Determination of specific proteins by the FIA principle

The following analytes have been investigated: urine albumin (u-albumin), plasma-transferrin (p-transferrin), p-haptoglobin, p-IgG, p-IgA, p-IgM, and p-orosomucoid. An unmodified commercial analytical system FIA Star (Tecator) with a two-channel injector (40 μl) was used. The prediluted plasma sampl...

Descripción completa

Detalles Bibliográficos
Autor principal: Andersen, Ib
Formato: Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 1990
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2547837/
https://www.ncbi.nlm.nih.gov/pubmed/18925279
http://dx.doi.org/10.1155/S1463924690000074
_version_ 1782159351395385344
author Andersen, Ib
author_facet Andersen, Ib
author_sort Andersen, Ib
collection PubMed
description The following analytes have been investigated: urine albumin (u-albumin), plasma-transferrin (p-transferrin), p-haptoglobin, p-IgG, p-IgA, p-IgM, and p-orosomucoid. An unmodified commercial analytical system FIA Star (Tecator) with a two-channel injector (40 μl) was used. The prediluted plasma samples and antibodies are allowed to react for 33 s before the change in turbidity is measured as a Peak maximum at 405 nm. The optimal concentrations of calibrators and antibodies have been determined to secure antibody excess. Response time (i.e. delay between aspiration of a sample and presentation of the result in absorption units) is 75 s. Automatic print-out of the absorbance profile and movement of the sample rack further accounted for 21 s per sample, so the throughput is reduced to 75 determinations per 2 h. Results are available within an hour, compared to two-12 days with the present methods (electroimmunoassays). Parallel analyses with established methods/analysers show excellent agreement for u-albumin, p-transferrin and p-haptoglobin. For p-IgG, p-IgA and p-IgM the reaction time of 33 s is insufficient because their relative molecular masses (i.e. the size of the molecules) are so high, 150.000-971.000. Five minutes is a more adequate reaction time, which makes a serial analyser such as FIA Star unsuitable for larger workloads of samples of immunoglobulins. The plasma concentration of Orosomucoid is low, resulting in high sample blanks. It is therefore recommended that the reaction is followed kinetically if a serial analyser is used.
format Text
id pubmed-2547837
institution National Center for Biotechnology Information
language English
publishDate 1990
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-25478372008-10-16 Determination of specific proteins by the FIA principle Andersen, Ib J Automat Chem Research Article The following analytes have been investigated: urine albumin (u-albumin), plasma-transferrin (p-transferrin), p-haptoglobin, p-IgG, p-IgA, p-IgM, and p-orosomucoid. An unmodified commercial analytical system FIA Star (Tecator) with a two-channel injector (40 μl) was used. The prediluted plasma samples and antibodies are allowed to react for 33 s before the change in turbidity is measured as a Peak maximum at 405 nm. The optimal concentrations of calibrators and antibodies have been determined to secure antibody excess. Response time (i.e. delay between aspiration of a sample and presentation of the result in absorption units) is 75 s. Automatic print-out of the absorbance profile and movement of the sample rack further accounted for 21 s per sample, so the throughput is reduced to 75 determinations per 2 h. Results are available within an hour, compared to two-12 days with the present methods (electroimmunoassays). Parallel analyses with established methods/analysers show excellent agreement for u-albumin, p-transferrin and p-haptoglobin. For p-IgG, p-IgA and p-IgM the reaction time of 33 s is insufficient because their relative molecular masses (i.e. the size of the molecules) are so high, 150.000-971.000. Five minutes is a more adequate reaction time, which makes a serial analyser such as FIA Star unsuitable for larger workloads of samples of immunoglobulins. The plasma concentration of Orosomucoid is low, resulting in high sample blanks. It is therefore recommended that the reaction is followed kinetically if a serial analyser is used. Hindawi Publishing Corporation 1990 /pmc/articles/PMC2547837/ /pubmed/18925279 http://dx.doi.org/10.1155/S1463924690000074 Text en Copyright © 1990 Hindawi Publishing Corporation. http://creativecommons.org/licenses/by/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Andersen, Ib
Determination of specific proteins by the FIA principle
title Determination of specific proteins by the FIA principle
title_full Determination of specific proteins by the FIA principle
title_fullStr Determination of specific proteins by the FIA principle
title_full_unstemmed Determination of specific proteins by the FIA principle
title_short Determination of specific proteins by the FIA principle
title_sort determination of specific proteins by the fia principle
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2547837/
https://www.ncbi.nlm.nih.gov/pubmed/18925279
http://dx.doi.org/10.1155/S1463924690000074
work_keys_str_mv AT andersenib determinationofspecificproteinsbythefiaprinciple