Cargando…

Tadpole system as new lumbar spinal instrumentation

BACKGROUND: There have been reports of serious complications associated with pedicle screw fixation, including nerve root injuries caused by accidental screw insertion. We have developed a new system of lumbar spinal instrumentation that we call Tadpole system(®). The purposes of this report were to...

Descripción completa

Detalles Bibliográficos
Autores principales: Kasai, Yuichi, Inaba, Tadashi, Akeda, Koji, Uchida, Atsumasa
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2565584/
https://www.ncbi.nlm.nih.gov/pubmed/18786272
http://dx.doi.org/10.1186/1749-799X-3-41
_version_ 1782159923297124352
author Kasai, Yuichi
Inaba, Tadashi
Akeda, Koji
Uchida, Atsumasa
author_facet Kasai, Yuichi
Inaba, Tadashi
Akeda, Koji
Uchida, Atsumasa
author_sort Kasai, Yuichi
collection PubMed
description BACKGROUND: There have been reports of serious complications associated with pedicle screw fixation, including nerve root injuries caused by accidental screw insertion. We have developed a new system of lumbar spinal instrumentation that we call Tadpole system(®). The purposes of this report were to show the results of a biomechanical study and the short-term outcome of a clinical study, as well as to determine the usefulness of this system. METHODS: The Tadpole system(® )lumbar spinal fusion is a hook-and-rod system according to which the spine is stabilized using 2 sets of 2 spinous processes each that are held in place by 4 hooks tandemly connected to a rod. The biomechanical study was done using 5 human lumbar cadaveric spines, and the range of motion (ROM) was examined in a non-treatment model, an injured model, a pedicle screw fixation model and a Tadpole system(® )model. For the short-term clinical study the Tadpole system(® )was used in 31 patients, and the factors analyzed were operation time, time required for spinal instrumentation, amount of intraoperative bleeding, postoperative improvement rate of the Japanese Orthopaedic Association (JOA) score for lumbar spinal disorders, instrumentation failure, spinous process fracture, spinal fluid leakage, nerve root injury, postoperative infection, and bone fusion 2 years after the operation. RESULTS: The ROM in the Tadpole system(® )model was slightly bigger than that in the pedicle screw fixation model, but smaller than that in the normal control model. These biomechanical data indicated that the Tadpole system(® )provided fairly good stability. The mean operation time was 79 min, the mean time required for spinal instrumentation was 8 min, and the mean amount of intraoperative bleeding was 340 mL. The mean postoperative improvement rate of JOA score was 70.9 ± 24.8%. Instrumentation failure (dislocation of a hook) occurred in one patient, and none of the patients developed spinous process fracture, spinal fluid leakage, nerve root injury, or postoperative infection. Two years after the operation, bone union was confirmed in 29 of the 31 patients (93.5%). CONCLUSION: We conclude that this system is a useful, easy-to-use and safe spinal instrumentation technique for lumbar fusion surgery.
format Text
id pubmed-2565584
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-25655842008-10-10 Tadpole system as new lumbar spinal instrumentation Kasai, Yuichi Inaba, Tadashi Akeda, Koji Uchida, Atsumasa J Orthop Surg Technical Note BACKGROUND: There have been reports of serious complications associated with pedicle screw fixation, including nerve root injuries caused by accidental screw insertion. We have developed a new system of lumbar spinal instrumentation that we call Tadpole system(®). The purposes of this report were to show the results of a biomechanical study and the short-term outcome of a clinical study, as well as to determine the usefulness of this system. METHODS: The Tadpole system(® )lumbar spinal fusion is a hook-and-rod system according to which the spine is stabilized using 2 sets of 2 spinous processes each that are held in place by 4 hooks tandemly connected to a rod. The biomechanical study was done using 5 human lumbar cadaveric spines, and the range of motion (ROM) was examined in a non-treatment model, an injured model, a pedicle screw fixation model and a Tadpole system(® )model. For the short-term clinical study the Tadpole system(® )was used in 31 patients, and the factors analyzed were operation time, time required for spinal instrumentation, amount of intraoperative bleeding, postoperative improvement rate of the Japanese Orthopaedic Association (JOA) score for lumbar spinal disorders, instrumentation failure, spinous process fracture, spinal fluid leakage, nerve root injury, postoperative infection, and bone fusion 2 years after the operation. RESULTS: The ROM in the Tadpole system(® )model was slightly bigger than that in the pedicle screw fixation model, but smaller than that in the normal control model. These biomechanical data indicated that the Tadpole system(® )provided fairly good stability. The mean operation time was 79 min, the mean time required for spinal instrumentation was 8 min, and the mean amount of intraoperative bleeding was 340 mL. The mean postoperative improvement rate of JOA score was 70.9 ± 24.8%. Instrumentation failure (dislocation of a hook) occurred in one patient, and none of the patients developed spinous process fracture, spinal fluid leakage, nerve root injury, or postoperative infection. Two years after the operation, bone union was confirmed in 29 of the 31 patients (93.5%). CONCLUSION: We conclude that this system is a useful, easy-to-use and safe spinal instrumentation technique for lumbar fusion surgery. BioMed Central 2008-09-12 /pmc/articles/PMC2565584/ /pubmed/18786272 http://dx.doi.org/10.1186/1749-799X-3-41 Text en Copyright © 2008 Kasai et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Note
Kasai, Yuichi
Inaba, Tadashi
Akeda, Koji
Uchida, Atsumasa
Tadpole system as new lumbar spinal instrumentation
title Tadpole system as new lumbar spinal instrumentation
title_full Tadpole system as new lumbar spinal instrumentation
title_fullStr Tadpole system as new lumbar spinal instrumentation
title_full_unstemmed Tadpole system as new lumbar spinal instrumentation
title_short Tadpole system as new lumbar spinal instrumentation
title_sort tadpole system as new lumbar spinal instrumentation
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2565584/
https://www.ncbi.nlm.nih.gov/pubmed/18786272
http://dx.doi.org/10.1186/1749-799X-3-41
work_keys_str_mv AT kasaiyuichi tadpolesystemasnewlumbarspinalinstrumentation
AT inabatadashi tadpolesystemasnewlumbarspinalinstrumentation
AT akedakoji tadpolesystemasnewlumbarspinalinstrumentation
AT uchidaatsumasa tadpolesystemasnewlumbarspinalinstrumentation