Cargando…

Mineral oil certified reference materials for the determination of polychlorinated biphenyls from the National Metrology Institute of Japan (NMIJ)

Four mineral oil certified reference materials (CRMs), NMIJ CRM 7902-a, CRM 7903-a, CRM 7904-a, and CRM 7905-a, have been issued by the National Metrology Institute of Japan, which is part of the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST), for the determination of p...

Descripción completa

Detalles Bibliográficos
Autores principales: Numata, Masahiko, Aoyagi, Yoshie, Matsuo, Mayumi, Ishikawa, Keiichiro, Hanari, Nobuyasu, Otsuka, Satoko, Tsuda, Yoko, Yarita, Takashi
Formato: Texto
Lenguaje:English
Publicado: Springer-Verlag 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2467535/
https://www.ncbi.nlm.nih.gov/pubmed/18415091
http://dx.doi.org/10.1007/s00216-008-2010-3
_version_ 1782157470848778240
author Numata, Masahiko
Aoyagi, Yoshie
Matsuo, Mayumi
Ishikawa, Keiichiro
Hanari, Nobuyasu
Otsuka, Satoko
Tsuda, Yoko
Yarita, Takashi
author_facet Numata, Masahiko
Aoyagi, Yoshie
Matsuo, Mayumi
Ishikawa, Keiichiro
Hanari, Nobuyasu
Otsuka, Satoko
Tsuda, Yoko
Yarita, Takashi
author_sort Numata, Masahiko
collection PubMed
description Four mineral oil certified reference materials (CRMs), NMIJ CRM 7902-a, CRM 7903-a, CRM 7904-a, and CRM 7905-a, have been issued by the National Metrology Institute of Japan, which is part of the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST), for the determination of polychlorinated biphenyls (PCBs). The raw materials for the CRMs were an insulation oil (CRM 7902-a and CRM 7903-a) and a fuel oil (CRM7904-a and CRM 7905-a). A solution of PCB3, PCB8, and technical PCB products, comprising four types of Kaneclor, was added to the oil matrices. The total PCB concentrations in the PCB-fortified oils (CRM 7902-a and CRM 7904-a) are approximately 6 mg kg(−1). In addition, the mineral oils which were not fortified with PCBs were also distributed as CRMs (CRM 7903-a and CRM 7905-a). Characterization of these CRMs was conducted by the NMIJ/AIST, where the mineral oils and the PCB solution were analyzed using multiple analytical methods such as dimethylsulfoxide extraction, normal-phase liquid chromatography, gel permeation chromatography, reversed-phase liquid chromatography, and chromatography using sulfoxide-bonded silica; and/or various capillary columns for gas chromatography, and two ionization modes for mass spectrometry. The target compounds in the mineral oils and those in the PCB solution were determined by one of the primary methods of measurement, isotope dilution–mass spectrometry (ID-MS). Certified values have been provided for 11 PCB congeners (PCB3, 8, 28, 52, 101, 118, 138, 153, 180, 194, and 206) in the CRMs. These CRMs have information values for PCB homologue concentrations determined by using a Japanese official method for determination of PCBs in wastes and densities determined with an oscillational density meter. Because oil samples having arbitrary PCB concentrations between respective property values of the PCB-fortified and nonfortified CRMs can be prepared by gravimetric mixing of the CRM pairs, these CRMs can be used for validation of PCB analyses using various instruments which have different sensitivities. [Figure: see text] ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s00216-008-2010-3) contains supplementary material, which is available to authorized users.
format Text
id pubmed-2467535
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher Springer-Verlag
record_format MEDLINE/PubMed
spelling pubmed-24675352008-07-16 Mineral oil certified reference materials for the determination of polychlorinated biphenyls from the National Metrology Institute of Japan (NMIJ) Numata, Masahiko Aoyagi, Yoshie Matsuo, Mayumi Ishikawa, Keiichiro Hanari, Nobuyasu Otsuka, Satoko Tsuda, Yoko Yarita, Takashi Anal Bioanal Chem Original Paper Four mineral oil certified reference materials (CRMs), NMIJ CRM 7902-a, CRM 7903-a, CRM 7904-a, and CRM 7905-a, have been issued by the National Metrology Institute of Japan, which is part of the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST), for the determination of polychlorinated biphenyls (PCBs). The raw materials for the CRMs were an insulation oil (CRM 7902-a and CRM 7903-a) and a fuel oil (CRM7904-a and CRM 7905-a). A solution of PCB3, PCB8, and technical PCB products, comprising four types of Kaneclor, was added to the oil matrices. The total PCB concentrations in the PCB-fortified oils (CRM 7902-a and CRM 7904-a) are approximately 6 mg kg(−1). In addition, the mineral oils which were not fortified with PCBs were also distributed as CRMs (CRM 7903-a and CRM 7905-a). Characterization of these CRMs was conducted by the NMIJ/AIST, where the mineral oils and the PCB solution were analyzed using multiple analytical methods such as dimethylsulfoxide extraction, normal-phase liquid chromatography, gel permeation chromatography, reversed-phase liquid chromatography, and chromatography using sulfoxide-bonded silica; and/or various capillary columns for gas chromatography, and two ionization modes for mass spectrometry. The target compounds in the mineral oils and those in the PCB solution were determined by one of the primary methods of measurement, isotope dilution–mass spectrometry (ID-MS). Certified values have been provided for 11 PCB congeners (PCB3, 8, 28, 52, 101, 118, 138, 153, 180, 194, and 206) in the CRMs. These CRMs have information values for PCB homologue concentrations determined by using a Japanese official method for determination of PCBs in wastes and densities determined with an oscillational density meter. Because oil samples having arbitrary PCB concentrations between respective property values of the PCB-fortified and nonfortified CRMs can be prepared by gravimetric mixing of the CRM pairs, these CRMs can be used for validation of PCB analyses using various instruments which have different sensitivities. [Figure: see text] ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s00216-008-2010-3) contains supplementary material, which is available to authorized users. Springer-Verlag 2008-04-16 2008-07 /pmc/articles/PMC2467535/ /pubmed/18415091 http://dx.doi.org/10.1007/s00216-008-2010-3 Text en © Springer-Verlag 2008
spellingShingle Original Paper
Numata, Masahiko
Aoyagi, Yoshie
Matsuo, Mayumi
Ishikawa, Keiichiro
Hanari, Nobuyasu
Otsuka, Satoko
Tsuda, Yoko
Yarita, Takashi
Mineral oil certified reference materials for the determination of polychlorinated biphenyls from the National Metrology Institute of Japan (NMIJ)
title Mineral oil certified reference materials for the determination of polychlorinated biphenyls from the National Metrology Institute of Japan (NMIJ)
title_full Mineral oil certified reference materials for the determination of polychlorinated biphenyls from the National Metrology Institute of Japan (NMIJ)
title_fullStr Mineral oil certified reference materials for the determination of polychlorinated biphenyls from the National Metrology Institute of Japan (NMIJ)
title_full_unstemmed Mineral oil certified reference materials for the determination of polychlorinated biphenyls from the National Metrology Institute of Japan (NMIJ)
title_short Mineral oil certified reference materials for the determination of polychlorinated biphenyls from the National Metrology Institute of Japan (NMIJ)
title_sort mineral oil certified reference materials for the determination of polychlorinated biphenyls from the national metrology institute of japan (nmij)
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2467535/
https://www.ncbi.nlm.nih.gov/pubmed/18415091
http://dx.doi.org/10.1007/s00216-008-2010-3
work_keys_str_mv AT numatamasahiko mineraloilcertifiedreferencematerialsforthedeterminationofpolychlorinatedbiphenylsfromthenationalmetrologyinstituteofjapannmij
AT aoyagiyoshie mineraloilcertifiedreferencematerialsforthedeterminationofpolychlorinatedbiphenylsfromthenationalmetrologyinstituteofjapannmij
AT matsuomayumi mineraloilcertifiedreferencematerialsforthedeterminationofpolychlorinatedbiphenylsfromthenationalmetrologyinstituteofjapannmij
AT ishikawakeiichiro mineraloilcertifiedreferencematerialsforthedeterminationofpolychlorinatedbiphenylsfromthenationalmetrologyinstituteofjapannmij
AT hanarinobuyasu mineraloilcertifiedreferencematerialsforthedeterminationofpolychlorinatedbiphenylsfromthenationalmetrologyinstituteofjapannmij
AT otsukasatoko mineraloilcertifiedreferencematerialsforthedeterminationofpolychlorinatedbiphenylsfromthenationalmetrologyinstituteofjapannmij
AT tsudayoko mineraloilcertifiedreferencematerialsforthedeterminationofpolychlorinatedbiphenylsfromthenationalmetrologyinstituteofjapannmij
AT yaritatakashi mineraloilcertifiedreferencematerialsforthedeterminationofpolychlorinatedbiphenylsfromthenationalmetrologyinstituteofjapannmij