Cargando…

Automated analyser for monitoring trace amounts of volatile chloro-organic compounds in recirculated industrial water

An automated analyser of volatile chloro-organic compounds in water was constructed and tested using standard mixtures of dichloromethane and dichloroethane. It was based on continuous, countercurrent gas stripping of the liquid sample followed by periodic trapping of the analytes on two traps alter...

Descripción completa

Detalles Bibliográficos
Autores principales: Janicki, Wacław, Chrzanowski, Wojciech, Wasik, Andrzej, Przyk, Elżbieta, Namieśnik, Jacek
Formato: Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2002
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2562959/
https://www.ncbi.nlm.nih.gov/pubmed/18924724
http://dx.doi.org/10.1155/S1463924602000020
_version_ 1782159772126019584
author Janicki, Wacław
Chrzanowski, Wojciech
Wasik, Andrzej
Przyk, Elżbieta
Namieśnik, Jacek
author_facet Janicki, Wacław
Chrzanowski, Wojciech
Wasik, Andrzej
Przyk, Elżbieta
Namieśnik, Jacek
author_sort Janicki, Wacław
collection PubMed
description An automated analyser of volatile chloro-organic compounds in water was constructed and tested using standard mixtures of dichloromethane and dichloroethane. It was based on continuous, countercurrent gas stripping of the liquid sample followed by periodic trapping of the analytes on two traps alternately connected to the bubbler outlet, and thermal desorption. When one trap performed adsorption, the other underwent desorption and cooling. Analytes were detected by an ECD detector. Integration, calibration, calculations and overall operating cycle control was performed by a microcomputer. The instrument guarantees a 0.02 ppm Cl (w/w) detection limit, a 0—2 ppm detection range and 2 months of autonomous operation. Results are reported every 13 min.
format Text
id pubmed-2562959
institution National Center for Biotechnology Information
language English
publishDate 2002
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-25629592008-10-16 Automated analyser for monitoring trace amounts of volatile chloro-organic compounds in recirculated industrial water Janicki, Wacław Chrzanowski, Wojciech Wasik, Andrzej Przyk, Elżbieta Namieśnik, Jacek J Autom Methods Manag Chem Research Article An automated analyser of volatile chloro-organic compounds in water was constructed and tested using standard mixtures of dichloromethane and dichloroethane. It was based on continuous, countercurrent gas stripping of the liquid sample followed by periodic trapping of the analytes on two traps alternately connected to the bubbler outlet, and thermal desorption. When one trap performed adsorption, the other underwent desorption and cooling. Analytes were detected by an ECD detector. Integration, calibration, calculations and overall operating cycle control was performed by a microcomputer. The instrument guarantees a 0.02 ppm Cl (w/w) detection limit, a 0—2 ppm detection range and 2 months of autonomous operation. Results are reported every 13 min. Hindawi Publishing Corporation 2002 /pmc/articles/PMC2562959/ /pubmed/18924724 http://dx.doi.org/10.1155/S1463924602000020 Text en Copyright © 2002 Hindawi Publishing Corporation. http://creativecommons.org/licenses/by/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Janicki, Wacław
Chrzanowski, Wojciech
Wasik, Andrzej
Przyk, Elżbieta
Namieśnik, Jacek
Automated analyser for monitoring trace amounts of volatile chloro-organic compounds in recirculated industrial water
title Automated analyser for monitoring trace amounts of volatile chloro-organic compounds in recirculated industrial water
title_full Automated analyser for monitoring trace amounts of volatile chloro-organic compounds in recirculated industrial water
title_fullStr Automated analyser for monitoring trace amounts of volatile chloro-organic compounds in recirculated industrial water
title_full_unstemmed Automated analyser for monitoring trace amounts of volatile chloro-organic compounds in recirculated industrial water
title_short Automated analyser for monitoring trace amounts of volatile chloro-organic compounds in recirculated industrial water
title_sort automated analyser for monitoring trace amounts of volatile chloro-organic compounds in recirculated industrial water
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2562959/
https://www.ncbi.nlm.nih.gov/pubmed/18924724
http://dx.doi.org/10.1155/S1463924602000020
work_keys_str_mv AT janickiwacław automatedanalyserformonitoringtraceamountsofvolatilechloroorganiccompoundsinrecirculatedindustrialwater
AT chrzanowskiwojciech automatedanalyserformonitoringtraceamountsofvolatilechloroorganiccompoundsinrecirculatedindustrialwater
AT wasikandrzej automatedanalyserformonitoringtraceamountsofvolatilechloroorganiccompoundsinrecirculatedindustrialwater
AT przykelzbieta automatedanalyserformonitoringtraceamountsofvolatilechloroorganiccompoundsinrecirculatedindustrialwater
AT namiesnikjacek automatedanalyserformonitoringtraceamountsofvolatilechloroorganiccompoundsinrecirculatedindustrialwater