Cargando…

Reliability of home CPAP titration with different automatic CPAP devices

BACKGROUND: CPAP titration may be completed by automatic apparatus. However, differences in pressure behaviour could interfere with the reliability of pressure recommendations. Our objective was to compare pressure behaviour and effective pressure recommendations between three Automatic CPAP machine...

Descripción completa

Detalles Bibliográficos
Autores principales: Sériès, Frédéric, Plante, Julie, Lacasse, Yves
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2515310/
https://www.ncbi.nlm.nih.gov/pubmed/18652688
http://dx.doi.org/10.1186/1465-9921-9-56
_version_ 1782158411803131904
author Sériès, Frédéric
Plante, Julie
Lacasse, Yves
author_facet Sériès, Frédéric
Plante, Julie
Lacasse, Yves
author_sort Sériès, Frédéric
collection PubMed
description BACKGROUND: CPAP titration may be completed by automatic apparatus. However, differences in pressure behaviour could interfere with the reliability of pressure recommendations. Our objective was to compare pressure behaviour and effective pressure recommendations between three Automatic CPAP machines (Autoset Spirit, Remstar Auto, GK 420). METHODS: Sixteen untreated obstructive sleep apnea patients were randomly allocated to one of the 3 tested machines for a one-week home titration trial in a crossover design with a 10 days washout period between trials. RESULTS: The median pressure value was significantly lower with machine GK 420 (5.9 +/- 1.8 cm H(2)O) than with the other devices both after one night and one week of CPAP titration (7.4 +/- 1.3 and 6.6 +/- 1.9 cm H(2)O). The maximal pressure obtained over the one-week titration was significantly higher with Remstar Auto (12.6 +/- 2.4 cm H(2)O, Mean +/- SD) than with the two other ones (10.9 +/- 1.0 and 11.0 +/- 2.4 cm H(2)O). The variance in pressure recommendation significantly differed between the three machines after one night and between Autoset Spirit and the two other machines after 1 week. CONCLUSION: Pressure behaviour and pressure recommendation significantly differ between Auto CPAP machines both after one night and one week of home titration.
format Text
id pubmed-2515310
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-25153102008-08-13 Reliability of home CPAP titration with different automatic CPAP devices Sériès, Frédéric Plante, Julie Lacasse, Yves Respir Res Research BACKGROUND: CPAP titration may be completed by automatic apparatus. However, differences in pressure behaviour could interfere with the reliability of pressure recommendations. Our objective was to compare pressure behaviour and effective pressure recommendations between three Automatic CPAP machines (Autoset Spirit, Remstar Auto, GK 420). METHODS: Sixteen untreated obstructive sleep apnea patients were randomly allocated to one of the 3 tested machines for a one-week home titration trial in a crossover design with a 10 days washout period between trials. RESULTS: The median pressure value was significantly lower with machine GK 420 (5.9 +/- 1.8 cm H(2)O) than with the other devices both after one night and one week of CPAP titration (7.4 +/- 1.3 and 6.6 +/- 1.9 cm H(2)O). The maximal pressure obtained over the one-week titration was significantly higher with Remstar Auto (12.6 +/- 2.4 cm H(2)O, Mean +/- SD) than with the two other ones (10.9 +/- 1.0 and 11.0 +/- 2.4 cm H(2)O). The variance in pressure recommendation significantly differed between the three machines after one night and between Autoset Spirit and the two other machines after 1 week. CONCLUSION: Pressure behaviour and pressure recommendation significantly differ between Auto CPAP machines both after one night and one week of home titration. BioMed Central 2008 2008-07-24 /pmc/articles/PMC2515310/ /pubmed/18652688 http://dx.doi.org/10.1186/1465-9921-9-56 Text en Copyright © 2008 Sériès et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Sériès, Frédéric
Plante, Julie
Lacasse, Yves
Reliability of home CPAP titration with different automatic CPAP devices
title Reliability of home CPAP titration with different automatic CPAP devices
title_full Reliability of home CPAP titration with different automatic CPAP devices
title_fullStr Reliability of home CPAP titration with different automatic CPAP devices
title_full_unstemmed Reliability of home CPAP titration with different automatic CPAP devices
title_short Reliability of home CPAP titration with different automatic CPAP devices
title_sort reliability of home cpap titration with different automatic cpap devices
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2515310/
https://www.ncbi.nlm.nih.gov/pubmed/18652688
http://dx.doi.org/10.1186/1465-9921-9-56
work_keys_str_mv AT seriesfrederic reliabilityofhomecpaptitrationwithdifferentautomaticcpapdevices
AT plantejulie reliabilityofhomecpaptitrationwithdifferentautomaticcpapdevices
AT lacasseyves reliabilityofhomecpaptitrationwithdifferentautomaticcpapdevices