Cargando…

Adaptation of a cold vapour mercury analyser to flow injection analysis

Minor modifications to a Coleman MAS-50A Mercury Analyser System allowed the determination of mercury by flow injection analysis. Using sample volumes of 600 μl it was possible to analyse up to 120 samples per hour, with a detection limit of 0.2 μg. l(-1) (120 pg) of mercury. The authors also report...

Descripción completa

Detalles Bibliográficos
Autores principales: Pasquini, Celio, Jardim, Wilson F., de Faria, Lourival C.
Formato: Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 1988
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2547765/
https://www.ncbi.nlm.nih.gov/pubmed/18925214
http://dx.doi.org/10.1155/S1463924688000409
_version_ 1782159334496534528
author Pasquini, Celio
Jardim, Wilson F.
de Faria, Lourival C.
author_facet Pasquini, Celio
Jardim, Wilson F.
de Faria, Lourival C.
author_sort Pasquini, Celio
collection PubMed
description Minor modifications to a Coleman MAS-50A Mercury Analyser System allowed the determination of mercury by flow injection analysis. Using sample volumes of 600 μl it was possible to analyse up to 120 samples per hour, with a detection limit of 0.2 μg. l(-1) (120 pg) of mercury. The authors also report on a simple digestion procedure which replaces the time- and reagent-consuming EPA procedure, when the sample content permits.
format Text
id pubmed-2547765
institution National Center for Biotechnology Information
language English
publishDate 1988
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-25477652008-10-16 Adaptation of a cold vapour mercury analyser to flow injection analysis Pasquini, Celio Jardim, Wilson F. de Faria, Lourival C. J Automat Chem Research Article Minor modifications to a Coleman MAS-50A Mercury Analyser System allowed the determination of mercury by flow injection analysis. Using sample volumes of 600 μl it was possible to analyse up to 120 samples per hour, with a detection limit of 0.2 μg. l(-1) (120 pg) of mercury. The authors also report on a simple digestion procedure which replaces the time- and reagent-consuming EPA procedure, when the sample content permits. Hindawi Publishing Corporation 1988 /pmc/articles/PMC2547765/ /pubmed/18925214 http://dx.doi.org/10.1155/S1463924688000409 Text en Copyright © 1988 Hindawi Publishing Corporation. http://creativecommons.org/licenses/by/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Pasquini, Celio
Jardim, Wilson F.
de Faria, Lourival C.
Adaptation of a cold vapour mercury analyser to flow injection analysis
title Adaptation of a cold vapour mercury analyser to flow injection analysis
title_full Adaptation of a cold vapour mercury analyser to flow injection analysis
title_fullStr Adaptation of a cold vapour mercury analyser to flow injection analysis
title_full_unstemmed Adaptation of a cold vapour mercury analyser to flow injection analysis
title_short Adaptation of a cold vapour mercury analyser to flow injection analysis
title_sort adaptation of a cold vapour mercury analyser to flow injection analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2547765/
https://www.ncbi.nlm.nih.gov/pubmed/18925214
http://dx.doi.org/10.1155/S1463924688000409
work_keys_str_mv AT pasquinicelio adaptationofacoldvapourmercuryanalysertoflowinjectionanalysis
AT jardimwilsonf adaptationofacoldvapourmercuryanalysertoflowinjectionanalysis
AT defarialourivalc adaptationofacoldvapourmercuryanalysertoflowinjectionanalysis