Cargando…

The Enhancement of the N1 Wave Elicited by Sensory Stimuli Presented at Very Short Inter-Stimulus Intervals Is a General Feature across Sensory Systems

BACKGROUND: A paradoxical enhancement of the magnitude of the N1 wave of the auditory event-related potential (ERP) has been described when auditory stimuli are presented at very short (<400 ms) inter-stimulus intervals (ISI). Here, we examined whether this enhancement is specific for the auditor...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, An Li, Mouraux, André, Liang, Meng, Iannetti, Gian Domenico
Formato: Texto
Lenguaje:English
Publicado: Public Library of Science 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2597742/
https://www.ncbi.nlm.nih.gov/pubmed/19081790
http://dx.doi.org/10.1371/journal.pone.0003929
_version_ 1782161896057602048
author Wang, An Li
Mouraux, André
Liang, Meng
Iannetti, Gian Domenico
author_facet Wang, An Li
Mouraux, André
Liang, Meng
Iannetti, Gian Domenico
author_sort Wang, An Li
collection PubMed
description BACKGROUND: A paradoxical enhancement of the magnitude of the N1 wave of the auditory event-related potential (ERP) has been described when auditory stimuli are presented at very short (<400 ms) inter-stimulus intervals (ISI). Here, we examined whether this enhancement is specific for the auditory system, or whether it also affects ERPs elicited by stimuli belonging to other sensory modalities. METHODOLOGY AND PRINCIPAL FINDINGS: We recorded ERPs elicited by auditory and somatosensory stimuli in 13 healthy subjects. For each sensory modality, 4800 stimuli were presented. Auditory stimuli consisted in brief tones presented binaurally, and somatosensory stimuli consisted in constant-current electrical pulses applied to the right median nerve. Stimuli were delivered continuously, and the ISI was varied randomly between 100 and 1000 ms. We found that the ISI had a similar effect on both auditory and somatosensory ERPs. In both sensory modalities, ISI had an opposite effect on the magnitude of the N1 and P2 waves: the magnitude of the auditory and the somatosensory N1 was significantly increased at ISI≤200 ms, while the magnitude of the auditory and the somatosensory P2 was significantly decreased at ISI≤200 ms. CONCLUSION AND SIGNIFICANCE: The observation that both the auditory and the somatosensory N1 are enhanced at short ISIs indicates that this phenomenon reflects a physiological property that is common across sensory systems, rather than, as previously suggested, unique for the auditory system. Two of the hypotheses most frequently put forward to explain this observation, namely (i) the decreased contribution of inhibitory postsynaptic potentials to the recorded scalp ERPs and (ii) the decreased contribution of ‘latent inhibition’, are discussed. Because neither of these two hypotheses can satisfactorily account for the concomitant reduction of the auditory and the somatosensory P2, we propose a third, novel hypothesis, consisting in the modulation of a single neural component contributing to both the N1 and the P2 waves.
format Text
id pubmed-2597742
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-25977422008-12-12 The Enhancement of the N1 Wave Elicited by Sensory Stimuli Presented at Very Short Inter-Stimulus Intervals Is a General Feature across Sensory Systems Wang, An Li Mouraux, André Liang, Meng Iannetti, Gian Domenico PLoS One Research Article BACKGROUND: A paradoxical enhancement of the magnitude of the N1 wave of the auditory event-related potential (ERP) has been described when auditory stimuli are presented at very short (<400 ms) inter-stimulus intervals (ISI). Here, we examined whether this enhancement is specific for the auditory system, or whether it also affects ERPs elicited by stimuli belonging to other sensory modalities. METHODOLOGY AND PRINCIPAL FINDINGS: We recorded ERPs elicited by auditory and somatosensory stimuli in 13 healthy subjects. For each sensory modality, 4800 stimuli were presented. Auditory stimuli consisted in brief tones presented binaurally, and somatosensory stimuli consisted in constant-current electrical pulses applied to the right median nerve. Stimuli were delivered continuously, and the ISI was varied randomly between 100 and 1000 ms. We found that the ISI had a similar effect on both auditory and somatosensory ERPs. In both sensory modalities, ISI had an opposite effect on the magnitude of the N1 and P2 waves: the magnitude of the auditory and the somatosensory N1 was significantly increased at ISI≤200 ms, while the magnitude of the auditory and the somatosensory P2 was significantly decreased at ISI≤200 ms. CONCLUSION AND SIGNIFICANCE: The observation that both the auditory and the somatosensory N1 are enhanced at short ISIs indicates that this phenomenon reflects a physiological property that is common across sensory systems, rather than, as previously suggested, unique for the auditory system. Two of the hypotheses most frequently put forward to explain this observation, namely (i) the decreased contribution of inhibitory postsynaptic potentials to the recorded scalp ERPs and (ii) the decreased contribution of ‘latent inhibition’, are discussed. Because neither of these two hypotheses can satisfactorily account for the concomitant reduction of the auditory and the somatosensory P2, we propose a third, novel hypothesis, consisting in the modulation of a single neural component contributing to both the N1 and the P2 waves. Public Library of Science 2008-12-12 /pmc/articles/PMC2597742/ /pubmed/19081790 http://dx.doi.org/10.1371/journal.pone.0003929 Text en Wang et al. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Wang, An Li
Mouraux, André
Liang, Meng
Iannetti, Gian Domenico
The Enhancement of the N1 Wave Elicited by Sensory Stimuli Presented at Very Short Inter-Stimulus Intervals Is a General Feature across Sensory Systems
title The Enhancement of the N1 Wave Elicited by Sensory Stimuli Presented at Very Short Inter-Stimulus Intervals Is a General Feature across Sensory Systems
title_full The Enhancement of the N1 Wave Elicited by Sensory Stimuli Presented at Very Short Inter-Stimulus Intervals Is a General Feature across Sensory Systems
title_fullStr The Enhancement of the N1 Wave Elicited by Sensory Stimuli Presented at Very Short Inter-Stimulus Intervals Is a General Feature across Sensory Systems
title_full_unstemmed The Enhancement of the N1 Wave Elicited by Sensory Stimuli Presented at Very Short Inter-Stimulus Intervals Is a General Feature across Sensory Systems
title_short The Enhancement of the N1 Wave Elicited by Sensory Stimuli Presented at Very Short Inter-Stimulus Intervals Is a General Feature across Sensory Systems
title_sort enhancement of the n1 wave elicited by sensory stimuli presented at very short inter-stimulus intervals is a general feature across sensory systems
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2597742/
https://www.ncbi.nlm.nih.gov/pubmed/19081790
http://dx.doi.org/10.1371/journal.pone.0003929
work_keys_str_mv AT wanganli theenhancementofthen1waveelicitedbysensorystimulipresentedatveryshortinterstimulusintervalsisageneralfeatureacrosssensorysystems
AT mourauxandre theenhancementofthen1waveelicitedbysensorystimulipresentedatveryshortinterstimulusintervalsisageneralfeatureacrosssensorysystems
AT liangmeng theenhancementofthen1waveelicitedbysensorystimulipresentedatveryshortinterstimulusintervalsisageneralfeatureacrosssensorysystems
AT iannettigiandomenico theenhancementofthen1waveelicitedbysensorystimulipresentedatveryshortinterstimulusintervalsisageneralfeatureacrosssensorysystems
AT wanganli enhancementofthen1waveelicitedbysensorystimulipresentedatveryshortinterstimulusintervalsisageneralfeatureacrosssensorysystems
AT mourauxandre enhancementofthen1waveelicitedbysensorystimulipresentedatveryshortinterstimulusintervalsisageneralfeatureacrosssensorysystems
AT liangmeng enhancementofthen1waveelicitedbysensorystimulipresentedatveryshortinterstimulusintervalsisageneralfeatureacrosssensorysystems
AT iannettigiandomenico enhancementofthen1waveelicitedbysensorystimulipresentedatveryshortinterstimulusintervalsisageneralfeatureacrosssensorysystems