A novel approach to non-segmented flow analysis: Part 3. Nitrate, nitrite and ammonium in waters
A high-performance continuous-flow analyser is used for the analysis of nitrate, nitrite and ammonium ion in potable waters. The results demonstrate that (1) the analyser allows the sequential determination of a number of analytes without requiring modification to the manifold; (2) the use of progra...
Autores principales: | , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
1988
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2547757/ https://www.ncbi.nlm.nih.gov/pubmed/18925215 http://dx.doi.org/10.1155/S1463924688000410 |
Sumario: | A high-performance continuous-flow analyser is used for the analysis of nitrate, nitrite and ammonium ion in potable waters. The results demonstrate that (1) the analyser allows the sequential determination of a number of analytes without requiring modification to the manifold; (2) the use of programmed slicing of the reaction mixture allows a wide range of analyte concentrations to be handled; and (3) that the sensitivity achieved compares favourably with the best available from conventional flow-injection analysis. The limits of detection were found to be 5 ppb for NH(4) (+), 30 ppb for NO(3) (-), and 4 ppb for NO(2) (-). |
---|