Evaluation of the Technicon Axon analyser

An evaluation of the Technicon Axon analyser was carried out following the guidelines of the ‘Sociedad Española de Química Clínica’ and the European Committee for Clinical Laboratory Standards. A photometric study revealed acceptable results at both 340 nm and 404 nm. Inaccuracy and imprecision were...

Descripción completa

Detalles Bibliográficos
Autores principales: Martínez, C., Márquez, M., Cortés, M., Mercé, J., Rodriguez, J., González, F.
Formato: Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 1990
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2547842/
https://www.ncbi.nlm.nih.gov/pubmed/18925282
http://dx.doi.org/10.1155/S1463924690000311
_version_ 1782159352573984768
author Martínez, C.
Márquez, M.
Cortés, M.
Mercé, J.
Rodriguez, J.
González, F.
author_facet Martínez, C.
Márquez, M.
Cortés, M.
Mercé, J.
Rodriguez, J.
González, F.
author_sort Martínez, C.
collection PubMed
description An evaluation of the Technicon Axon analyser was carried out following the guidelines of the ‘Sociedad Española de Química Clínica’ and the European Committee for Clinical Laboratory Standards. A photometric study revealed acceptable results at both 340 nm and 404 nm. Inaccuracy and imprecision were lower at 404 nm than at 340 nm, although poor dispersion was found at both wavelengths, even at low absorbances. Drift was negligible, the imprecision of the sample pipette delivery system was greater for small sample volumes, the reagent pipette delivery system imprecision was acceptable and the sample diluting system study showed good precision and accuracy. Twelve analytes were studied for evaluation of the analyser under routine working conditions. Satisfactory results were obtained for within-run imprecision, while coefficients of variation for betweenrun imprecision were much greater than expected. Neither specimenrelated nor specimen-independent contamination was found in the carry-over study. For all analytes assayed, when comparing patient sample results with those obtained in a Hitachi 737 analyser, acceptable relative inaccuracy was observed.
format Text
id pubmed-2547842
institution National Center for Biotechnology Information
language English
publishDate 1990
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-25478422008-10-16 Evaluation of the Technicon Axon analyser Martínez, C. Márquez, M. Cortés, M. Mercé, J. Rodriguez, J. González, F. J Automat Chem Research Article An evaluation of the Technicon Axon analyser was carried out following the guidelines of the ‘Sociedad Española de Química Clínica’ and the European Committee for Clinical Laboratory Standards. A photometric study revealed acceptable results at both 340 nm and 404 nm. Inaccuracy and imprecision were lower at 404 nm than at 340 nm, although poor dispersion was found at both wavelengths, even at low absorbances. Drift was negligible, the imprecision of the sample pipette delivery system was greater for small sample volumes, the reagent pipette delivery system imprecision was acceptable and the sample diluting system study showed good precision and accuracy. Twelve analytes were studied for evaluation of the analyser under routine working conditions. Satisfactory results were obtained for within-run imprecision, while coefficients of variation for betweenrun imprecision were much greater than expected. Neither specimenrelated nor specimen-independent contamination was found in the carry-over study. For all analytes assayed, when comparing patient sample results with those obtained in a Hitachi 737 analyser, acceptable relative inaccuracy was observed. Hindawi Publishing Corporation 1990 /pmc/articles/PMC2547842/ /pubmed/18925282 http://dx.doi.org/10.1155/S1463924690000311 Text en Copyright © 1990 Hindawi Publishing Corporation. http://creativecommons.org/licenses/by/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Martínez, C.
Márquez, M.
Cortés, M.
Mercé, J.
Rodriguez, J.
González, F.
Evaluation of the Technicon Axon analyser
title Evaluation of the Technicon Axon analyser
title_full Evaluation of the Technicon Axon analyser
title_fullStr Evaluation of the Technicon Axon analyser
title_full_unstemmed Evaluation of the Technicon Axon analyser
title_short Evaluation of the Technicon Axon analyser
title_sort evaluation of the technicon axon analyser
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2547842/
https://www.ncbi.nlm.nih.gov/pubmed/18925282
http://dx.doi.org/10.1155/S1463924690000311
work_keys_str_mv AT martinezc evaluationofthetechniconaxonanalyser
AT marquezm evaluationofthetechniconaxonanalyser
AT cortesm evaluationofthetechniconaxonanalyser
AT mercej evaluationofthetechniconaxonanalyser
AT rodriguezj evaluationofthetechniconaxonanalyser
AT gonzalezf evaluationofthetechniconaxonanalyser