Cargando…

Immediate and six months clinical and angiographic results of intracoronary paclitaxel-coated stent implantation – the Meo:DrugStar-1 study

The study was conducted to evaluate the clinical and angiographic results of the implantation of the paclitaxel-eluting stent Meo:DrugStar ST in patients with symptomatic coronary artery disease. The Meo:DrugStar ST stent has a stainless steel stent platform with a homogenous non-biodegradable coati...

Descripción completa

Detalles Bibliográficos
Autores principales: Uyan, Cihangir, Arinc, Huseyin, Gunduz, Huseyin, Akdemir, Ramazan
Formato: Texto
Lenguaje:English
Publicado: Dove Medical Press 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2464758/
https://www.ncbi.nlm.nih.gov/pubmed/18629363
_version_ 1782157440090898432
author Uyan, Cihangir
Arinc, Huseyin
Gunduz, Huseyin
Akdemir, Ramazan
author_facet Uyan, Cihangir
Arinc, Huseyin
Gunduz, Huseyin
Akdemir, Ramazan
author_sort Uyan, Cihangir
collection PubMed
description The study was conducted to evaluate the clinical and angiographic results of the implantation of the paclitaxel-eluting stent Meo:DrugStar ST in patients with symptomatic coronary artery disease. The Meo:DrugStar ST stent has a stainless steel stent platform with a homogenous non-biodegradable coating of paclitaxel mixed with a polyether-based biostable, monophase, and hemocompatible coating. Sixty patients with native coronary artery disease were included in the study. The Meo:DrugStar ST stents were implanted in 60 de novo lesions detected in these patients. Immediate and long-term clinical and angiographic follow-up results were evaluated. There was a high proportion of patients with hypertension (55%) according to JNC-VII. Mean stenosis ratio was 78 ± 13 %, mean implanted stent diameter was 3.0 ± 0.4 mm and mean length was 22 ± 5 mm. Restenosis was detected in 4 (10%) of those patients and 11 (27.5%) of 40 patients had insignificant amount of restenosis. The results of this study indicate a potential benefit of the Meo:DrugStar ST stent for the prevention of stent thrombosis and restenosis in these relatively high-risk patients.
format Text
id pubmed-2464758
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-24647582008-07-15 Immediate and six months clinical and angiographic results of intracoronary paclitaxel-coated stent implantation – the Meo:DrugStar-1 study Uyan, Cihangir Arinc, Huseyin Gunduz, Huseyin Akdemir, Ramazan Vasc Health Risk Manag Original Research The study was conducted to evaluate the clinical and angiographic results of the implantation of the paclitaxel-eluting stent Meo:DrugStar ST in patients with symptomatic coronary artery disease. The Meo:DrugStar ST stent has a stainless steel stent platform with a homogenous non-biodegradable coating of paclitaxel mixed with a polyether-based biostable, monophase, and hemocompatible coating. Sixty patients with native coronary artery disease were included in the study. The Meo:DrugStar ST stents were implanted in 60 de novo lesions detected in these patients. Immediate and long-term clinical and angiographic follow-up results were evaluated. There was a high proportion of patients with hypertension (55%) according to JNC-VII. Mean stenosis ratio was 78 ± 13 %, mean implanted stent diameter was 3.0 ± 0.4 mm and mean length was 22 ± 5 mm. Restenosis was detected in 4 (10%) of those patients and 11 (27.5%) of 40 patients had insignificant amount of restenosis. The results of this study indicate a potential benefit of the Meo:DrugStar ST stent for the prevention of stent thrombosis and restenosis in these relatively high-risk patients. Dove Medical Press 2008-02 /pmc/articles/PMC2464758/ /pubmed/18629363 Text en © 2008 Uyan et al, publisher and licensee Dove Medical Press Ltd.
spellingShingle Original Research
Uyan, Cihangir
Arinc, Huseyin
Gunduz, Huseyin
Akdemir, Ramazan
Immediate and six months clinical and angiographic results of intracoronary paclitaxel-coated stent implantation – the Meo:DrugStar-1 study
title Immediate and six months clinical and angiographic results of intracoronary paclitaxel-coated stent implantation – the Meo:DrugStar-1 study
title_full Immediate and six months clinical and angiographic results of intracoronary paclitaxel-coated stent implantation – the Meo:DrugStar-1 study
title_fullStr Immediate and six months clinical and angiographic results of intracoronary paclitaxel-coated stent implantation – the Meo:DrugStar-1 study
title_full_unstemmed Immediate and six months clinical and angiographic results of intracoronary paclitaxel-coated stent implantation – the Meo:DrugStar-1 study
title_short Immediate and six months clinical and angiographic results of intracoronary paclitaxel-coated stent implantation – the Meo:DrugStar-1 study
title_sort immediate and six months clinical and angiographic results of intracoronary paclitaxel-coated stent implantation – the meo:drugstar-1 study
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2464758/
https://www.ncbi.nlm.nih.gov/pubmed/18629363
work_keys_str_mv AT uyancihangir immediateandsixmonthsclinicalandangiographicresultsofintracoronarypaclitaxelcoatedstentimplantationthemeodrugstar1study
AT arinchuseyin immediateandsixmonthsclinicalandangiographicresultsofintracoronarypaclitaxelcoatedstentimplantationthemeodrugstar1study
AT gunduzhuseyin immediateandsixmonthsclinicalandangiographicresultsofintracoronarypaclitaxelcoatedstentimplantationthemeodrugstar1study
AT akdemirramazan immediateandsixmonthsclinicalandangiographicresultsofintracoronarypaclitaxelcoatedstentimplantationthemeodrugstar1study