Cargando…
Fluorescence resonance energy transfer sensors for quantitative monitoring of pentose and disaccharide accumulation in bacteria
BACKGROUND: Engineering microorganisms to improve metabolite flux requires detailed knowledge of the concentrations and flux rates of metabolites and metabolic intermediates in vivo. Fluorescence resonance energy transfer sensors represent a promising technology for measuring metabolite levels and c...
Autores principales: | , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2467413/ https://www.ncbi.nlm.nih.gov/pubmed/18522753 http://dx.doi.org/10.1186/1754-6834-1-11 |
_version_ | 1782157452101287936 |
---|---|
author | Kaper, Thijs Lager, Ida Looger, Loren L Chermak, Diane Frommer, Wolf B |
author_facet | Kaper, Thijs Lager, Ida Looger, Loren L Chermak, Diane Frommer, Wolf B |
author_sort | Kaper, Thijs |
collection | PubMed |
description | BACKGROUND: Engineering microorganisms to improve metabolite flux requires detailed knowledge of the concentrations and flux rates of metabolites and metabolic intermediates in vivo. Fluorescence resonance energy transfer sensors represent a promising technology for measuring metabolite levels and corresponding rate changes in live cells. These sensors have been applied successfully in mammalian and plant cells but potentially could also be used to monitor steady-state levels of metabolites in microorganisms using fluorimetric assays. Sensors for hexose and pentose carbohydrates could help in the development of fermentative microorganisms, for example, for biofuels applications. Arabinose is one of the carbohydrates to be monitored during biofuels production from lignocellulose, while maltose is an important degradation product of starch that is relevant for starch-derived biofuels production. RESULTS: An Escherichia coli expression vector compatible with phage λ recombination technology was constructed to facilitate sensor construction and was used to generate a novel fluorescence resonance energy transfer sensor for arabinose. In parallel, a strategy for improving the sensor signal was applied to construct an improved maltose sensor. Both sensors were expressed in the cytosol of E. coli and sugar accumulation was monitored using a simple fluorimetric assay of E. coli cultures in microtiter plates. In the case of both nanosensors, the addition of the respective ligand led to concentration-dependent fluorescence resonance energy transfer responses allowing quantitative analysis of the intracellular sugar levels at given extracellular supply levels as well as accumulation rates. CONCLUSION: The nanosensor destination vector combined with the optimization strategy for sensor responses should help to accelerate the development of metabolite sensors. The new carbohydrate fluorescence resonance energy transfer sensors can be used for in vivo monitoring of sugar levels in prokaryotes, demonstrating the potential of such sensors as reporter tools in the development of metabolically engineered microbial strains or for real-time monitoring of intracellular metabolite during fermentation. |
format | Text |
id | pubmed-2467413 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2008 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-24674132008-07-16 Fluorescence resonance energy transfer sensors for quantitative monitoring of pentose and disaccharide accumulation in bacteria Kaper, Thijs Lager, Ida Looger, Loren L Chermak, Diane Frommer, Wolf B Biotechnol Biofuels Methodology BACKGROUND: Engineering microorganisms to improve metabolite flux requires detailed knowledge of the concentrations and flux rates of metabolites and metabolic intermediates in vivo. Fluorescence resonance energy transfer sensors represent a promising technology for measuring metabolite levels and corresponding rate changes in live cells. These sensors have been applied successfully in mammalian and plant cells but potentially could also be used to monitor steady-state levels of metabolites in microorganisms using fluorimetric assays. Sensors for hexose and pentose carbohydrates could help in the development of fermentative microorganisms, for example, for biofuels applications. Arabinose is one of the carbohydrates to be monitored during biofuels production from lignocellulose, while maltose is an important degradation product of starch that is relevant for starch-derived biofuels production. RESULTS: An Escherichia coli expression vector compatible with phage λ recombination technology was constructed to facilitate sensor construction and was used to generate a novel fluorescence resonance energy transfer sensor for arabinose. In parallel, a strategy for improving the sensor signal was applied to construct an improved maltose sensor. Both sensors were expressed in the cytosol of E. coli and sugar accumulation was monitored using a simple fluorimetric assay of E. coli cultures in microtiter plates. In the case of both nanosensors, the addition of the respective ligand led to concentration-dependent fluorescence resonance energy transfer responses allowing quantitative analysis of the intracellular sugar levels at given extracellular supply levels as well as accumulation rates. CONCLUSION: The nanosensor destination vector combined with the optimization strategy for sensor responses should help to accelerate the development of metabolite sensors. The new carbohydrate fluorescence resonance energy transfer sensors can be used for in vivo monitoring of sugar levels in prokaryotes, demonstrating the potential of such sensors as reporter tools in the development of metabolically engineered microbial strains or for real-time monitoring of intracellular metabolite during fermentation. BioMed Central 2008-06-03 /pmc/articles/PMC2467413/ /pubmed/18522753 http://dx.doi.org/10.1186/1754-6834-1-11 Text en Copyright © 2008 Kaper et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Methodology Kaper, Thijs Lager, Ida Looger, Loren L Chermak, Diane Frommer, Wolf B Fluorescence resonance energy transfer sensors for quantitative monitoring of pentose and disaccharide accumulation in bacteria |
title | Fluorescence resonance energy transfer sensors for quantitative monitoring of pentose and disaccharide accumulation in bacteria |
title_full | Fluorescence resonance energy transfer sensors for quantitative monitoring of pentose and disaccharide accumulation in bacteria |
title_fullStr | Fluorescence resonance energy transfer sensors for quantitative monitoring of pentose and disaccharide accumulation in bacteria |
title_full_unstemmed | Fluorescence resonance energy transfer sensors for quantitative monitoring of pentose and disaccharide accumulation in bacteria |
title_short | Fluorescence resonance energy transfer sensors for quantitative monitoring of pentose and disaccharide accumulation in bacteria |
title_sort | fluorescence resonance energy transfer sensors for quantitative monitoring of pentose and disaccharide accumulation in bacteria |
topic | Methodology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2467413/ https://www.ncbi.nlm.nih.gov/pubmed/18522753 http://dx.doi.org/10.1186/1754-6834-1-11 |
work_keys_str_mv | AT kaperthijs fluorescenceresonanceenergytransfersensorsforquantitativemonitoringofpentoseanddisaccharideaccumulationinbacteria AT lagerida fluorescenceresonanceenergytransfersensorsforquantitativemonitoringofpentoseanddisaccharideaccumulationinbacteria AT loogerlorenl fluorescenceresonanceenergytransfersensorsforquantitativemonitoringofpentoseanddisaccharideaccumulationinbacteria AT chermakdiane fluorescenceresonanceenergytransfersensorsforquantitativemonitoringofpentoseanddisaccharideaccumulationinbacteria AT frommerwolfb fluorescenceresonanceenergytransfersensorsforquantitativemonitoringofpentoseanddisaccharideaccumulationinbacteria |