Automation of flow injection gas diffusion-ion chromatography for the nanomolar determination of methylamines and ammonia in seawater and atmospheric samples

The automation and improved design and performance of Flow Injection Gas Diffusion-Ion Chromatography (FIGD-IC), a novel technique for the simultaneous analysis of trace ammonia (NH(3)) and methylamines (MAs) in aqueous media, is presented. Automated Flow Injection Gas Diffusion (FIGD) promotes the...

Descripción completa

Detalles Bibliográficos
Autores principales: Gibb, Stuart W., Wood, John W., Fauzi, R., Mantoura, C.
Formato: Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 1995
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2548102/
https://www.ncbi.nlm.nih.gov/pubmed/18925047
http://dx.doi.org/10.1155/S1463924695000320
_version_ 1782159403127930880
author Gibb, Stuart W.
Wood, John W.
Fauzi, R.
Mantoura, C.
author_facet Gibb, Stuart W.
Wood, John W.
Fauzi, R.
Mantoura, C.
author_sort Gibb, Stuart W.
collection PubMed
description The automation and improved design and performance of Flow Injection Gas Diffusion-Ion Chromatography (FIGD-IC), a novel technique for the simultaneous analysis of trace ammonia (NH(3)) and methylamines (MAs) in aqueous media, is presented. Automated Flow Injection Gas Diffusion (FIGD) promotes the selective transmembrane diffusion of MAs and NH(3) from aqueous sample under strongly alkaline (pH > 12, NaOH), chelated (EDTA) conditions into a recycled acidic acceptor stream. The acceptor is then injected onto an ion chromatograph where NH(3) and the MAs are fully resolved as their cations and detected conductimetrically. A versatile PC interfaced control unit and data capture unit (DCU) are employed in series to direct the selonoid valve switching sequence, IC operation and collection of data. Automation, together with other modifications improved both linearily (R(2) > 0.99 MAs 0-100 nM, NH(3) 0-1000 nM) and precision (<8%) of FIGD-IC at nanomolar concentrations, compared with the manual procedure. The system was successfully applied to the determination of MAs and NH(3) in seawater and in trapped particulate and gaseous atmospheric samples during an oceanographic research cruise.
format Text
id pubmed-2548102
institution National Center for Biotechnology Information
language English
publishDate 1995
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-25481022008-10-16 Automation of flow injection gas diffusion-ion chromatography for the nanomolar determination of methylamines and ammonia in seawater and atmospheric samples Gibb, Stuart W. Wood, John W. Fauzi, R. Mantoura, C. J Automat Chem Research Article The automation and improved design and performance of Flow Injection Gas Diffusion-Ion Chromatography (FIGD-IC), a novel technique for the simultaneous analysis of trace ammonia (NH(3)) and methylamines (MAs) in aqueous media, is presented. Automated Flow Injection Gas Diffusion (FIGD) promotes the selective transmembrane diffusion of MAs and NH(3) from aqueous sample under strongly alkaline (pH > 12, NaOH), chelated (EDTA) conditions into a recycled acidic acceptor stream. The acceptor is then injected onto an ion chromatograph where NH(3) and the MAs are fully resolved as their cations and detected conductimetrically. A versatile PC interfaced control unit and data capture unit (DCU) are employed in series to direct the selonoid valve switching sequence, IC operation and collection of data. Automation, together with other modifications improved both linearily (R(2) > 0.99 MAs 0-100 nM, NH(3) 0-1000 nM) and precision (<8%) of FIGD-IC at nanomolar concentrations, compared with the manual procedure. The system was successfully applied to the determination of MAs and NH(3) in seawater and in trapped particulate and gaseous atmospheric samples during an oceanographic research cruise. Hindawi Publishing Corporation 1995 /pmc/articles/PMC2548102/ /pubmed/18925047 http://dx.doi.org/10.1155/S1463924695000320 Text en Copyright © 1995 Hindawi Publishing Corporation. http://creativecommons.org/licenses/by/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Gibb, Stuart W.
Wood, John W.
Fauzi, R.
Mantoura, C.
Automation of flow injection gas diffusion-ion chromatography for the nanomolar determination of methylamines and ammonia in seawater and atmospheric samples
title Automation of flow injection gas diffusion-ion chromatography for the nanomolar determination of methylamines and ammonia in seawater and atmospheric samples
title_full Automation of flow injection gas diffusion-ion chromatography for the nanomolar determination of methylamines and ammonia in seawater and atmospheric samples
title_fullStr Automation of flow injection gas diffusion-ion chromatography for the nanomolar determination of methylamines and ammonia in seawater and atmospheric samples
title_full_unstemmed Automation of flow injection gas diffusion-ion chromatography for the nanomolar determination of methylamines and ammonia in seawater and atmospheric samples
title_short Automation of flow injection gas diffusion-ion chromatography for the nanomolar determination of methylamines and ammonia in seawater and atmospheric samples
title_sort automation of flow injection gas diffusion-ion chromatography for the nanomolar determination of methylamines and ammonia in seawater and atmospheric samples
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2548102/
https://www.ncbi.nlm.nih.gov/pubmed/18925047
http://dx.doi.org/10.1155/S1463924695000320
work_keys_str_mv AT gibbstuartw automationofflowinjectiongasdiffusionionchromatographyforthenanomolardeterminationofmethylaminesandammoniainseawaterandatmosphericsamples
AT woodjohnw automationofflowinjectiongasdiffusionionchromatographyforthenanomolardeterminationofmethylaminesandammoniainseawaterandatmosphericsamples
AT fauzir automationofflowinjectiongasdiffusionionchromatographyforthenanomolardeterminationofmethylaminesandammoniainseawaterandatmosphericsamples
AT mantourac automationofflowinjectiongasdiffusionionchromatographyforthenanomolardeterminationofmethylaminesandammoniainseawaterandatmosphericsamples