Cargando…

Accuracy of biplane x-ray imaging combined with model-based tracking for measuring in-vivo patellofemoral joint motion

BACKGROUND: Accurately measuring in-vivo motion of the knee's patellofemoral (PF) joint is challenging. Conventional measurement techniques have largely been unable to accurately measure three-dimensional, in-vivo motion of the patella during dynamic activities. The purpose of this study was to...

Descripción completa

Detalles Bibliográficos
Autores principales: Bey, Michael J, Kline, Stephanie K, Tashman, Scott, Zauel, Roger
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2538511/
https://www.ncbi.nlm.nih.gov/pubmed/18771582
http://dx.doi.org/10.1186/1749-799X-3-38
_version_ 1782159116556304384
author Bey, Michael J
Kline, Stephanie K
Tashman, Scott
Zauel, Roger
author_facet Bey, Michael J
Kline, Stephanie K
Tashman, Scott
Zauel, Roger
author_sort Bey, Michael J
collection PubMed
description BACKGROUND: Accurately measuring in-vivo motion of the knee's patellofemoral (PF) joint is challenging. Conventional measurement techniques have largely been unable to accurately measure three-dimensional, in-vivo motion of the patella during dynamic activities. The purpose of this study was to assess the accuracy of a new model-based technique for measuring PF joint motion. METHODS: To assess the accuracy of this technique, we implanted tantalum beads into the femur and patella of three cadaveric knee specimens and then recorded dynamic biplane radiographic images while manually flexing and extending the specimen. The position of the femur and patella were measured from the biplane images using both the model-based tracking system and a validated dynamic radiostereometric analysis (RSA) technique. Model-based tracking was compared to dynamic RSA by computing measures of bias, precision, and overall dynamic accuracy of four clinically-relevant kinematic parameters (patellar shift, flexion, tilt, and rotation). RESULTS: The model-based tracking technique results were in excellent agreement with the RSA technique. Overall dynamic accuracy indicated errors of less than 0.395 mm for patellar shift, 0.875° for flexion, 0.863° for tilt, and 0.877° for rotation. CONCLUSION: This model-based tracking technique is a non-invasive method for accurately measuring dynamic PF joint motion under in-vivo conditions. The technique is sufficiently accurate in measuring clinically relevant changes in PF joint motion following conservative or surgical treatment.
format Text
id pubmed-2538511
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-25385112008-09-17 Accuracy of biplane x-ray imaging combined with model-based tracking for measuring in-vivo patellofemoral joint motion Bey, Michael J Kline, Stephanie K Tashman, Scott Zauel, Roger J Orthop Surg Technical Note BACKGROUND: Accurately measuring in-vivo motion of the knee's patellofemoral (PF) joint is challenging. Conventional measurement techniques have largely been unable to accurately measure three-dimensional, in-vivo motion of the patella during dynamic activities. The purpose of this study was to assess the accuracy of a new model-based technique for measuring PF joint motion. METHODS: To assess the accuracy of this technique, we implanted tantalum beads into the femur and patella of three cadaveric knee specimens and then recorded dynamic biplane radiographic images while manually flexing and extending the specimen. The position of the femur and patella were measured from the biplane images using both the model-based tracking system and a validated dynamic radiostereometric analysis (RSA) technique. Model-based tracking was compared to dynamic RSA by computing measures of bias, precision, and overall dynamic accuracy of four clinically-relevant kinematic parameters (patellar shift, flexion, tilt, and rotation). RESULTS: The model-based tracking technique results were in excellent agreement with the RSA technique. Overall dynamic accuracy indicated errors of less than 0.395 mm for patellar shift, 0.875° for flexion, 0.863° for tilt, and 0.877° for rotation. CONCLUSION: This model-based tracking technique is a non-invasive method for accurately measuring dynamic PF joint motion under in-vivo conditions. The technique is sufficiently accurate in measuring clinically relevant changes in PF joint motion following conservative or surgical treatment. BioMed Central 2008-09-04 /pmc/articles/PMC2538511/ /pubmed/18771582 http://dx.doi.org/10.1186/1749-799X-3-38 Text en Copyright © 2008 Bey et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Note
Bey, Michael J
Kline, Stephanie K
Tashman, Scott
Zauel, Roger
Accuracy of biplane x-ray imaging combined with model-based tracking for measuring in-vivo patellofemoral joint motion
title Accuracy of biplane x-ray imaging combined with model-based tracking for measuring in-vivo patellofemoral joint motion
title_full Accuracy of biplane x-ray imaging combined with model-based tracking for measuring in-vivo patellofemoral joint motion
title_fullStr Accuracy of biplane x-ray imaging combined with model-based tracking for measuring in-vivo patellofemoral joint motion
title_full_unstemmed Accuracy of biplane x-ray imaging combined with model-based tracking for measuring in-vivo patellofemoral joint motion
title_short Accuracy of biplane x-ray imaging combined with model-based tracking for measuring in-vivo patellofemoral joint motion
title_sort accuracy of biplane x-ray imaging combined with model-based tracking for measuring in-vivo patellofemoral joint motion
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2538511/
https://www.ncbi.nlm.nih.gov/pubmed/18771582
http://dx.doi.org/10.1186/1749-799X-3-38
work_keys_str_mv AT beymichaelj accuracyofbiplanexrayimagingcombinedwithmodelbasedtrackingformeasuringinvivopatellofemoraljointmotion
AT klinestephaniek accuracyofbiplanexrayimagingcombinedwithmodelbasedtrackingformeasuringinvivopatellofemoraljointmotion
AT tashmanscott accuracyofbiplanexrayimagingcombinedwithmodelbasedtrackingformeasuringinvivopatellofemoraljointmotion
AT zauelroger accuracyofbiplanexrayimagingcombinedwithmodelbasedtrackingformeasuringinvivopatellofemoraljointmotion