Cargando…

A computer-controlled data acquisition and analysis system for use in the characterization of plasma atomic emission sources

The characterization of new spectroscopic plasma sources for use in atomic emission spectroscopy often presents the need for information about the spatial emission characteristics of the source. In addition, information about the variation of the emission over time is often beneficial. It is also us...

Descripción completa

Detalles Bibliográficos
Autores principales: Shields, James P., Piepmeier, Edward H.
Formato: Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 1991
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2547924/
https://www.ncbi.nlm.nih.gov/pubmed/18924897
http://dx.doi.org/10.1155/S1463924691000251
_version_ 1782159364519362560
author Shields, James P.
Piepmeier, Edward H.
author_facet Shields, James P.
Piepmeier, Edward H.
author_sort Shields, James P.
collection PubMed
description The characterization of new spectroscopic plasma sources for use in atomic emission spectroscopy often presents the need for information about the spatial emission characteristics of the source. In addition, information about the variation of the emission over time is often beneficial. It is also useful to be able to graphically see, in real-time, the effects of varying a particular experimental parameter. This paper describes a flexible data acquisition system in which an echelle spectrometer is interfaced to an IBM-PC compatible microcomputer. The FORTH-based ASYST software, which proves real-time display of acquired data, allows any point in the emission source to be imaged on the entrance slit of the spectrometer by using the cursor keys of the PC and a computer-controlled mirror. The different acquisition modes of the system are illustrated with examples of two-dimensional spatial profiles of the plasma and monitoring of plasma stability over time. In addition, an illustration of the optimization of the echelle's aperture plate and photomultiplier tube positions in the focal plane is presented.
format Text
id pubmed-2547924
institution National Center for Biotechnology Information
language English
publishDate 1991
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-25479242008-10-16 A computer-controlled data acquisition and analysis system for use in the characterization of plasma atomic emission sources Shields, James P. Piepmeier, Edward H. J Automat Chem Research Article The characterization of new spectroscopic plasma sources for use in atomic emission spectroscopy often presents the need for information about the spatial emission characteristics of the source. In addition, information about the variation of the emission over time is often beneficial. It is also useful to be able to graphically see, in real-time, the effects of varying a particular experimental parameter. This paper describes a flexible data acquisition system in which an echelle spectrometer is interfaced to an IBM-PC compatible microcomputer. The FORTH-based ASYST software, which proves real-time display of acquired data, allows any point in the emission source to be imaged on the entrance slit of the spectrometer by using the cursor keys of the PC and a computer-controlled mirror. The different acquisition modes of the system are illustrated with examples of two-dimensional spatial profiles of the plasma and monitoring of plasma stability over time. In addition, an illustration of the optimization of the echelle's aperture plate and photomultiplier tube positions in the focal plane is presented. Hindawi Publishing Corporation 1991 /pmc/articles/PMC2547924/ /pubmed/18924897 http://dx.doi.org/10.1155/S1463924691000251 Text en Copyright © 1991 Hindawi Publishing Corporation. http://creativecommons.org/licenses/by/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Shields, James P.
Piepmeier, Edward H.
A computer-controlled data acquisition and analysis system for use in the characterization of plasma atomic emission sources
title A computer-controlled data acquisition and analysis system for use in the characterization of plasma atomic emission sources
title_full A computer-controlled data acquisition and analysis system for use in the characterization of plasma atomic emission sources
title_fullStr A computer-controlled data acquisition and analysis system for use in the characterization of plasma atomic emission sources
title_full_unstemmed A computer-controlled data acquisition and analysis system for use in the characterization of plasma atomic emission sources
title_short A computer-controlled data acquisition and analysis system for use in the characterization of plasma atomic emission sources
title_sort computer-controlled data acquisition and analysis system for use in the characterization of plasma atomic emission sources
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2547924/
https://www.ncbi.nlm.nih.gov/pubmed/18924897
http://dx.doi.org/10.1155/S1463924691000251
work_keys_str_mv AT shieldsjamesp acomputercontrolleddataacquisitionandanalysissystemforuseinthecharacterizationofplasmaatomicemissionsources
AT piepmeieredwardh acomputercontrolleddataacquisitionandanalysissystemforuseinthecharacterizationofplasmaatomicemissionsources
AT shieldsjamesp computercontrolleddataacquisitionandanalysissystemforuseinthecharacterizationofplasmaatomicemissionsources
AT piepmeieredwardh computercontrolleddataacquisitionandanalysissystemforuseinthecharacterizationofplasmaatomicemissionsources