Cargando…

Normalization of flow-mediated dilation to shear stress area under the curve eliminates the impact of variable hyperemic stimulus

BACKGROUND: Normalization of brachial artery flow-mediated dilation (FMD) to individual shear stress area under the curve (peak FMD:SS(AUC )ratio) has recently been proposed as an approach to control for the large inter-subject variability in reactive hyperemia-induced shear stress; however, the ado...

Descripción completa

Detalles Bibliográficos
Autores principales: Padilla, Jaume, Johnson, Blair D, Newcomer, Sean C, Wilhite, Daniel P, Mickleborough, Timothy D, Fly, Alyce D, Mather, Kieren J, Wallace, Janet P
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2542351/
https://www.ncbi.nlm.nih.gov/pubmed/18771594
http://dx.doi.org/10.1186/1476-7120-6-44
_version_ 1782159137571864576
author Padilla, Jaume
Johnson, Blair D
Newcomer, Sean C
Wilhite, Daniel P
Mickleborough, Timothy D
Fly, Alyce D
Mather, Kieren J
Wallace, Janet P
author_facet Padilla, Jaume
Johnson, Blair D
Newcomer, Sean C
Wilhite, Daniel P
Mickleborough, Timothy D
Fly, Alyce D
Mather, Kieren J
Wallace, Janet P
author_sort Padilla, Jaume
collection PubMed
description BACKGROUND: Normalization of brachial artery flow-mediated dilation (FMD) to individual shear stress area under the curve (peak FMD:SS(AUC )ratio) has recently been proposed as an approach to control for the large inter-subject variability in reactive hyperemia-induced shear stress; however, the adoption of this approach among researchers has been slow. The present study was designed to further examine the efficacy of FMD normalization to shear stress in reducing measurement variability. METHODS: Five different magnitudes of reactive hyperemia-induced shear stress were applied to 20 healthy, physically active young adults (25.3 ± 0. 6 yrs; 10 men, 10 women) by manipulating forearm cuff occlusion duration: 1, 2, 3, 4, and 5 min, in a randomized order. A venous blood draw was performed for determination of baseline whole blood viscosity and hematocrit. The magnitude of occlusion-induced forearm ischemia was quantified by dual-wavelength near-infrared spectrometry (NIRS). Brachial artery diameters and velocities were obtained via high-resolution ultrasound. The SS(AUC )was individually calculated for the duration of time-to-peak dilation. RESULTS: One-way repeated measures ANOVA demonstrated distinct magnitudes of occlusion-induced ischemia (volume and peak), hyperemic shear stress, and peak FMD responses (all p < 0.0001) across forearm occlusion durations. Differences in peak FMD were abolished when normalizing FMD to SS(AUC )(p = 0.785). CONCLUSION: Our data confirm that normalization of FMD to SS(AUC )eliminates the influences of variable shear stress and solidifies the utility of FMD:SS(AUC )ratio as an index of endothelial function.
format Text
id pubmed-2542351
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-25423512008-09-18 Normalization of flow-mediated dilation to shear stress area under the curve eliminates the impact of variable hyperemic stimulus Padilla, Jaume Johnson, Blair D Newcomer, Sean C Wilhite, Daniel P Mickleborough, Timothy D Fly, Alyce D Mather, Kieren J Wallace, Janet P Cardiovasc Ultrasound Research BACKGROUND: Normalization of brachial artery flow-mediated dilation (FMD) to individual shear stress area under the curve (peak FMD:SS(AUC )ratio) has recently been proposed as an approach to control for the large inter-subject variability in reactive hyperemia-induced shear stress; however, the adoption of this approach among researchers has been slow. The present study was designed to further examine the efficacy of FMD normalization to shear stress in reducing measurement variability. METHODS: Five different magnitudes of reactive hyperemia-induced shear stress were applied to 20 healthy, physically active young adults (25.3 ± 0. 6 yrs; 10 men, 10 women) by manipulating forearm cuff occlusion duration: 1, 2, 3, 4, and 5 min, in a randomized order. A venous blood draw was performed for determination of baseline whole blood viscosity and hematocrit. The magnitude of occlusion-induced forearm ischemia was quantified by dual-wavelength near-infrared spectrometry (NIRS). Brachial artery diameters and velocities were obtained via high-resolution ultrasound. The SS(AUC )was individually calculated for the duration of time-to-peak dilation. RESULTS: One-way repeated measures ANOVA demonstrated distinct magnitudes of occlusion-induced ischemia (volume and peak), hyperemic shear stress, and peak FMD responses (all p < 0.0001) across forearm occlusion durations. Differences in peak FMD were abolished when normalizing FMD to SS(AUC )(p = 0.785). CONCLUSION: Our data confirm that normalization of FMD to SS(AUC )eliminates the influences of variable shear stress and solidifies the utility of FMD:SS(AUC )ratio as an index of endothelial function. BioMed Central 2008-09-04 /pmc/articles/PMC2542351/ /pubmed/18771594 http://dx.doi.org/10.1186/1476-7120-6-44 Text en Copyright © 2008 Padilla et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Padilla, Jaume
Johnson, Blair D
Newcomer, Sean C
Wilhite, Daniel P
Mickleborough, Timothy D
Fly, Alyce D
Mather, Kieren J
Wallace, Janet P
Normalization of flow-mediated dilation to shear stress area under the curve eliminates the impact of variable hyperemic stimulus
title Normalization of flow-mediated dilation to shear stress area under the curve eliminates the impact of variable hyperemic stimulus
title_full Normalization of flow-mediated dilation to shear stress area under the curve eliminates the impact of variable hyperemic stimulus
title_fullStr Normalization of flow-mediated dilation to shear stress area under the curve eliminates the impact of variable hyperemic stimulus
title_full_unstemmed Normalization of flow-mediated dilation to shear stress area under the curve eliminates the impact of variable hyperemic stimulus
title_short Normalization of flow-mediated dilation to shear stress area under the curve eliminates the impact of variable hyperemic stimulus
title_sort normalization of flow-mediated dilation to shear stress area under the curve eliminates the impact of variable hyperemic stimulus
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2542351/
https://www.ncbi.nlm.nih.gov/pubmed/18771594
http://dx.doi.org/10.1186/1476-7120-6-44
work_keys_str_mv AT padillajaume normalizationofflowmediateddilationtoshearstressareaunderthecurveeliminatestheimpactofvariablehyperemicstimulus
AT johnsonblaird normalizationofflowmediateddilationtoshearstressareaunderthecurveeliminatestheimpactofvariablehyperemicstimulus
AT newcomerseanc normalizationofflowmediateddilationtoshearstressareaunderthecurveeliminatestheimpactofvariablehyperemicstimulus
AT wilhitedanielp normalizationofflowmediateddilationtoshearstressareaunderthecurveeliminatestheimpactofvariablehyperemicstimulus
AT mickleboroughtimothyd normalizationofflowmediateddilationtoshearstressareaunderthecurveeliminatestheimpactofvariablehyperemicstimulus
AT flyalyced normalizationofflowmediateddilationtoshearstressareaunderthecurveeliminatestheimpactofvariablehyperemicstimulus
AT matherkierenj normalizationofflowmediateddilationtoshearstressareaunderthecurveeliminatestheimpactofvariablehyperemicstimulus
AT wallacejanetp normalizationofflowmediateddilationtoshearstressareaunderthecurveeliminatestheimpactofvariablehyperemicstimulus