Cargando…

Simultaneous versus video counting of coughs in hypertonic cough challenges

BACKGROUND: The coughs occurring during cough provocation tests are usually counted at the same time when the test is being conducted, i.e., simultaneously. It is unknown whether cough counting from video recording might increase the accuracy of the cough counting. During recent years, cough challen...

Descripción completa

Detalles Bibliográficos
Autores principales: Koskela, Heikki O, Purokivi, Minna K, Tukiainen, Raija M
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2542393/
https://www.ncbi.nlm.nih.gov/pubmed/18782429
http://dx.doi.org/10.1186/1745-9974-4-8
_version_ 1782159147334107136
author Koskela, Heikki O
Purokivi, Minna K
Tukiainen, Raija M
author_facet Koskela, Heikki O
Purokivi, Minna K
Tukiainen, Raija M
author_sort Koskela, Heikki O
collection PubMed
description BACKGROUND: The coughs occurring during cough provocation tests are usually counted at the same time when the test is being conducted, i.e., simultaneously. It is unknown whether cough counting from video recording might increase the accuracy of the cough counting. During recent years, cough challenges with hypertonic aerosols have been introduced. They often provoke very frequent coughing which may complicate the simultaneous cough counting. OBJECTIVE: To assess whether cough counting from video recording is superior to simultaneous cough counting in two different hypertonic cough challenges. METHODS: The analysis includes 82 hypertonic saline challenges performed on 66 subjects, providing 1984 observation minutes with both simultaneous and video cough counting. The cough sensitivity was expressed as the osmolality to provoke 15 cumulative coughs (CUM15). The analysis also includes 136 hypertonic histamine challenges performed on 114 subjects providing 5373 observation minutes with both simultaneous and video counting. The cough sensitivity was expressed as the cumulative number of coughs divided by the final histamine concentration administered (CCR). This challenge involved several additional measurements to cough counting. RESULTS: For the saline challenge, the mean difference between the counting types was 0.0 coughs per minute with 95% limits of agreement of -1.2 to 1.2 coughs per minute. For the hypertonic histamine challenge the respective figures were 0.3 (-1.9 to 2.5) coughs per minute. At high coughing frequency the video counts tended to outnumber the simultaneous counts. The counting type had no effect on the hypertonic saline CUM15 and only a marginal effect on its repeatability. On the contrary, video counting resulted to significantly higher hypertonic histamine CCR values than simultaneous counting (p < 0.001). CONCLUSION: The agreement between simultaneous and video counting of coughs is generally good. However, as the coughing frequency increases, simultaneous counting may miss coughs, especially if the nurse has to share his/her attention to several activities simultaneously. Video recording is advisable for the hypertonic histamine challenge but unnecessary for the hypertonic saline challenge. To ensure reliable simultaneous cough counting, cough provocation tests should be performed in a quiet environment, applying as little unnecessary equipment and measurements as possible.
format Text
id pubmed-2542393
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-25423932008-09-18 Simultaneous versus video counting of coughs in hypertonic cough challenges Koskela, Heikki O Purokivi, Minna K Tukiainen, Raija M Cough Research BACKGROUND: The coughs occurring during cough provocation tests are usually counted at the same time when the test is being conducted, i.e., simultaneously. It is unknown whether cough counting from video recording might increase the accuracy of the cough counting. During recent years, cough challenges with hypertonic aerosols have been introduced. They often provoke very frequent coughing which may complicate the simultaneous cough counting. OBJECTIVE: To assess whether cough counting from video recording is superior to simultaneous cough counting in two different hypertonic cough challenges. METHODS: The analysis includes 82 hypertonic saline challenges performed on 66 subjects, providing 1984 observation minutes with both simultaneous and video cough counting. The cough sensitivity was expressed as the osmolality to provoke 15 cumulative coughs (CUM15). The analysis also includes 136 hypertonic histamine challenges performed on 114 subjects providing 5373 observation minutes with both simultaneous and video counting. The cough sensitivity was expressed as the cumulative number of coughs divided by the final histamine concentration administered (CCR). This challenge involved several additional measurements to cough counting. RESULTS: For the saline challenge, the mean difference between the counting types was 0.0 coughs per minute with 95% limits of agreement of -1.2 to 1.2 coughs per minute. For the hypertonic histamine challenge the respective figures were 0.3 (-1.9 to 2.5) coughs per minute. At high coughing frequency the video counts tended to outnumber the simultaneous counts. The counting type had no effect on the hypertonic saline CUM15 and only a marginal effect on its repeatability. On the contrary, video counting resulted to significantly higher hypertonic histamine CCR values than simultaneous counting (p < 0.001). CONCLUSION: The agreement between simultaneous and video counting of coughs is generally good. However, as the coughing frequency increases, simultaneous counting may miss coughs, especially if the nurse has to share his/her attention to several activities simultaneously. Video recording is advisable for the hypertonic histamine challenge but unnecessary for the hypertonic saline challenge. To ensure reliable simultaneous cough counting, cough provocation tests should be performed in a quiet environment, applying as little unnecessary equipment and measurements as possible. BioMed Central 2008-09-09 /pmc/articles/PMC2542393/ /pubmed/18782429 http://dx.doi.org/10.1186/1745-9974-4-8 Text en Copyright © 2008 Koskela et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Koskela, Heikki O
Purokivi, Minna K
Tukiainen, Raija M
Simultaneous versus video counting of coughs in hypertonic cough challenges
title Simultaneous versus video counting of coughs in hypertonic cough challenges
title_full Simultaneous versus video counting of coughs in hypertonic cough challenges
title_fullStr Simultaneous versus video counting of coughs in hypertonic cough challenges
title_full_unstemmed Simultaneous versus video counting of coughs in hypertonic cough challenges
title_short Simultaneous versus video counting of coughs in hypertonic cough challenges
title_sort simultaneous versus video counting of coughs in hypertonic cough challenges
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2542393/
https://www.ncbi.nlm.nih.gov/pubmed/18782429
http://dx.doi.org/10.1186/1745-9974-4-8
work_keys_str_mv AT koskelaheikkio simultaneousversusvideocountingofcoughsinhypertoniccoughchallenges
AT purokiviminnak simultaneousversusvideocountingofcoughsinhypertoniccoughchallenges
AT tukiainenraijam simultaneousversusvideocountingofcoughsinhypertoniccoughchallenges