Cargando…

Proposed fibrinogen standard material with purified fibrinogen for plasma fibrinogen measurement on coagulation analyser

A commercially available fibrinogen standard calibrated by a World Health Organization (WHO) reference material is widely used in Japan, and most clinical laboratories use the Clauss method for plasma fibrinogen measurement. However, a current issue in fibrinogen measurement is poor laboratory-to-la...

Descripción completa

Detalles Bibliográficos
Autores principales: Okuda, Masahiro, Uemura, Yahiro, Tatsumi, Noriyuki, Honda, Susumu
Formato: Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2003
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2548388/
https://www.ncbi.nlm.nih.gov/pubmed/18924618
http://dx.doi.org/10.1155/S146392460300018X
_version_ 1782159435031904256
author Okuda, Masahiro
Uemura, Yahiro
Tatsumi, Noriyuki
Honda, Susumu
author_facet Okuda, Masahiro
Uemura, Yahiro
Tatsumi, Noriyuki
Honda, Susumu
author_sort Okuda, Masahiro
collection PubMed
description A commercially available fibrinogen standard calibrated by a World Health Organization (WHO) reference material is widely used in Japan, and most clinical laboratories use the Clauss method for plasma fibrinogen measurement. However, a current issue in fibrinogen measurement is poor laboratory-to-laboratory variability. To improve the reliability of fibrinogen values and thereby solve the poor precision and accuracy of plasma fibrinogen testing, the present paper develops a simple and large preparation procedure for a suitable fibrinogen standard and quality control material and evaluates their basic performance. With a new procedure getting high purified fibrinogen by glycine precipitation, the calibrator determined by both the Clauss and Jacobson methods produced a fibrinogen concentration of 2.20 g l(−1). The total precision of the calibrator was excellent (coefficient of variation 1.4-2.1%) in comparison with current plasma fibrinogen materials from the WHO (#98/612) and with a commercial standard (CV 1.9-3.9%). The within-run precision of the calibrator on the coagulation analysers was 1.7-2.8%. Within-analyser variability among the five instruments had good consistency (mean 2.20 ± 0.022 g l(−1); CV 1.0%). The degradation study of the calibrator suggested that storage at 9(°)C for two years was as predicted. In conclusion, the results show that the calibrator prepared herein can be useful as a candidate Japanese fibrinogen standard and is applicable to automated and semi-automated coagulation analysers. Additionally, it is expected that it will be widely used in Japan by diagnostic manufacturers and clinical laboratories as a recommended secondary standard to estimate a fibrinogen value according to the WHO primary standard.
format Text
id pubmed-2548388
institution National Center for Biotechnology Information
language English
publishDate 2003
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-25483882008-10-16 Proposed fibrinogen standard material with purified fibrinogen for plasma fibrinogen measurement on coagulation analyser Okuda, Masahiro Uemura, Yahiro Tatsumi, Noriyuki Honda, Susumu J Autom Methods Manag Chem Research Article A commercially available fibrinogen standard calibrated by a World Health Organization (WHO) reference material is widely used in Japan, and most clinical laboratories use the Clauss method for plasma fibrinogen measurement. However, a current issue in fibrinogen measurement is poor laboratory-to-laboratory variability. To improve the reliability of fibrinogen values and thereby solve the poor precision and accuracy of plasma fibrinogen testing, the present paper develops a simple and large preparation procedure for a suitable fibrinogen standard and quality control material and evaluates their basic performance. With a new procedure getting high purified fibrinogen by glycine precipitation, the calibrator determined by both the Clauss and Jacobson methods produced a fibrinogen concentration of 2.20 g l(−1). The total precision of the calibrator was excellent (coefficient of variation 1.4-2.1%) in comparison with current plasma fibrinogen materials from the WHO (#98/612) and with a commercial standard (CV 1.9-3.9%). The within-run precision of the calibrator on the coagulation analysers was 1.7-2.8%. Within-analyser variability among the five instruments had good consistency (mean 2.20 ± 0.022 g l(−1); CV 1.0%). The degradation study of the calibrator suggested that storage at 9(°)C for two years was as predicted. In conclusion, the results show that the calibrator prepared herein can be useful as a candidate Japanese fibrinogen standard and is applicable to automated and semi-automated coagulation analysers. Additionally, it is expected that it will be widely used in Japan by diagnostic manufacturers and clinical laboratories as a recommended secondary standard to estimate a fibrinogen value according to the WHO primary standard. Hindawi Publishing Corporation 2003 /pmc/articles/PMC2548388/ /pubmed/18924618 http://dx.doi.org/10.1155/S146392460300018X Text en Copyright © 2003 Hindawi Publishing Corporation. http://creativecommons.org/licenses/by/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Okuda, Masahiro
Uemura, Yahiro
Tatsumi, Noriyuki
Honda, Susumu
Proposed fibrinogen standard material with purified fibrinogen for plasma fibrinogen measurement on coagulation analyser
title Proposed fibrinogen standard material with purified fibrinogen for plasma fibrinogen measurement on coagulation analyser
title_full Proposed fibrinogen standard material with purified fibrinogen for plasma fibrinogen measurement on coagulation analyser
title_fullStr Proposed fibrinogen standard material with purified fibrinogen for plasma fibrinogen measurement on coagulation analyser
title_full_unstemmed Proposed fibrinogen standard material with purified fibrinogen for plasma fibrinogen measurement on coagulation analyser
title_short Proposed fibrinogen standard material with purified fibrinogen for plasma fibrinogen measurement on coagulation analyser
title_sort proposed fibrinogen standard material with purified fibrinogen for plasma fibrinogen measurement on coagulation analyser
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2548388/
https://www.ncbi.nlm.nih.gov/pubmed/18924618
http://dx.doi.org/10.1155/S146392460300018X
work_keys_str_mv AT okudamasahiro proposedfibrinogenstandardmaterialwithpurifiedfibrinogenforplasmafibrinogenmeasurementoncoagulationanalyser
AT uemurayahiro proposedfibrinogenstandardmaterialwithpurifiedfibrinogenforplasmafibrinogenmeasurementoncoagulationanalyser
AT tatsuminoriyuki proposedfibrinogenstandardmaterialwithpurifiedfibrinogenforplasmafibrinogenmeasurementoncoagulationanalyser
AT hondasusumu proposedfibrinogenstandardmaterialwithpurifiedfibrinogenforplasmafibrinogenmeasurementoncoagulationanalyser