Cargando…
Autoadjusting-CPAP effect on serum Leptin concentrations in Obstructive Sleep Apnoea patients
BACKGROUND: Leptin is an hormone that regulates body weight. Studies have shown increasing leptin concentrations according to body mass index (BMI) and intermittent hypoxia. Our aim is to evaluate the basal leptin levels in OSA patients and its possible relation to OSA severity, independently of con...
Autores principales: | , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2567288/ https://www.ncbi.nlm.nih.gov/pubmed/18828917 http://dx.doi.org/10.1186/1471-2466-8-21 |
_version_ | 1782159996888285184 |
---|---|
author | Drummond, Marta Winck, João C Guimarães, João T Santos, Ana C Almeida, João Marques, José A |
author_facet | Drummond, Marta Winck, João C Guimarães, João T Santos, Ana C Almeida, João Marques, José A |
author_sort | Drummond, Marta |
collection | PubMed |
description | BACKGROUND: Leptin is an hormone that regulates body weight. Studies have shown increasing leptin concentrations according to body mass index (BMI) and intermittent hypoxia. Our aim is to evaluate the basal leptin levels in OSA patients and its possible relation to OSA severity, independently of confounders and investigate the Autoadjusting-CPAP effect on leptin values. METHODS: In ninety eight male patients with moderate to severe OSA leptin serum levels were evaluated before therapy, 9 days and 6 months after therapy. RESULTS: In this group mean age was 55.3 years, mean BMI was 33.2 Kg/m2 and mean Apnoea- Hypopnea Index (AHI) was 51.7/h. Mean basal serum leptin value was 12.1 ug/L. Univariate analysis showed a significant correlation between serum leptin values and BMI (R = 0.68; p < 0.001), waist-hip ratio (R = 0.283; p = 0.004) and AHI (R = 0.198; p = 0.048); in stepwise multiple regression analysis only BMI (p < 0.001) was a predictor of serum leptin values. One week after therapy, mean leptin serum level decreased to 11.0 ug/L and 6 months after it was 11.4 ug/L. (p = 0.56 and p = 0.387, respectively) CONCLUSION: Baseline leptin serum levels positively correlate with BMI, fat distributioand OSA severity. BMI is the only predictor of basal leptin levels. Treatment with Autoadjusting-CPAP has a small effect on leptin levels. |
format | Text |
id | pubmed-2567288 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2008 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-25672882008-10-15 Autoadjusting-CPAP effect on serum Leptin concentrations in Obstructive Sleep Apnoea patients Drummond, Marta Winck, João C Guimarães, João T Santos, Ana C Almeida, João Marques, José A BMC Pulm Med Research Article BACKGROUND: Leptin is an hormone that regulates body weight. Studies have shown increasing leptin concentrations according to body mass index (BMI) and intermittent hypoxia. Our aim is to evaluate the basal leptin levels in OSA patients and its possible relation to OSA severity, independently of confounders and investigate the Autoadjusting-CPAP effect on leptin values. METHODS: In ninety eight male patients with moderate to severe OSA leptin serum levels were evaluated before therapy, 9 days and 6 months after therapy. RESULTS: In this group mean age was 55.3 years, mean BMI was 33.2 Kg/m2 and mean Apnoea- Hypopnea Index (AHI) was 51.7/h. Mean basal serum leptin value was 12.1 ug/L. Univariate analysis showed a significant correlation between serum leptin values and BMI (R = 0.68; p < 0.001), waist-hip ratio (R = 0.283; p = 0.004) and AHI (R = 0.198; p = 0.048); in stepwise multiple regression analysis only BMI (p < 0.001) was a predictor of serum leptin values. One week after therapy, mean leptin serum level decreased to 11.0 ug/L and 6 months after it was 11.4 ug/L. (p = 0.56 and p = 0.387, respectively) CONCLUSION: Baseline leptin serum levels positively correlate with BMI, fat distributioand OSA severity. BMI is the only predictor of basal leptin levels. Treatment with Autoadjusting-CPAP has a small effect on leptin levels. BioMed Central 2008-10-01 /pmc/articles/PMC2567288/ /pubmed/18828917 http://dx.doi.org/10.1186/1471-2466-8-21 Text en Copyright © 2008 Drummond et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Drummond, Marta Winck, João C Guimarães, João T Santos, Ana C Almeida, João Marques, José A Autoadjusting-CPAP effect on serum Leptin concentrations in Obstructive Sleep Apnoea patients |
title | Autoadjusting-CPAP effect on serum Leptin concentrations in Obstructive Sleep Apnoea patients |
title_full | Autoadjusting-CPAP effect on serum Leptin concentrations in Obstructive Sleep Apnoea patients |
title_fullStr | Autoadjusting-CPAP effect on serum Leptin concentrations in Obstructive Sleep Apnoea patients |
title_full_unstemmed | Autoadjusting-CPAP effect on serum Leptin concentrations in Obstructive Sleep Apnoea patients |
title_short | Autoadjusting-CPAP effect on serum Leptin concentrations in Obstructive Sleep Apnoea patients |
title_sort | autoadjusting-cpap effect on serum leptin concentrations in obstructive sleep apnoea patients |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2567288/ https://www.ncbi.nlm.nih.gov/pubmed/18828917 http://dx.doi.org/10.1186/1471-2466-8-21 |
work_keys_str_mv | AT drummondmarta autoadjustingcpapeffectonserumleptinconcentrationsinobstructivesleepapnoeapatients AT winckjoaoc autoadjustingcpapeffectonserumleptinconcentrationsinobstructivesleepapnoeapatients AT guimaraesjoaot autoadjustingcpapeffectonserumleptinconcentrationsinobstructivesleepapnoeapatients AT santosanac autoadjustingcpapeffectonserumleptinconcentrationsinobstructivesleepapnoeapatients AT almeidajoao autoadjustingcpapeffectonserumleptinconcentrationsinobstructivesleepapnoeapatients AT marquesjosea autoadjustingcpapeffectonserumleptinconcentrationsinobstructivesleepapnoeapatients |