Cargando…

Critical evaluation of HPV16 gene copy number quantification by SYBR green PCR

BACKGROUND: Human papilloma virus (HPV) load and physical status are considered useful parameters for clinical evaluation of cervical squamous cell neoplasia. However, the errors implicit in HPV gene quantification by PCR are not well documented. We have undertaken the first rigorous evaluation of t...

Descripción completa

Detalles Bibliográficos
Autores principales: Roberts, Ian, Ng, Grace, Foster, Nicola, Stanley, Margaret, Herdman, Michael T, Pett, Mark R, Teschendorff, Andrew, Coleman, Nicholas
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2529285/
https://www.ncbi.nlm.nih.gov/pubmed/18652663
http://dx.doi.org/10.1186/1472-6750-8-57
_version_ 1782158908194816000
author Roberts, Ian
Ng, Grace
Foster, Nicola
Stanley, Margaret
Herdman, Michael T
Pett, Mark R
Teschendorff, Andrew
Coleman, Nicholas
author_facet Roberts, Ian
Ng, Grace
Foster, Nicola
Stanley, Margaret
Herdman, Michael T
Pett, Mark R
Teschendorff, Andrew
Coleman, Nicholas
author_sort Roberts, Ian
collection PubMed
description BACKGROUND: Human papilloma virus (HPV) load and physical status are considered useful parameters for clinical evaluation of cervical squamous cell neoplasia. However, the errors implicit in HPV gene quantification by PCR are not well documented. We have undertaken the first rigorous evaluation of the errors that can be expected when using SYBR green qPCR for quantification of HPV type 16 gene copy numbers. We assessed a modified method, in which external calibration curves were generated from a single construct containing HPV16 E2, HPV16 E6 and the host gene hydroxymethylbilane synthase in a 1:1:1 ratio. RESULTS: When testing dilutions of mixed HPV/host DNA in replicate runs, we observed errors in quantifying E2 and E6 amplicons of 5–40%, with greatest error at the lowest DNA template concentration (3 ng/μl). Errors in determining viral copy numbers per diploid genome were 13–53%. Nevertheless, in cervical keratinocyte cell lines we observed reasonable agreement between viral loads determined by qPCR and Southern blotting. The mean E2/E6 ratio in episome-only cells was 1.04, but with a range of 0.76–1.32. In three integrant-only lines the mean E2/E6 ratios were 0.20, 0.72 and 2.61 (values confirmed by gene-specific Southern blotting). When E2/E6 ratios in fourteen HPV16-positive cervical carcinomas were analysed, conclusions regarding viral physical state could only be made in three cases, where the E2/E6 ratio was ≤ 0.06. CONCLUSION: Run-to-run variation in SYBR green qPCR produces unavoidable inaccuracies that should be allowed for when quantifying HPV gene copy number. While E6 copy numbers can be considered to provide a useable indication of viral loads, the E2/E6 ratio is of limited value. Previous studies may have overestimated the frequency of mixed episomal/integrant HPV infections.
format Text
id pubmed-2529285
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-25292852008-09-05 Critical evaluation of HPV16 gene copy number quantification by SYBR green PCR Roberts, Ian Ng, Grace Foster, Nicola Stanley, Margaret Herdman, Michael T Pett, Mark R Teschendorff, Andrew Coleman, Nicholas BMC Biotechnol Research Article BACKGROUND: Human papilloma virus (HPV) load and physical status are considered useful parameters for clinical evaluation of cervical squamous cell neoplasia. However, the errors implicit in HPV gene quantification by PCR are not well documented. We have undertaken the first rigorous evaluation of the errors that can be expected when using SYBR green qPCR for quantification of HPV type 16 gene copy numbers. We assessed a modified method, in which external calibration curves were generated from a single construct containing HPV16 E2, HPV16 E6 and the host gene hydroxymethylbilane synthase in a 1:1:1 ratio. RESULTS: When testing dilutions of mixed HPV/host DNA in replicate runs, we observed errors in quantifying E2 and E6 amplicons of 5–40%, with greatest error at the lowest DNA template concentration (3 ng/μl). Errors in determining viral copy numbers per diploid genome were 13–53%. Nevertheless, in cervical keratinocyte cell lines we observed reasonable agreement between viral loads determined by qPCR and Southern blotting. The mean E2/E6 ratio in episome-only cells was 1.04, but with a range of 0.76–1.32. In three integrant-only lines the mean E2/E6 ratios were 0.20, 0.72 and 2.61 (values confirmed by gene-specific Southern blotting). When E2/E6 ratios in fourteen HPV16-positive cervical carcinomas were analysed, conclusions regarding viral physical state could only be made in three cases, where the E2/E6 ratio was ≤ 0.06. CONCLUSION: Run-to-run variation in SYBR green qPCR produces unavoidable inaccuracies that should be allowed for when quantifying HPV gene copy number. While E6 copy numbers can be considered to provide a useable indication of viral loads, the E2/E6 ratio is of limited value. Previous studies may have overestimated the frequency of mixed episomal/integrant HPV infections. BioMed Central 2008-07-24 /pmc/articles/PMC2529285/ /pubmed/18652663 http://dx.doi.org/10.1186/1472-6750-8-57 Text en Copyright © 2008 Roberts et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Roberts, Ian
Ng, Grace
Foster, Nicola
Stanley, Margaret
Herdman, Michael T
Pett, Mark R
Teschendorff, Andrew
Coleman, Nicholas
Critical evaluation of HPV16 gene copy number quantification by SYBR green PCR
title Critical evaluation of HPV16 gene copy number quantification by SYBR green PCR
title_full Critical evaluation of HPV16 gene copy number quantification by SYBR green PCR
title_fullStr Critical evaluation of HPV16 gene copy number quantification by SYBR green PCR
title_full_unstemmed Critical evaluation of HPV16 gene copy number quantification by SYBR green PCR
title_short Critical evaluation of HPV16 gene copy number quantification by SYBR green PCR
title_sort critical evaluation of hpv16 gene copy number quantification by sybr green pcr
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2529285/
https://www.ncbi.nlm.nih.gov/pubmed/18652663
http://dx.doi.org/10.1186/1472-6750-8-57
work_keys_str_mv AT robertsian criticalevaluationofhpv16genecopynumberquantificationbysybrgreenpcr
AT nggrace criticalevaluationofhpv16genecopynumberquantificationbysybrgreenpcr
AT fosternicola criticalevaluationofhpv16genecopynumberquantificationbysybrgreenpcr
AT stanleymargaret criticalevaluationofhpv16genecopynumberquantificationbysybrgreenpcr
AT herdmanmichaelt criticalevaluationofhpv16genecopynumberquantificationbysybrgreenpcr
AT pettmarkr criticalevaluationofhpv16genecopynumberquantificationbysybrgreenpcr
AT teschendorffandrew criticalevaluationofhpv16genecopynumberquantificationbysybrgreenpcr
AT colemannicholas criticalevaluationofhpv16genecopynumberquantificationbysybrgreenpcr