Cargando…
Field evaluation of a new particle concentrator- electrostatic precipitator system for measuring chemical and toxicological properties of particulate matter
BACKGROUND: A newly designed electrostatic precipitator (ESP) in tandem with Versatile Aerosol Concentration Enrichment System (VACES) was developed by the University of Southern California to collect ambient aerosols on substrates appropriate for chemical and toxicological analysis. The laboratory...
Autores principales: | , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2603041/ https://www.ncbi.nlm.nih.gov/pubmed/19014466 http://dx.doi.org/10.1186/1743-8977-5-15 |
_version_ | 1782162554309574656 |
---|---|
author | Ning, Zhi Sillanpää, Markus Pakbin, Payam Sioutas, Constantinos |
author_facet | Ning, Zhi Sillanpää, Markus Pakbin, Payam Sioutas, Constantinos |
author_sort | Ning, Zhi |
collection | PubMed |
description | BACKGROUND: A newly designed electrostatic precipitator (ESP) in tandem with Versatile Aerosol Concentration Enrichment System (VACES) was developed by the University of Southern California to collect ambient aerosols on substrates appropriate for chemical and toxicological analysis. The laboratory evaluation of this sampler is described in a previous paper. The main objective of this study was to evaluate the performance of the new VACES-ESP system in the field by comparing the chemical characteristics of the PM collected in the ESP to those of reference samplers operating in parallel. RESULTS: The field campaign was carried out in the period from August, 2007 to March, 2008 in a typical urban environment near downtown Los Angeles. Each sampling set was restricted to 2–3 hours to minimize possible sampling artifacts in the ESP. The results showed that particle penetration increases and ozone concentration decreases with increasing sampling flow rate, with highest particle penetration observed between 100 nm and 300 nm. A reference filter sampler was deployed in parallel to the ESP to collect concentration-enriched aerosols, and a MOUDI sampler was used to collect ambient aerosols. Chemical analysis results showed very good agreement between the ESP and MOUDI samplers in the concentrations of trace elements and inorganic ions. The overall organic compound content of PM collected by the ESP, including polycyclic aromatic hydrocarbons (PAHs), hopanes, steranes, and alkanes, was in good agreement with that of the reference sampler, with an average ESP -to -reference concentration ratio of 1.07 (± 0.38). While majority of organic compound ratios were close to 1, some of the semi-volatile organic species had slightly deviated ratios from 1, indicating the possibility of some sampling artifacts in the ESP due to reactions of PM with ozone and radicals generated from corona discharge, although positive and negative sampling artifacts in the reference filter sampler cannot be ruled out. CONCLUSION: The very good overall agreement between ESP and reference samplers makes it an attractive alternative to filters and biosamplers for chemical and toxicological evaluation of PM properties, including the possibility of conducting direct in vitro cell exposures. Moreover, the concentration enrichment of ambient aerosols by the VACES allows for short-term exposure studies, which preserve cell viability and enable studies to PM generated from specific sources and-or formation mechanisms in the atmosphere. |
format | Text |
id | pubmed-2603041 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2008 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-26030412008-12-16 Field evaluation of a new particle concentrator- electrostatic precipitator system for measuring chemical and toxicological properties of particulate matter Ning, Zhi Sillanpää, Markus Pakbin, Payam Sioutas, Constantinos Part Fibre Toxicol Research BACKGROUND: A newly designed electrostatic precipitator (ESP) in tandem with Versatile Aerosol Concentration Enrichment System (VACES) was developed by the University of Southern California to collect ambient aerosols on substrates appropriate for chemical and toxicological analysis. The laboratory evaluation of this sampler is described in a previous paper. The main objective of this study was to evaluate the performance of the new VACES-ESP system in the field by comparing the chemical characteristics of the PM collected in the ESP to those of reference samplers operating in parallel. RESULTS: The field campaign was carried out in the period from August, 2007 to March, 2008 in a typical urban environment near downtown Los Angeles. Each sampling set was restricted to 2–3 hours to minimize possible sampling artifacts in the ESP. The results showed that particle penetration increases and ozone concentration decreases with increasing sampling flow rate, with highest particle penetration observed between 100 nm and 300 nm. A reference filter sampler was deployed in parallel to the ESP to collect concentration-enriched aerosols, and a MOUDI sampler was used to collect ambient aerosols. Chemical analysis results showed very good agreement between the ESP and MOUDI samplers in the concentrations of trace elements and inorganic ions. The overall organic compound content of PM collected by the ESP, including polycyclic aromatic hydrocarbons (PAHs), hopanes, steranes, and alkanes, was in good agreement with that of the reference sampler, with an average ESP -to -reference concentration ratio of 1.07 (± 0.38). While majority of organic compound ratios were close to 1, some of the semi-volatile organic species had slightly deviated ratios from 1, indicating the possibility of some sampling artifacts in the ESP due to reactions of PM with ozone and radicals generated from corona discharge, although positive and negative sampling artifacts in the reference filter sampler cannot be ruled out. CONCLUSION: The very good overall agreement between ESP and reference samplers makes it an attractive alternative to filters and biosamplers for chemical and toxicological evaluation of PM properties, including the possibility of conducting direct in vitro cell exposures. Moreover, the concentration enrichment of ambient aerosols by the VACES allows for short-term exposure studies, which preserve cell viability and enable studies to PM generated from specific sources and-or formation mechanisms in the atmosphere. BioMed Central 2008-11-11 /pmc/articles/PMC2603041/ /pubmed/19014466 http://dx.doi.org/10.1186/1743-8977-5-15 Text en Copyright © 2008 Ning et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Ning, Zhi Sillanpää, Markus Pakbin, Payam Sioutas, Constantinos Field evaluation of a new particle concentrator- electrostatic precipitator system for measuring chemical and toxicological properties of particulate matter |
title | Field evaluation of a new particle concentrator- electrostatic precipitator system for measuring chemical and toxicological properties of particulate matter |
title_full | Field evaluation of a new particle concentrator- electrostatic precipitator system for measuring chemical and toxicological properties of particulate matter |
title_fullStr | Field evaluation of a new particle concentrator- electrostatic precipitator system for measuring chemical and toxicological properties of particulate matter |
title_full_unstemmed | Field evaluation of a new particle concentrator- electrostatic precipitator system for measuring chemical and toxicological properties of particulate matter |
title_short | Field evaluation of a new particle concentrator- electrostatic precipitator system for measuring chemical and toxicological properties of particulate matter |
title_sort | field evaluation of a new particle concentrator- electrostatic precipitator system for measuring chemical and toxicological properties of particulate matter |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2603041/ https://www.ncbi.nlm.nih.gov/pubmed/19014466 http://dx.doi.org/10.1186/1743-8977-5-15 |
work_keys_str_mv | AT ningzhi fieldevaluationofanewparticleconcentratorelectrostaticprecipitatorsystemformeasuringchemicalandtoxicologicalpropertiesofparticulatematter AT sillanpaamarkus fieldevaluationofanewparticleconcentratorelectrostaticprecipitatorsystemformeasuringchemicalandtoxicologicalpropertiesofparticulatematter AT pakbinpayam fieldevaluationofanewparticleconcentratorelectrostaticprecipitatorsystemformeasuringchemicalandtoxicologicalpropertiesofparticulatematter AT sioutasconstantinos fieldevaluationofanewparticleconcentratorelectrostaticprecipitatorsystemformeasuringchemicalandtoxicologicalpropertiesofparticulatematter |