Cargando…

Field evaluation of a new particle concentrator- electrostatic precipitator system for measuring chemical and toxicological properties of particulate matter

BACKGROUND: A newly designed electrostatic precipitator (ESP) in tandem with Versatile Aerosol Concentration Enrichment System (VACES) was developed by the University of Southern California to collect ambient aerosols on substrates appropriate for chemical and toxicological analysis. The laboratory...

Descripción completa

Detalles Bibliográficos
Autores principales: Ning, Zhi, Sillanpää, Markus, Pakbin, Payam, Sioutas, Constantinos
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2603041/
https://www.ncbi.nlm.nih.gov/pubmed/19014466
http://dx.doi.org/10.1186/1743-8977-5-15
_version_ 1782162554309574656
author Ning, Zhi
Sillanpää, Markus
Pakbin, Payam
Sioutas, Constantinos
author_facet Ning, Zhi
Sillanpää, Markus
Pakbin, Payam
Sioutas, Constantinos
author_sort Ning, Zhi
collection PubMed
description BACKGROUND: A newly designed electrostatic precipitator (ESP) in tandem with Versatile Aerosol Concentration Enrichment System (VACES) was developed by the University of Southern California to collect ambient aerosols on substrates appropriate for chemical and toxicological analysis. The laboratory evaluation of this sampler is described in a previous paper. The main objective of this study was to evaluate the performance of the new VACES-ESP system in the field by comparing the chemical characteristics of the PM collected in the ESP to those of reference samplers operating in parallel. RESULTS: The field campaign was carried out in the period from August, 2007 to March, 2008 in a typical urban environment near downtown Los Angeles. Each sampling set was restricted to 2–3 hours to minimize possible sampling artifacts in the ESP. The results showed that particle penetration increases and ozone concentration decreases with increasing sampling flow rate, with highest particle penetration observed between 100 nm and 300 nm. A reference filter sampler was deployed in parallel to the ESP to collect concentration-enriched aerosols, and a MOUDI sampler was used to collect ambient aerosols. Chemical analysis results showed very good agreement between the ESP and MOUDI samplers in the concentrations of trace elements and inorganic ions. The overall organic compound content of PM collected by the ESP, including polycyclic aromatic hydrocarbons (PAHs), hopanes, steranes, and alkanes, was in good agreement with that of the reference sampler, with an average ESP -to -reference concentration ratio of 1.07 (± 0.38). While majority of organic compound ratios were close to 1, some of the semi-volatile organic species had slightly deviated ratios from 1, indicating the possibility of some sampling artifacts in the ESP due to reactions of PM with ozone and radicals generated from corona discharge, although positive and negative sampling artifacts in the reference filter sampler cannot be ruled out. CONCLUSION: The very good overall agreement between ESP and reference samplers makes it an attractive alternative to filters and biosamplers for chemical and toxicological evaluation of PM properties, including the possibility of conducting direct in vitro cell exposures. Moreover, the concentration enrichment of ambient aerosols by the VACES allows for short-term exposure studies, which preserve cell viability and enable studies to PM generated from specific sources and-or formation mechanisms in the atmosphere.
format Text
id pubmed-2603041
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-26030412008-12-16 Field evaluation of a new particle concentrator- electrostatic precipitator system for measuring chemical and toxicological properties of particulate matter Ning, Zhi Sillanpää, Markus Pakbin, Payam Sioutas, Constantinos Part Fibre Toxicol Research BACKGROUND: A newly designed electrostatic precipitator (ESP) in tandem with Versatile Aerosol Concentration Enrichment System (VACES) was developed by the University of Southern California to collect ambient aerosols on substrates appropriate for chemical and toxicological analysis. The laboratory evaluation of this sampler is described in a previous paper. The main objective of this study was to evaluate the performance of the new VACES-ESP system in the field by comparing the chemical characteristics of the PM collected in the ESP to those of reference samplers operating in parallel. RESULTS: The field campaign was carried out in the period from August, 2007 to March, 2008 in a typical urban environment near downtown Los Angeles. Each sampling set was restricted to 2–3 hours to minimize possible sampling artifacts in the ESP. The results showed that particle penetration increases and ozone concentration decreases with increasing sampling flow rate, with highest particle penetration observed between 100 nm and 300 nm. A reference filter sampler was deployed in parallel to the ESP to collect concentration-enriched aerosols, and a MOUDI sampler was used to collect ambient aerosols. Chemical analysis results showed very good agreement between the ESP and MOUDI samplers in the concentrations of trace elements and inorganic ions. The overall organic compound content of PM collected by the ESP, including polycyclic aromatic hydrocarbons (PAHs), hopanes, steranes, and alkanes, was in good agreement with that of the reference sampler, with an average ESP -to -reference concentration ratio of 1.07 (± 0.38). While majority of organic compound ratios were close to 1, some of the semi-volatile organic species had slightly deviated ratios from 1, indicating the possibility of some sampling artifacts in the ESP due to reactions of PM with ozone and radicals generated from corona discharge, although positive and negative sampling artifacts in the reference filter sampler cannot be ruled out. CONCLUSION: The very good overall agreement between ESP and reference samplers makes it an attractive alternative to filters and biosamplers for chemical and toxicological evaluation of PM properties, including the possibility of conducting direct in vitro cell exposures. Moreover, the concentration enrichment of ambient aerosols by the VACES allows for short-term exposure studies, which preserve cell viability and enable studies to PM generated from specific sources and-or formation mechanisms in the atmosphere. BioMed Central 2008-11-11 /pmc/articles/PMC2603041/ /pubmed/19014466 http://dx.doi.org/10.1186/1743-8977-5-15 Text en Copyright © 2008 Ning et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Ning, Zhi
Sillanpää, Markus
Pakbin, Payam
Sioutas, Constantinos
Field evaluation of a new particle concentrator- electrostatic precipitator system for measuring chemical and toxicological properties of particulate matter
title Field evaluation of a new particle concentrator- electrostatic precipitator system for measuring chemical and toxicological properties of particulate matter
title_full Field evaluation of a new particle concentrator- electrostatic precipitator system for measuring chemical and toxicological properties of particulate matter
title_fullStr Field evaluation of a new particle concentrator- electrostatic precipitator system for measuring chemical and toxicological properties of particulate matter
title_full_unstemmed Field evaluation of a new particle concentrator- electrostatic precipitator system for measuring chemical and toxicological properties of particulate matter
title_short Field evaluation of a new particle concentrator- electrostatic precipitator system for measuring chemical and toxicological properties of particulate matter
title_sort field evaluation of a new particle concentrator- electrostatic precipitator system for measuring chemical and toxicological properties of particulate matter
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2603041/
https://www.ncbi.nlm.nih.gov/pubmed/19014466
http://dx.doi.org/10.1186/1743-8977-5-15
work_keys_str_mv AT ningzhi fieldevaluationofanewparticleconcentratorelectrostaticprecipitatorsystemformeasuringchemicalandtoxicologicalpropertiesofparticulatematter
AT sillanpaamarkus fieldevaluationofanewparticleconcentratorelectrostaticprecipitatorsystemformeasuringchemicalandtoxicologicalpropertiesofparticulatematter
AT pakbinpayam fieldevaluationofanewparticleconcentratorelectrostaticprecipitatorsystemformeasuringchemicalandtoxicologicalpropertiesofparticulatematter
AT sioutasconstantinos fieldevaluationofanewparticleconcentratorelectrostaticprecipitatorsystemformeasuringchemicalandtoxicologicalpropertiesofparticulatematter