Design of an Automated Flow Injection-Chemiluminescence Instrument Incorporating a Miniature Photomultiplier Tube for Monitoring Picomolar Concentrations of Iron in Seawater

A flow-injection (FI)-based instrument under LabVIEW control for monitoring iron in marine waters is described. The instrument incorporates a miniature, low-power photomultiplier tube (PMT), and a number of microelectric and solenoid actuated valves and peristaltic pumps. The software allows full co...

Descripción completa

Detalles Bibliográficos
Autores principales: Bowie, Andrew R., Achterberg, Eric P., Ussher, Simon, Worsfold, Paul J.
Formato: Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2005
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2548398/
https://www.ncbi.nlm.nih.gov/pubmed/18924627
http://dx.doi.org/10.1155/JAMMC.2005.37
_version_ 1782159437337722880
author Bowie, Andrew R.
Achterberg, Eric P.
Ussher, Simon
Worsfold, Paul J.
author_facet Bowie, Andrew R.
Achterberg, Eric P.
Ussher, Simon
Worsfold, Paul J.
author_sort Bowie, Andrew R.
collection PubMed
description A flow-injection (FI)-based instrument under LabVIEW control for monitoring iron in marine waters is described. The instrument incorporates a miniature, low-power photomultiplier tube (PMT), and a number of microelectric and solenoid actuated valves and peristaltic pumps. The software allows full control of all flow injection components and processing of the data from the PMT. The optimised system is capable of 20 injections per hour, including preconcentration and wash steps. The detection limit (3 sd of the blank) is 21 pM at sea and the linear range is 21–2000 pM with a 60-second sample load time. Typical precision between replicate FI peaks is 5.9 ± 3.2 % (n =4) over the linear range.
format Text
id pubmed-2548398
institution National Center for Biotechnology Information
language English
publishDate 2005
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-25483982008-10-16 Design of an Automated Flow Injection-Chemiluminescence Instrument Incorporating a Miniature Photomultiplier Tube for Monitoring Picomolar Concentrations of Iron in Seawater Bowie, Andrew R. Achterberg, Eric P. Ussher, Simon Worsfold, Paul J. J Autom Methods Manag Chem Research Article A flow-injection (FI)-based instrument under LabVIEW control for monitoring iron in marine waters is described. The instrument incorporates a miniature, low-power photomultiplier tube (PMT), and a number of microelectric and solenoid actuated valves and peristaltic pumps. The software allows full control of all flow injection components and processing of the data from the PMT. The optimised system is capable of 20 injections per hour, including preconcentration and wash steps. The detection limit (3 sd of the blank) is 21 pM at sea and the linear range is 21–2000 pM with a 60-second sample load time. Typical precision between replicate FI peaks is 5.9 ± 3.2 % (n =4) over the linear range. Hindawi Publishing Corporation 2005 /pmc/articles/PMC2548398/ /pubmed/18924627 http://dx.doi.org/10.1155/JAMMC.2005.37 Text en Copyright © 2005 Hindawi Publishing Corporation. http://creativecommons.org/licenses/by/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Bowie, Andrew R.
Achterberg, Eric P.
Ussher, Simon
Worsfold, Paul J.
Design of an Automated Flow Injection-Chemiluminescence Instrument Incorporating a Miniature Photomultiplier Tube for Monitoring Picomolar Concentrations of Iron in Seawater
title Design of an Automated Flow Injection-Chemiluminescence Instrument Incorporating a Miniature Photomultiplier Tube for Monitoring Picomolar Concentrations of Iron in Seawater
title_full Design of an Automated Flow Injection-Chemiluminescence Instrument Incorporating a Miniature Photomultiplier Tube for Monitoring Picomolar Concentrations of Iron in Seawater
title_fullStr Design of an Automated Flow Injection-Chemiluminescence Instrument Incorporating a Miniature Photomultiplier Tube for Monitoring Picomolar Concentrations of Iron in Seawater
title_full_unstemmed Design of an Automated Flow Injection-Chemiluminescence Instrument Incorporating a Miniature Photomultiplier Tube for Monitoring Picomolar Concentrations of Iron in Seawater
title_short Design of an Automated Flow Injection-Chemiluminescence Instrument Incorporating a Miniature Photomultiplier Tube for Monitoring Picomolar Concentrations of Iron in Seawater
title_sort design of an automated flow injection-chemiluminescence instrument incorporating a miniature photomultiplier tube for monitoring picomolar concentrations of iron in seawater
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2548398/
https://www.ncbi.nlm.nih.gov/pubmed/18924627
http://dx.doi.org/10.1155/JAMMC.2005.37
work_keys_str_mv AT bowieandrewr designofanautomatedflowinjectionchemiluminescenceinstrumentincorporatingaminiaturephotomultipliertubeformonitoringpicomolarconcentrationsofironinseawater
AT achterbergericp designofanautomatedflowinjectionchemiluminescenceinstrumentincorporatingaminiaturephotomultipliertubeformonitoringpicomolarconcentrationsofironinseawater
AT usshersimon designofanautomatedflowinjectionchemiluminescenceinstrumentincorporatingaminiaturephotomultipliertubeformonitoringpicomolarconcentrationsofironinseawater
AT worsfoldpaulj designofanautomatedflowinjectionchemiluminescenceinstrumentincorporatingaminiaturephotomultipliertubeformonitoringpicomolarconcentrationsofironinseawater