Development of a method for the determination of ultra-trace level mercury in adipose tissue by cold vapour atomic fluorescence spectrometry

A method for the determination of total mercury in rat adipose tissue by cold vapour atomic fluorescence spectrometry (CVAFS) has been developed. Adipose samples were initially subjected to a lyophilization procedure in order to facilitate the homogenization and accurate weighing of small tissue ali...

Descripción completa

Detalles Bibliográficos
Autores principales: Levine, Keith E., Fernando, Reshan A., Lang, M., Essader, Amal, Handy, Robert W., Collins, Bradley J.
Formato: Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2000
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2548265/
https://www.ncbi.nlm.nih.gov/pubmed/18924864
http://dx.doi.org/10.1155/S1463924600000146
_version_ 1782159425959624704
author Levine, Keith E.
Fernando, Reshan A.
Lang, M.
Essader, Amal
Handy, Robert W.
Collins, Bradley J.
author_facet Levine, Keith E.
Fernando, Reshan A.
Lang, M.
Essader, Amal
Handy, Robert W.
Collins, Bradley J.
author_sort Levine, Keith E.
collection PubMed
description A method for the determination of total mercury in rat adipose tissue by cold vapour atomic fluorescence spectrometry (CVAFS) has been developed. Adipose samples were initially subjected to a lyophilization procedure in order to facilitate the homogenization and accurate weighing of small tissue aliquots (~50 mg). A closed vessel microwave digestion procedure using a mixture of sulphuric and nitric acids was used to liberate mercury from the adipose matrix. All mercury species were quantitatively oxidized to Hg(II) by a potassium bromate/bromide oxidation, then reduced to Hg(0) vapour by stannous chloride prior to fluorescence detection. The CVAFS exhibited a linear range of 10 pg Hg/ml to 120 pg Hg/ml. The method detection limit in solution was 2 pg Hg/ml, or 1 ng Hg/g adipose tissue, based on a nominal 50 mg sample and a final volume of 25 ml. A reference material from the National Research Council of Canada (DOLT-2, trace metals in dogfish liver) was prepared in quadruplicate in order to assess the accuracy and precision of the method. Mercury in this material was recovered at 2.22 ± 0.08 μ g/g, which is 104% of the certified level (2.14 ± 0.10 μ g/g).
format Text
id pubmed-2548265
institution National Center for Biotechnology Information
language English
publishDate 2000
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-25482652008-10-16 Development of a method for the determination of ultra-trace level mercury in adipose tissue by cold vapour atomic fluorescence spectrometry Levine, Keith E. Fernando, Reshan A. Lang, M. Essader, Amal Handy, Robert W. Collins, Bradley J. J Autom Methods Manag Chem Research Article A method for the determination of total mercury in rat adipose tissue by cold vapour atomic fluorescence spectrometry (CVAFS) has been developed. Adipose samples were initially subjected to a lyophilization procedure in order to facilitate the homogenization and accurate weighing of small tissue aliquots (~50 mg). A closed vessel microwave digestion procedure using a mixture of sulphuric and nitric acids was used to liberate mercury from the adipose matrix. All mercury species were quantitatively oxidized to Hg(II) by a potassium bromate/bromide oxidation, then reduced to Hg(0) vapour by stannous chloride prior to fluorescence detection. The CVAFS exhibited a linear range of 10 pg Hg/ml to 120 pg Hg/ml. The method detection limit in solution was 2 pg Hg/ml, or 1 ng Hg/g adipose tissue, based on a nominal 50 mg sample and a final volume of 25 ml. A reference material from the National Research Council of Canada (DOLT-2, trace metals in dogfish liver) was prepared in quadruplicate in order to assess the accuracy and precision of the method. Mercury in this material was recovered at 2.22 ± 0.08 μ g/g, which is 104% of the certified level (2.14 ± 0.10 μ g/g). Hindawi Publishing Corporation 2000 /pmc/articles/PMC2548265/ /pubmed/18924864 http://dx.doi.org/10.1155/S1463924600000146 Text en Copyright © 2000 Hindawi Publishing Corporation. http://creativecommons.org/licenses/by/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Levine, Keith E.
Fernando, Reshan A.
Lang, M.
Essader, Amal
Handy, Robert W.
Collins, Bradley J.
Development of a method for the determination of ultra-trace level mercury in adipose tissue by cold vapour atomic fluorescence spectrometry
title Development of a method for the determination of ultra-trace level mercury in adipose tissue by cold vapour atomic fluorescence spectrometry
title_full Development of a method for the determination of ultra-trace level mercury in adipose tissue by cold vapour atomic fluorescence spectrometry
title_fullStr Development of a method for the determination of ultra-trace level mercury in adipose tissue by cold vapour atomic fluorescence spectrometry
title_full_unstemmed Development of a method for the determination of ultra-trace level mercury in adipose tissue by cold vapour atomic fluorescence spectrometry
title_short Development of a method for the determination of ultra-trace level mercury in adipose tissue by cold vapour atomic fluorescence spectrometry
title_sort development of a method for the determination of ultra-trace level mercury in adipose tissue by cold vapour atomic fluorescence spectrometry
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2548265/
https://www.ncbi.nlm.nih.gov/pubmed/18924864
http://dx.doi.org/10.1155/S1463924600000146
work_keys_str_mv AT levinekeithe developmentofamethodforthedeterminationofultratracelevelmercuryinadiposetissuebycoldvapouratomicfluorescencespectrometry
AT fernandoreshana developmentofamethodforthedeterminationofultratracelevelmercuryinadiposetissuebycoldvapouratomicfluorescencespectrometry
AT langm developmentofamethodforthedeterminationofultratracelevelmercuryinadiposetissuebycoldvapouratomicfluorescencespectrometry
AT essaderamal developmentofamethodforthedeterminationofultratracelevelmercuryinadiposetissuebycoldvapouratomicfluorescencespectrometry
AT handyrobertw developmentofamethodforthedeterminationofultratracelevelmercuryinadiposetissuebycoldvapouratomicfluorescencespectrometry
AT collinsbradleyj developmentofamethodforthedeterminationofultratracelevelmercuryinadiposetissuebycoldvapouratomicfluorescencespectrometry