Use of virtual slide system for quick frozen intra-operative telepathology diagnosis in Kyoto, Japan

We started to use virtual slide (VS) and virtual microscopy (VM) systems for quick frozen intra-operative telepathology diagnosis in Kyoto, Japan. In the system we used a digital slide scanner, VASSALO by CLARO Inc., and a broadband optic fibre provided by NTT West Japan Inc. with the best effort ca...

Descripción completa

Detalles Bibliográficos
Autores principales: Tsuchihashi, Yasunari, Takamatsu, Terumasa, Hashimoto, Yukimasa, Takashima, Tooru, Nakano, Kooji, Fujita, Setsuya
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2500112/
https://www.ncbi.nlm.nih.gov/pubmed/18673520
http://dx.doi.org/10.1186/1746-1596-3-S1-S6
_version_ 1782158300877422592
author Tsuchihashi, Yasunari
Takamatsu, Terumasa
Hashimoto, Yukimasa
Takashima, Tooru
Nakano, Kooji
Fujita, Setsuya
author_facet Tsuchihashi, Yasunari
Takamatsu, Terumasa
Hashimoto, Yukimasa
Takashima, Tooru
Nakano, Kooji
Fujita, Setsuya
author_sort Tsuchihashi, Yasunari
collection PubMed
description We started to use virtual slide (VS) and virtual microscopy (VM) systems for quick frozen intra-operative telepathology diagnosis in Kyoto, Japan. In the system we used a digital slide scanner, VASSALO by CLARO Inc., and a broadband optic fibre provided by NTT West Japan Inc. with the best effort capacity of 100 Mbps. The client is the pathology laboratory of Yamashiro Public hospital, one of the local centre hospitals located in the south of Kyoto Prefecture, where a fulltime pathologist is not present. The client is connected by VPN to the telepathology centre of our institute located in central Kyoto. As a result of the recent 15 test cases of VS telepathology diagnosis, including cases judging negative or positive surgical margins, we could estimate the usefulness of VS in intra-operative remote diagnosis. The time required for the frozen section VS file making was found to be around 10 min when we use ×10 objective and if the maximal dimension of the frozen sample is less than 20 mm. Good correct focus of VS images was attained in all cases and all the fields of each tissue specimen. Up to now the capacity of best effort B-band appears to be sufficient to attain diagnosis on time in intra-operation. Telepathology diagnosis was achieved within 5 minutes in most cases using VS viewer provided by CLARO Inc. The VS telepathology system was found to be superior to the conventional still image telepathology system using a robotic microscope since in the former we can observe much greater image information than in the latter in a certain limited time of intra-operation and in the much more efficient ways. In the near future VS telepathology will replace conventional still image telepathology with a robotic microscope even in quick frozen intra-operative diagnosis.
format Text
id pubmed-2500112
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-25001122008-08-08 Use of virtual slide system for quick frozen intra-operative telepathology diagnosis in Kyoto, Japan Tsuchihashi, Yasunari Takamatsu, Terumasa Hashimoto, Yukimasa Takashima, Tooru Nakano, Kooji Fujita, Setsuya Diagn Pathol Proceedings We started to use virtual slide (VS) and virtual microscopy (VM) systems for quick frozen intra-operative telepathology diagnosis in Kyoto, Japan. In the system we used a digital slide scanner, VASSALO by CLARO Inc., and a broadband optic fibre provided by NTT West Japan Inc. with the best effort capacity of 100 Mbps. The client is the pathology laboratory of Yamashiro Public hospital, one of the local centre hospitals located in the south of Kyoto Prefecture, where a fulltime pathologist is not present. The client is connected by VPN to the telepathology centre of our institute located in central Kyoto. As a result of the recent 15 test cases of VS telepathology diagnosis, including cases judging negative or positive surgical margins, we could estimate the usefulness of VS in intra-operative remote diagnosis. The time required for the frozen section VS file making was found to be around 10 min when we use ×10 objective and if the maximal dimension of the frozen sample is less than 20 mm. Good correct focus of VS images was attained in all cases and all the fields of each tissue specimen. Up to now the capacity of best effort B-band appears to be sufficient to attain diagnosis on time in intra-operation. Telepathology diagnosis was achieved within 5 minutes in most cases using VS viewer provided by CLARO Inc. The VS telepathology system was found to be superior to the conventional still image telepathology system using a robotic microscope since in the former we can observe much greater image information than in the latter in a certain limited time of intra-operation and in the much more efficient ways. In the near future VS telepathology will replace conventional still image telepathology with a robotic microscope even in quick frozen intra-operative diagnosis. BioMed Central 2008-07-15 /pmc/articles/PMC2500112/ /pubmed/18673520 http://dx.doi.org/10.1186/1746-1596-3-S1-S6 Text en Copyright © 2008 Tsuchihashi et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an open access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Proceedings
Tsuchihashi, Yasunari
Takamatsu, Terumasa
Hashimoto, Yukimasa
Takashima, Tooru
Nakano, Kooji
Fujita, Setsuya
Use of virtual slide system for quick frozen intra-operative telepathology diagnosis in Kyoto, Japan
title Use of virtual slide system for quick frozen intra-operative telepathology diagnosis in Kyoto, Japan
title_full Use of virtual slide system for quick frozen intra-operative telepathology diagnosis in Kyoto, Japan
title_fullStr Use of virtual slide system for quick frozen intra-operative telepathology diagnosis in Kyoto, Japan
title_full_unstemmed Use of virtual slide system for quick frozen intra-operative telepathology diagnosis in Kyoto, Japan
title_short Use of virtual slide system for quick frozen intra-operative telepathology diagnosis in Kyoto, Japan
title_sort use of virtual slide system for quick frozen intra-operative telepathology diagnosis in kyoto, japan
topic Proceedings
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2500112/
https://www.ncbi.nlm.nih.gov/pubmed/18673520
http://dx.doi.org/10.1186/1746-1596-3-S1-S6
work_keys_str_mv AT tsuchihashiyasunari useofvirtualslidesystemforquickfrozenintraoperativetelepathologydiagnosisinkyotojapan
AT takamatsuterumasa useofvirtualslidesystemforquickfrozenintraoperativetelepathologydiagnosisinkyotojapan
AT hashimotoyukimasa useofvirtualslidesystemforquickfrozenintraoperativetelepathologydiagnosisinkyotojapan
AT takashimatooru useofvirtualslidesystemforquickfrozenintraoperativetelepathologydiagnosisinkyotojapan
AT nakanokooji useofvirtualslidesystemforquickfrozenintraoperativetelepathologydiagnosisinkyotojapan
AT fujitasetsuya useofvirtualslidesystemforquickfrozenintraoperativetelepathologydiagnosisinkyotojapan