Cargando…
Mineral oil certified reference materials for the determination of polychlorinated biphenyls from the National Metrology Institute of Japan (NMIJ)
Four mineral oil certified reference materials (CRMs), NMIJ CRM 7902-a, CRM 7903-a, CRM 7904-a, and CRM 7905-a, have been issued by the National Metrology Institute of Japan, which is part of the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST), for the determination of p...
Autores principales: | , , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Springer-Verlag
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2467535/ https://www.ncbi.nlm.nih.gov/pubmed/18415091 http://dx.doi.org/10.1007/s00216-008-2010-3 |
_version_ | 1782157470848778240 |
---|---|
author | Numata, Masahiko Aoyagi, Yoshie Matsuo, Mayumi Ishikawa, Keiichiro Hanari, Nobuyasu Otsuka, Satoko Tsuda, Yoko Yarita, Takashi |
author_facet | Numata, Masahiko Aoyagi, Yoshie Matsuo, Mayumi Ishikawa, Keiichiro Hanari, Nobuyasu Otsuka, Satoko Tsuda, Yoko Yarita, Takashi |
author_sort | Numata, Masahiko |
collection | PubMed |
description | Four mineral oil certified reference materials (CRMs), NMIJ CRM 7902-a, CRM 7903-a, CRM 7904-a, and CRM 7905-a, have been issued by the National Metrology Institute of Japan, which is part of the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST), for the determination of polychlorinated biphenyls (PCBs). The raw materials for the CRMs were an insulation oil (CRM 7902-a and CRM 7903-a) and a fuel oil (CRM7904-a and CRM 7905-a). A solution of PCB3, PCB8, and technical PCB products, comprising four types of Kaneclor, was added to the oil matrices. The total PCB concentrations in the PCB-fortified oils (CRM 7902-a and CRM 7904-a) are approximately 6 mg kg(−1). In addition, the mineral oils which were not fortified with PCBs were also distributed as CRMs (CRM 7903-a and CRM 7905-a). Characterization of these CRMs was conducted by the NMIJ/AIST, where the mineral oils and the PCB solution were analyzed using multiple analytical methods such as dimethylsulfoxide extraction, normal-phase liquid chromatography, gel permeation chromatography, reversed-phase liquid chromatography, and chromatography using sulfoxide-bonded silica; and/or various capillary columns for gas chromatography, and two ionization modes for mass spectrometry. The target compounds in the mineral oils and those in the PCB solution were determined by one of the primary methods of measurement, isotope dilution–mass spectrometry (ID-MS). Certified values have been provided for 11 PCB congeners (PCB3, 8, 28, 52, 101, 118, 138, 153, 180, 194, and 206) in the CRMs. These CRMs have information values for PCB homologue concentrations determined by using a Japanese official method for determination of PCBs in wastes and densities determined with an oscillational density meter. Because oil samples having arbitrary PCB concentrations between respective property values of the PCB-fortified and nonfortified CRMs can be prepared by gravimetric mixing of the CRM pairs, these CRMs can be used for validation of PCB analyses using various instruments which have different sensitivities. [Figure: see text] ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s00216-008-2010-3) contains supplementary material, which is available to authorized users. |
format | Text |
id | pubmed-2467535 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2008 |
publisher | Springer-Verlag |
record_format | MEDLINE/PubMed |
spelling | pubmed-24675352008-07-16 Mineral oil certified reference materials for the determination of polychlorinated biphenyls from the National Metrology Institute of Japan (NMIJ) Numata, Masahiko Aoyagi, Yoshie Matsuo, Mayumi Ishikawa, Keiichiro Hanari, Nobuyasu Otsuka, Satoko Tsuda, Yoko Yarita, Takashi Anal Bioanal Chem Original Paper Four mineral oil certified reference materials (CRMs), NMIJ CRM 7902-a, CRM 7903-a, CRM 7904-a, and CRM 7905-a, have been issued by the National Metrology Institute of Japan, which is part of the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST), for the determination of polychlorinated biphenyls (PCBs). The raw materials for the CRMs were an insulation oil (CRM 7902-a and CRM 7903-a) and a fuel oil (CRM7904-a and CRM 7905-a). A solution of PCB3, PCB8, and technical PCB products, comprising four types of Kaneclor, was added to the oil matrices. The total PCB concentrations in the PCB-fortified oils (CRM 7902-a and CRM 7904-a) are approximately 6 mg kg(−1). In addition, the mineral oils which were not fortified with PCBs were also distributed as CRMs (CRM 7903-a and CRM 7905-a). Characterization of these CRMs was conducted by the NMIJ/AIST, where the mineral oils and the PCB solution were analyzed using multiple analytical methods such as dimethylsulfoxide extraction, normal-phase liquid chromatography, gel permeation chromatography, reversed-phase liquid chromatography, and chromatography using sulfoxide-bonded silica; and/or various capillary columns for gas chromatography, and two ionization modes for mass spectrometry. The target compounds in the mineral oils and those in the PCB solution were determined by one of the primary methods of measurement, isotope dilution–mass spectrometry (ID-MS). Certified values have been provided for 11 PCB congeners (PCB3, 8, 28, 52, 101, 118, 138, 153, 180, 194, and 206) in the CRMs. These CRMs have information values for PCB homologue concentrations determined by using a Japanese official method for determination of PCBs in wastes and densities determined with an oscillational density meter. Because oil samples having arbitrary PCB concentrations between respective property values of the PCB-fortified and nonfortified CRMs can be prepared by gravimetric mixing of the CRM pairs, these CRMs can be used for validation of PCB analyses using various instruments which have different sensitivities. [Figure: see text] ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s00216-008-2010-3) contains supplementary material, which is available to authorized users. Springer-Verlag 2008-04-16 2008-07 /pmc/articles/PMC2467535/ /pubmed/18415091 http://dx.doi.org/10.1007/s00216-008-2010-3 Text en © Springer-Verlag 2008 |
spellingShingle | Original Paper Numata, Masahiko Aoyagi, Yoshie Matsuo, Mayumi Ishikawa, Keiichiro Hanari, Nobuyasu Otsuka, Satoko Tsuda, Yoko Yarita, Takashi Mineral oil certified reference materials for the determination of polychlorinated biphenyls from the National Metrology Institute of Japan (NMIJ) |
title | Mineral oil certified reference materials for the determination of polychlorinated biphenyls from the National Metrology Institute of Japan (NMIJ) |
title_full | Mineral oil certified reference materials for the determination of polychlorinated biphenyls from the National Metrology Institute of Japan (NMIJ) |
title_fullStr | Mineral oil certified reference materials for the determination of polychlorinated biphenyls from the National Metrology Institute of Japan (NMIJ) |
title_full_unstemmed | Mineral oil certified reference materials for the determination of polychlorinated biphenyls from the National Metrology Institute of Japan (NMIJ) |
title_short | Mineral oil certified reference materials for the determination of polychlorinated biphenyls from the National Metrology Institute of Japan (NMIJ) |
title_sort | mineral oil certified reference materials for the determination of polychlorinated biphenyls from the national metrology institute of japan (nmij) |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2467535/ https://www.ncbi.nlm.nih.gov/pubmed/18415091 http://dx.doi.org/10.1007/s00216-008-2010-3 |
work_keys_str_mv | AT numatamasahiko mineraloilcertifiedreferencematerialsforthedeterminationofpolychlorinatedbiphenylsfromthenationalmetrologyinstituteofjapannmij AT aoyagiyoshie mineraloilcertifiedreferencematerialsforthedeterminationofpolychlorinatedbiphenylsfromthenationalmetrologyinstituteofjapannmij AT matsuomayumi mineraloilcertifiedreferencematerialsforthedeterminationofpolychlorinatedbiphenylsfromthenationalmetrologyinstituteofjapannmij AT ishikawakeiichiro mineraloilcertifiedreferencematerialsforthedeterminationofpolychlorinatedbiphenylsfromthenationalmetrologyinstituteofjapannmij AT hanarinobuyasu mineraloilcertifiedreferencematerialsforthedeterminationofpolychlorinatedbiphenylsfromthenationalmetrologyinstituteofjapannmij AT otsukasatoko mineraloilcertifiedreferencematerialsforthedeterminationofpolychlorinatedbiphenylsfromthenationalmetrologyinstituteofjapannmij AT tsudayoko mineraloilcertifiedreferencematerialsforthedeterminationofpolychlorinatedbiphenylsfromthenationalmetrologyinstituteofjapannmij AT yaritatakashi mineraloilcertifiedreferencematerialsforthedeterminationofpolychlorinatedbiphenylsfromthenationalmetrologyinstituteofjapannmij |