Protective ventilation in ARDS: as soon as possible. An immediate use of HFOV

OBJECTIVE: To report the immediate use of High-Frequency Oscillatory ventilation in an adult acute respiratory distress syndrome. DESIGN: Case report. SETTING: Intensive care unit at the Military Teaching Hospital of Toulon. PATIENT: A 64-yr-old Caucasian male who developed acute respiratory distres...

Descripción completa

Detalles Bibliográficos
Autores principales: Goutorbe, Philippe Ph, Asencio, Yves Y, Bordes, Julien J, Montcriol, Ambroise A, Prunet, Bertrand B, Meaudre, Eric E
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2535777/
https://www.ncbi.nlm.nih.gov/pubmed/18721463
http://dx.doi.org/10.1186/1757-1626-1-124
_version_ 1782159083906793472
author Goutorbe, Philippe Ph
Asencio, Yves Y
Bordes, Julien J
Montcriol, Ambroise A
Prunet, Bertrand B
Meaudre, Eric E
author_facet Goutorbe, Philippe Ph
Asencio, Yves Y
Bordes, Julien J
Montcriol, Ambroise A
Prunet, Bertrand B
Meaudre, Eric E
author_sort Goutorbe, Philippe Ph
collection PubMed
description OBJECTIVE: To report the immediate use of High-Frequency Oscillatory ventilation in an adult acute respiratory distress syndrome. DESIGN: Case report. SETTING: Intensive care unit at the Military Teaching Hospital of Toulon. PATIENT: A 64-yr-old Caucasian male who developed acute respiratory distress syndrome in the course of severe falciparum malaria. INTERVENTION: Initial use of HFO to minimise ventilator-induced lung injury. MEASUREMENT AND MAIN RESULTS: Rapid improvement of PaO2/fraction of inspired oxygen from 172 mmHg (NIV) to 310 mmHg with HFO. No ventilator-induced injury on CT scan after 5 days of invasive ventilation. CONCLUSION: In contrast with previous studies, we successfully used lung protective ventilation with HFO immediately. Further studies, with immediate, rather than rescue use of HFO ventilation, are needed.
format Text
id pubmed-2535777
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-25357772008-09-14 Protective ventilation in ARDS: as soon as possible. An immediate use of HFOV Goutorbe, Philippe Ph Asencio, Yves Y Bordes, Julien J Montcriol, Ambroise A Prunet, Bertrand B Meaudre, Eric E Cases J Case Report OBJECTIVE: To report the immediate use of High-Frequency Oscillatory ventilation in an adult acute respiratory distress syndrome. DESIGN: Case report. SETTING: Intensive care unit at the Military Teaching Hospital of Toulon. PATIENT: A 64-yr-old Caucasian male who developed acute respiratory distress syndrome in the course of severe falciparum malaria. INTERVENTION: Initial use of HFO to minimise ventilator-induced lung injury. MEASUREMENT AND MAIN RESULTS: Rapid improvement of PaO2/fraction of inspired oxygen from 172 mmHg (NIV) to 310 mmHg with HFO. No ventilator-induced injury on CT scan after 5 days of invasive ventilation. CONCLUSION: In contrast with previous studies, we successfully used lung protective ventilation with HFO immediately. Further studies, with immediate, rather than rescue use of HFO ventilation, are needed. BioMed Central 2008-08-22 /pmc/articles/PMC2535777/ /pubmed/18721463 http://dx.doi.org/10.1186/1757-1626-1-124 Text en Copyright © 2008 Goutorbe et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Goutorbe, Philippe Ph
Asencio, Yves Y
Bordes, Julien J
Montcriol, Ambroise A
Prunet, Bertrand B
Meaudre, Eric E
Protective ventilation in ARDS: as soon as possible. An immediate use of HFOV
title Protective ventilation in ARDS: as soon as possible. An immediate use of HFOV
title_full Protective ventilation in ARDS: as soon as possible. An immediate use of HFOV
title_fullStr Protective ventilation in ARDS: as soon as possible. An immediate use of HFOV
title_full_unstemmed Protective ventilation in ARDS: as soon as possible. An immediate use of HFOV
title_short Protective ventilation in ARDS: as soon as possible. An immediate use of HFOV
title_sort protective ventilation in ards: as soon as possible. an immediate use of hfov
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2535777/
https://www.ncbi.nlm.nih.gov/pubmed/18721463
http://dx.doi.org/10.1186/1757-1626-1-124
work_keys_str_mv AT goutorbephilippeph protectiveventilationinardsassoonaspossibleanimmediateuseofhfov
AT asencioyvesy protectiveventilationinardsassoonaspossibleanimmediateuseofhfov
AT bordesjulienj protectiveventilationinardsassoonaspossibleanimmediateuseofhfov
AT montcriolambroisea protectiveventilationinardsassoonaspossibleanimmediateuseofhfov
AT prunetbertrandb protectiveventilationinardsassoonaspossibleanimmediateuseofhfov
AT meaudreerice protectiveventilationinardsassoonaspossibleanimmediateuseofhfov