Temperature Rise Within the Pulp Chamber During Composite Resin Polymerisation Using Three Different Light Sources

The purpose of the study was to compare temperature rise during polymerisation of resin based composites (RBCs) with two LED light curing units (LCUs) compared to a halogen control light. METHODS: Forty-five extracted molars, patients aging 11-18 years were used. Thermocouples (TCs) were placed in c...

Descripción completa

Detalles Bibliográficos
Autores principales: Santini, A, Watterson, C, Miletic, V
Formato: Texto
Lenguaje:English
Publicado: Bentham Open 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2606658/
https://www.ncbi.nlm.nih.gov/pubmed/19444316
http://dx.doi.org/10.2174/1874210600802010137
_version_ 1782162981081055232
author Santini, A
Watterson, C
Miletic, V
author_facet Santini, A
Watterson, C
Miletic, V
author_sort Santini, A
collection PubMed
description The purpose of the study was to compare temperature rise during polymerisation of resin based composites (RBCs) with two LED light curing units (LCUs) compared to a halogen control light. METHODS: Forty-five extracted molars, patients aging 11-18 years were used. Thermocouples (TCs) were placed in contact with the roof of the pulp chamber using a ‘split-tooth’ method. Teeth were placed in a water bath with the temperature of the pulp chamber regulated at 37°±1°C. GROUP 1 (CONTROL): Prismatics(®) Lite II (Dentsply Detrey, Konstanz, Germany), a halogen LCU, light intensity 500 mW/cm(2). GROUP 2: Bluephase(®) ( Ivoclar Vivadent, Schaan, Liechtenstein), light intensity 1100 mW/cm(2). Group 3:Elipar Freelight2 (3M ESPE, Seefeld, Germany), light intensity 1000 mW/cm(2). Temperature changes were continuously recorded with a data logger connected to a PC. RESULTS: Significantly higher temperature rise was recorded during bond curing than RBC curing in all 3 groups. (Halogen; p =0.0003: Bluephase; p=0.0043: Elipar; p=0.0002.). Higher temperatures were recorded during polymerisation of both Bond and RBC with both LED sources than with the halogen control. There was no significant difference between the two LED,LCUs (Bond:p=0.0279: RBC p=0.0562: Mann-Whitney). CONCLUSION: The potential risk of pulpal injury during RBC polymerisation is increased when using light-curing units with high energy output compared to low energy output light sources. The rise is greatest when curing bonding agent alone and clinicians are advised to be aware of the potential hazard of thermal trauma to the pulp when using high intensity light sources. However the mean temperature rise with all three units was below the limits normally associated with permanent pulp damage.
format Text
id pubmed-2606658
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher Bentham Open
record_format MEDLINE/PubMed
spelling pubmed-26066582009-05-14 Temperature Rise Within the Pulp Chamber During Composite Resin Polymerisation Using Three Different Light Sources Santini, A Watterson, C Miletic, V Open Dent J Article The purpose of the study was to compare temperature rise during polymerisation of resin based composites (RBCs) with two LED light curing units (LCUs) compared to a halogen control light. METHODS: Forty-five extracted molars, patients aging 11-18 years were used. Thermocouples (TCs) were placed in contact with the roof of the pulp chamber using a ‘split-tooth’ method. Teeth were placed in a water bath with the temperature of the pulp chamber regulated at 37°±1°C. GROUP 1 (CONTROL): Prismatics(®) Lite II (Dentsply Detrey, Konstanz, Germany), a halogen LCU, light intensity 500 mW/cm(2). GROUP 2: Bluephase(®) ( Ivoclar Vivadent, Schaan, Liechtenstein), light intensity 1100 mW/cm(2). Group 3:Elipar Freelight2 (3M ESPE, Seefeld, Germany), light intensity 1000 mW/cm(2). Temperature changes were continuously recorded with a data logger connected to a PC. RESULTS: Significantly higher temperature rise was recorded during bond curing than RBC curing in all 3 groups. (Halogen; p =0.0003: Bluephase; p=0.0043: Elipar; p=0.0002.). Higher temperatures were recorded during polymerisation of both Bond and RBC with both LED sources than with the halogen control. There was no significant difference between the two LED,LCUs (Bond:p=0.0279: RBC p=0.0562: Mann-Whitney). CONCLUSION: The potential risk of pulpal injury during RBC polymerisation is increased when using light-curing units with high energy output compared to low energy output light sources. The rise is greatest when curing bonding agent alone and clinicians are advised to be aware of the potential hazard of thermal trauma to the pulp when using high intensity light sources. However the mean temperature rise with all three units was below the limits normally associated with permanent pulp damage. Bentham Open 2008-12-05 /pmc/articles/PMC2606658/ /pubmed/19444316 http://dx.doi.org/10.2174/1874210600802010137 Text en © Santini et al.; Licensee Bentham Open. http://creativecommons.org/licenses/by-nc/3.0/) This is an open access article licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited.
spellingShingle Article
Santini, A
Watterson, C
Miletic, V
Temperature Rise Within the Pulp Chamber During Composite Resin Polymerisation Using Three Different Light Sources
title Temperature Rise Within the Pulp Chamber During Composite Resin Polymerisation Using Three Different Light Sources
title_full Temperature Rise Within the Pulp Chamber During Composite Resin Polymerisation Using Three Different Light Sources
title_fullStr Temperature Rise Within the Pulp Chamber During Composite Resin Polymerisation Using Three Different Light Sources
title_full_unstemmed Temperature Rise Within the Pulp Chamber During Composite Resin Polymerisation Using Three Different Light Sources
title_short Temperature Rise Within the Pulp Chamber During Composite Resin Polymerisation Using Three Different Light Sources
title_sort temperature rise within the pulp chamber during composite resin polymerisation using three different light sources
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2606658/
https://www.ncbi.nlm.nih.gov/pubmed/19444316
http://dx.doi.org/10.2174/1874210600802010137
work_keys_str_mv AT santinia temperaturerisewithinthepulpchamberduringcompositeresinpolymerisationusingthreedifferentlightsources
AT wattersonc temperaturerisewithinthepulpchamberduringcompositeresinpolymerisationusingthreedifferentlightsources
AT mileticv temperaturerisewithinthepulpchamberduringcompositeresinpolymerisationusingthreedifferentlightsources