First basic performance evaluation of the XE-2100 haematology analyser

The newly developed XE-2100 haematology analyser can provide complete blood counts, leukocyte differentials, perform reticulocyte analysis, and obtain quantitative data on nucleated red blood cells (NRBCs). In this study, we evaluated the basic performance of this instrument using routinely obtained...

Descripción completa

Detalles Bibliográficos
Autores principales: Tsuda, Izumi, Hino, Masayuki, Takubo, Takayuki, Katagami, Tomoko, Kubota, Hiroshi, Kawai, Seiki, Tatsumi, N.
Formato: Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 1999
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2548250/
https://www.ncbi.nlm.nih.gov/pubmed/18924849
http://dx.doi.org/10.1155/S1463924699000152
_version_ 1782159422490935296
author Tsuda, Izumi
Hino, Masayuki
Takubo, Takayuki
Katagami, Tomoko
Kubota, Hiroshi
Kawai, Seiki
Tatsumi, N.
author_facet Tsuda, Izumi
Hino, Masayuki
Takubo, Takayuki
Katagami, Tomoko
Kubota, Hiroshi
Kawai, Seiki
Tatsumi, N.
author_sort Tsuda, Izumi
collection PubMed
description The newly developed XE-2100 haematology analyser can provide complete blood counts, leukocyte differentials, perform reticulocyte analysis, and obtain quantitative data on nucleated red blood cells (NRBCs). In this study, we evaluated the basic performance of this instrument using routinely obtained blood specimens treated with ethylenediaminetetraacetic acid-2k. Reproducibility, carryover, stability during storage at 4°C and room temperature, and accuracy were evaluated. In this evaluation, reproducibility was good and little carryover was found. Accurate measurements were possible for up to 48h of storage. A good correlation between findings with the XE-2100 and SE-9000 haematology analysers was found for complete blood count on 210 samples tested. The leukocyte differential obtained with the XE-2100 correlated well with eye counts and with the results obtained with the SE-9000 automated haematology analyser, with r values over 0.9 for the percentages of neutrophils, lymphocytes and eosinophils. The precision and accuracy of VRBC and reticulocyte counts by the XE-2100 were satisfactory. We used the XE-2100 to obtain differential counts for bone marrow aspirates, and good correlations with manual differentials were obtained for total nucleated cell count, percentage of myeloid cells and percentage of erythroid cells. The performance of the XE-2100 was excellent, and this instrument should be able to provide reliable data to clinical laboratories.
format Text
id pubmed-2548250
institution National Center for Biotechnology Information
language English
publishDate 1999
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-25482502008-10-16 First basic performance evaluation of the XE-2100 haematology analyser Tsuda, Izumi Hino, Masayuki Takubo, Takayuki Katagami, Tomoko Kubota, Hiroshi Kawai, Seiki Tatsumi, N. J Autom Methods Manag Chem Research Article The newly developed XE-2100 haematology analyser can provide complete blood counts, leukocyte differentials, perform reticulocyte analysis, and obtain quantitative data on nucleated red blood cells (NRBCs). In this study, we evaluated the basic performance of this instrument using routinely obtained blood specimens treated with ethylenediaminetetraacetic acid-2k. Reproducibility, carryover, stability during storage at 4°C and room temperature, and accuracy were evaluated. In this evaluation, reproducibility was good and little carryover was found. Accurate measurements were possible for up to 48h of storage. A good correlation between findings with the XE-2100 and SE-9000 haematology analysers was found for complete blood count on 210 samples tested. The leukocyte differential obtained with the XE-2100 correlated well with eye counts and with the results obtained with the SE-9000 automated haematology analyser, with r values over 0.9 for the percentages of neutrophils, lymphocytes and eosinophils. The precision and accuracy of VRBC and reticulocyte counts by the XE-2100 were satisfactory. We used the XE-2100 to obtain differential counts for bone marrow aspirates, and good correlations with manual differentials were obtained for total nucleated cell count, percentage of myeloid cells and percentage of erythroid cells. The performance of the XE-2100 was excellent, and this instrument should be able to provide reliable data to clinical laboratories. Hindawi Publishing Corporation 1999 /pmc/articles/PMC2548250/ /pubmed/18924849 http://dx.doi.org/10.1155/S1463924699000152 Text en Copyright © 1999 Hindawi Publishing Corporation. http://creativecommons.org/licenses/by/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Tsuda, Izumi
Hino, Masayuki
Takubo, Takayuki
Katagami, Tomoko
Kubota, Hiroshi
Kawai, Seiki
Tatsumi, N.
First basic performance evaluation of the XE-2100 haematology analyser
title First basic performance evaluation of the XE-2100 haematology analyser
title_full First basic performance evaluation of the XE-2100 haematology analyser
title_fullStr First basic performance evaluation of the XE-2100 haematology analyser
title_full_unstemmed First basic performance evaluation of the XE-2100 haematology analyser
title_short First basic performance evaluation of the XE-2100 haematology analyser
title_sort first basic performance evaluation of the xe-2100 haematology analyser
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2548250/
https://www.ncbi.nlm.nih.gov/pubmed/18924849
http://dx.doi.org/10.1155/S1463924699000152
work_keys_str_mv AT tsudaizumi firstbasicperformanceevaluationofthexe2100haematologyanalyser
AT hinomasayuki firstbasicperformanceevaluationofthexe2100haematologyanalyser
AT takubotakayuki firstbasicperformanceevaluationofthexe2100haematologyanalyser
AT katagamitomoko firstbasicperformanceevaluationofthexe2100haematologyanalyser
AT kubotahiroshi firstbasicperformanceevaluationofthexe2100haematologyanalyser
AT kawaiseiki firstbasicperformanceevaluationofthexe2100haematologyanalyser
AT tatsumin firstbasicperformanceevaluationofthexe2100haematologyanalyser