The estimated blood losses by weighing the compresses were 287 ml (range 166-379) for the stapled group and 204 ml (range 152-264) for the Surgicel(®) reinforced group (p=0.053). The median number of additional haemostatic sutures in the Surgicel(®) reinforced group was 7 (range 3-11) and in the stapled group 10 (range 5-15) (p=0.038). The haemoglobin value was similar in the two groups week postoperatively; 100 g/1 (range 87-104) and 102 g/1 (range 95-114), p=0.27, in the stapled group and the Surgicel(®) reinforced group, respectively. In the stapled group reinforced with the Surgicel(®) there was one postoperative death. In the solely stapled group there was no postoperative death (p=0.5). Four out of six pigs in the Surgicel(®) group had massive adhesions to the resection lines. One of these six pigs was sacrificed postoperatively as it was ill and had small bowel obstruction secondary to Surgicel(®) induced adhesions. On the other hand, no adhesions were seen in the solely stapled pigs (p=0.09). At this point, we can not recommend the use of Surgicel(®) to reinforce resection lines at stapled liver resection in the clinical situation, because of the high frequency of adhesions this material creates. |
format | Text |
id | pubmed-2443068 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 1996 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-24430682008-07-08 Surglcel (®) Reinforced Resection Lines in Left-sided Hepatectomy with Linear Stapling Device. An Experimental Study on Pigs Zilling, Thomas Holmin, Torsten HPB Surg Research Article Fourteen pigs underwent left-sided hepatectomy. The resection was performed with a linear stapling device and the pigs were randomised to either Surgicel (®) reinforced resection lines or not. The median time required for resection was 25 min (range 17-30) in the Surgicel(®) reinforced group compared to 30 min (range 21-41) in the stapled group. This difference was, however, not statistically significant (p=0.053). The postoperative haemoglobin value was lower in the stapled group compared to the Surgicel(®) reinforced group 69 g/1 (range 42-85) versus 82 g/1 (range 78-90) (p=0.018). The estimated blood losses by weighing the compresses were 287 ml (range 166-379) for the stapled group and 204 ml (range 152-264) for the Surgicel(®) reinforced group (p=0.053). The median number of additional haemostatic sutures in the Surgicel(®) reinforced group was 7 (range 3-11) and in the stapled group 10 (range 5-15) (p=0.038). The haemoglobin value was similar in the two groups week postoperatively; 100 g/1 (range 87-104) and 102 g/1 (range 95-114), p=0.27, in the stapled group and the Surgicel(®) reinforced group, respectively. In the stapled group reinforced with the Surgicel(®) there was one postoperative death. In the solely stapled group there was no postoperative death (p=0.5). Four out of six pigs in the Surgicel(®) group had massive adhesions to the resection lines. One of these six pigs was sacrificed postoperatively as it was ill and had small bowel obstruction secondary to Surgicel(®) induced adhesions. On the other hand, no adhesions were seen in the solely stapled pigs (p=0.09). At this point, we can not recommend the use of Surgicel(®) to reinforce resection lines at stapled liver resection in the clinical situation, because of the high frequency of adhesions this material creates. Hindawi Publishing Corporation 1996 /pmc/articles/PMC2443068/ /pubmed/8871250 http://dx.doi.org/10.1155/1996/86936 Text en Copyright © 1996 Hindawi Publishing Corporation. http://creativecommons.org/licenses/by/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Zilling, Thomas Holmin, Torsten Surglcel (®) Reinforced Resection Lines in Left-sided Hepatectomy with Linear Stapling Device. An Experimental Study on Pigs |
title | Surglcel (®) Reinforced Resection Lines in Left-sided Hepatectomy with Linear Stapling Device. An Experimental Study on Pigs |
title_full | Surglcel (®) Reinforced Resection Lines in Left-sided Hepatectomy with Linear Stapling Device. An Experimental Study on Pigs |
title_fullStr | Surglcel (®) Reinforced Resection Lines in Left-sided Hepatectomy with Linear Stapling Device. An Experimental Study on Pigs |
title_full_unstemmed | Surglcel (®) Reinforced Resection Lines in Left-sided Hepatectomy with Linear Stapling Device. An Experimental Study on Pigs |
title_short | Surglcel (®) Reinforced Resection Lines in Left-sided Hepatectomy with Linear Stapling Device. An Experimental Study on Pigs |
title_sort | surglcel (®) reinforced resection lines in left-sided hepatectomy with linear stapling device. an experimental study on pigs |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2443068/ https://www.ncbi.nlm.nih.gov/pubmed/8871250 http://dx.doi.org/10.1155/1996/86936 |
work_keys_str_mv | AT zillingthomas surglcelreinforcedresectionlinesinleftsidedhepatectomywithlinearstaplingdeviceanexperimentalstudyonpigs AT holmintorsten surglcelreinforcedresectionlinesinleftsidedhepatectomywithlinearstaplingdeviceanexperimentalstudyonpigs |