Cargando…

An automated system for liquid-liquid extraction in monosegmented flow analysis

An automated system to perform liquid-liquid extraction in monosegmented flow analysis is described. The system is controlled by a microcomputer that can track the localization of the aqueous monosegmented sample in the manifold. Optical switches are employed to sense the gas-liquid interface of the...

Descripción completa

Detalles Bibliográficos
Autores principales: Facchin, Ileana, Rohwedder, Jarbas J. R., Pasquini, Celio
Formato: Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 1997
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2548117/
https://www.ncbi.nlm.nih.gov/pubmed/18924792
http://dx.doi.org/10.1155/S1463924697000059
_version_ 1782159406686797824
author Facchin, Ileana
Rohwedder, Jarbas J. R.
Pasquini, Celio
author_facet Facchin, Ileana
Rohwedder, Jarbas J. R.
Pasquini, Celio
author_sort Facchin, Ileana
collection PubMed
description An automated system to perform liquid-liquid extraction in monosegmented flow analysis is described. The system is controlled by a microcomputer that can track the localization of the aqueous monosegmented sample in the manifold. Optical switches are employed to sense the gas-liquid interface of the air bubbles that define the monosegment. The logical level changes, generated by the switches, are flagged by the computer through a home-made interface that also contains the analogue-to-digital converter for signal acquisition. The sequence of operations, necessary for a single extraction or for concentration of the analyte in the organic phase, is triggered by these logical transitions. The system was evaluated for extraction of Cd(II), Cu(II) and Zn(II) and concentration of Cd(II) from aqueous solutions at pH 9.9 (NH(3)/NH(4)Cl buffer) into chloroform containing PAN (1-(2-pyridylazo)-2-naphthol) . The results show a mean repeatability of 3% (rsd) for a 2.0 mg l(-1) Cd(II) solution and a linear increase of the concentration factor for a 0.5mg l(-1) Cd(II) solution observed for up to nine extraction cycles.
format Text
id pubmed-2548117
institution National Center for Biotechnology Information
language English
publishDate 1997
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-25481172008-10-16 An automated system for liquid-liquid extraction in monosegmented flow analysis Facchin, Ileana Rohwedder, Jarbas J. R. Pasquini, Celio J Automat Chem Research Article An automated system to perform liquid-liquid extraction in monosegmented flow analysis is described. The system is controlled by a microcomputer that can track the localization of the aqueous monosegmented sample in the manifold. Optical switches are employed to sense the gas-liquid interface of the air bubbles that define the monosegment. The logical level changes, generated by the switches, are flagged by the computer through a home-made interface that also contains the analogue-to-digital converter for signal acquisition. The sequence of operations, necessary for a single extraction or for concentration of the analyte in the organic phase, is triggered by these logical transitions. The system was evaluated for extraction of Cd(II), Cu(II) and Zn(II) and concentration of Cd(II) from aqueous solutions at pH 9.9 (NH(3)/NH(4)Cl buffer) into chloroform containing PAN (1-(2-pyridylazo)-2-naphthol) . The results show a mean repeatability of 3% (rsd) for a 2.0 mg l(-1) Cd(II) solution and a linear increase of the concentration factor for a 0.5mg l(-1) Cd(II) solution observed for up to nine extraction cycles. Hindawi Publishing Corporation 1997 /pmc/articles/PMC2548117/ /pubmed/18924792 http://dx.doi.org/10.1155/S1463924697000059 Text en Copyright © 1997 Hindawi Publishing Corporation. http://creativecommons.org/licenses/by/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Facchin, Ileana
Rohwedder, Jarbas J. R.
Pasquini, Celio
An automated system for liquid-liquid extraction in monosegmented flow analysis
title An automated system for liquid-liquid extraction in monosegmented flow analysis
title_full An automated system for liquid-liquid extraction in monosegmented flow analysis
title_fullStr An automated system for liquid-liquid extraction in monosegmented flow analysis
title_full_unstemmed An automated system for liquid-liquid extraction in monosegmented flow analysis
title_short An automated system for liquid-liquid extraction in monosegmented flow analysis
title_sort automated system for liquid-liquid extraction in monosegmented flow analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2548117/
https://www.ncbi.nlm.nih.gov/pubmed/18924792
http://dx.doi.org/10.1155/S1463924697000059
work_keys_str_mv AT facchinileana anautomatedsystemforliquidliquidextractioninmonosegmentedflowanalysis
AT rohwedderjarbasjr anautomatedsystemforliquidliquidextractioninmonosegmentedflowanalysis
AT pasquinicelio anautomatedsystemforliquidliquidextractioninmonosegmentedflowanalysis
AT facchinileana automatedsystemforliquidliquidextractioninmonosegmentedflowanalysis
AT rohwedderjarbasjr automatedsystemforliquidliquidextractioninmonosegmentedflowanalysis
AT pasquinicelio automatedsystemforliquidliquidextractioninmonosegmentedflowanalysis