Development of a method for the determination of ultra-trace level mercury in adipose tissue by cold vapour atomic fluorescence spectrometry
A method for the determination of total mercury in rat adipose tissue by cold vapour atomic fluorescence spectrometry (CVAFS) has been developed. Adipose samples were initially subjected to a lyophilization procedure in order to facilitate the homogenization and accurate weighing of small tissue ali...
Autores principales: | , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2000
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2548265/ https://www.ncbi.nlm.nih.gov/pubmed/18924864 http://dx.doi.org/10.1155/S1463924600000146 |
_version_ | 1782159425959624704 |
---|---|
author | Levine, Keith E. Fernando, Reshan A. Lang, M. Essader, Amal Handy, Robert W. Collins, Bradley J. |
author_facet | Levine, Keith E. Fernando, Reshan A. Lang, M. Essader, Amal Handy, Robert W. Collins, Bradley J. |
author_sort | Levine, Keith E. |
collection | PubMed |
description | A method for the determination of total mercury in rat adipose tissue by cold vapour atomic fluorescence spectrometry (CVAFS) has been developed. Adipose samples were initially subjected to a lyophilization procedure in order to facilitate the homogenization and accurate weighing of small tissue aliquots (~50 mg). A closed vessel microwave digestion procedure using a mixture of sulphuric and nitric acids was used to liberate mercury from the adipose matrix. All mercury species were quantitatively oxidized to Hg(II) by a potassium bromate/bromide oxidation, then reduced to Hg(0) vapour by stannous chloride prior to fluorescence detection. The CVAFS exhibited a linear range of 10 pg Hg/ml to 120 pg Hg/ml. The method detection limit in solution was 2 pg Hg/ml, or 1 ng Hg/g adipose tissue, based on a nominal 50 mg sample and a final volume of 25 ml. A reference material from the National Research Council of Canada (DOLT-2, trace metals in dogfish liver) was prepared in quadruplicate in order to assess the accuracy and precision of the method. Mercury in this material was recovered at 2.22 ± 0.08 μ g/g, which is 104% of the certified level (2.14 ± 0.10 μ g/g). |
format | Text |
id | pubmed-2548265 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2000 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-25482652008-10-16 Development of a method for the determination of ultra-trace level mercury in adipose tissue by cold vapour atomic fluorescence spectrometry Levine, Keith E. Fernando, Reshan A. Lang, M. Essader, Amal Handy, Robert W. Collins, Bradley J. J Autom Methods Manag Chem Research Article A method for the determination of total mercury in rat adipose tissue by cold vapour atomic fluorescence spectrometry (CVAFS) has been developed. Adipose samples were initially subjected to a lyophilization procedure in order to facilitate the homogenization and accurate weighing of small tissue aliquots (~50 mg). A closed vessel microwave digestion procedure using a mixture of sulphuric and nitric acids was used to liberate mercury from the adipose matrix. All mercury species were quantitatively oxidized to Hg(II) by a potassium bromate/bromide oxidation, then reduced to Hg(0) vapour by stannous chloride prior to fluorescence detection. The CVAFS exhibited a linear range of 10 pg Hg/ml to 120 pg Hg/ml. The method detection limit in solution was 2 pg Hg/ml, or 1 ng Hg/g adipose tissue, based on a nominal 50 mg sample and a final volume of 25 ml. A reference material from the National Research Council of Canada (DOLT-2, trace metals in dogfish liver) was prepared in quadruplicate in order to assess the accuracy and precision of the method. Mercury in this material was recovered at 2.22 ± 0.08 μ g/g, which is 104% of the certified level (2.14 ± 0.10 μ g/g). Hindawi Publishing Corporation 2000 /pmc/articles/PMC2548265/ /pubmed/18924864 http://dx.doi.org/10.1155/S1463924600000146 Text en Copyright © 2000 Hindawi Publishing Corporation. http://creativecommons.org/licenses/by/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Levine, Keith E. Fernando, Reshan A. Lang, M. Essader, Amal Handy, Robert W. Collins, Bradley J. Development of a method for the determination of ultra-trace level mercury in adipose tissue by cold vapour atomic fluorescence spectrometry |
title | Development of a method for the determination of ultra-trace level mercury in adipose tissue by cold vapour atomic fluorescence spectrometry |
title_full | Development of a method for the determination of ultra-trace level mercury in adipose tissue by cold vapour atomic fluorescence spectrometry |
title_fullStr | Development of a method for the determination of ultra-trace level mercury in adipose tissue by cold vapour atomic fluorescence spectrometry |
title_full_unstemmed | Development of a method for the determination of ultra-trace level mercury in adipose tissue by cold vapour atomic fluorescence spectrometry |
title_short | Development of a method for the determination of ultra-trace level mercury in adipose tissue by cold vapour atomic fluorescence spectrometry |
title_sort | development of a method for the determination of ultra-trace level mercury in adipose tissue by cold vapour atomic fluorescence spectrometry |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2548265/ https://www.ncbi.nlm.nih.gov/pubmed/18924864 http://dx.doi.org/10.1155/S1463924600000146 |
work_keys_str_mv | AT levinekeithe developmentofamethodforthedeterminationofultratracelevelmercuryinadiposetissuebycoldvapouratomicfluorescencespectrometry AT fernandoreshana developmentofamethodforthedeterminationofultratracelevelmercuryinadiposetissuebycoldvapouratomicfluorescencespectrometry AT langm developmentofamethodforthedeterminationofultratracelevelmercuryinadiposetissuebycoldvapouratomicfluorescencespectrometry AT essaderamal developmentofamethodforthedeterminationofultratracelevelmercuryinadiposetissuebycoldvapouratomicfluorescencespectrometry AT handyrobertw developmentofamethodforthedeterminationofultratracelevelmercuryinadiposetissuebycoldvapouratomicfluorescencespectrometry AT collinsbradleyj developmentofamethodforthedeterminationofultratracelevelmercuryinadiposetissuebycoldvapouratomicfluorescencespectrometry |