Influence of bone density on implant stability parameters and implant success: a retrospective clinical study
BACKGROUND: The aim of the present clinical study was to determine the local bone density in dental implant recipient sites using computerized tomography (CT) and to investigate the influence of local bone density on implant stability parameters and implant success. METHODS: A total of 300 implants...
Autores principales: | , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2614413/ https://www.ncbi.nlm.nih.gov/pubmed/19025637 http://dx.doi.org/10.1186/1472-6831-8-32 |
_version_ | 1782163226612465664 |
---|---|
author | Turkyilmaz, Ilser McGlumphy, Edwin A |
author_facet | Turkyilmaz, Ilser McGlumphy, Edwin A |
author_sort | Turkyilmaz, Ilser |
collection | PubMed |
description | BACKGROUND: The aim of the present clinical study was to determine the local bone density in dental implant recipient sites using computerized tomography (CT) and to investigate the influence of local bone density on implant stability parameters and implant success. METHODS: A total of 300 implants were placed in 111 patients between 2003 and 2005. The bone density in each implant recipient site was determined using CT. Insertion torque and resonance frequency analysis were used as implant stability parameters. The peak insertion torque values were recorded with OsseoCare machine. The resonance frequency analysis measurements were performed with Osstell instrument immediately after implant placement, 6, and 12 months later. RESULTS: Of 300 implants placed, 20 were lost, meaning a survival rate of %. 93.3 after three years (average 3.7 ± 0.7 years). The mean bone density, insertion torque and RFA recordings of all 300 implants were 620 ± 251 HU, 36.1 ± 8 Ncm, and 65.7 ± 9 ISQ at implant placement respectively; which indicated statistically significant correlations between bone density and insertion torque values (p < 0.001), bone density and ISQ values (p < 0.001), and insertion torque and ISQ values (p < 0.001). The mean bone density, insertion torque and RFA values were 645 ± 240 HU, 37.2 ± 7 Ncm, and 67.1 ± 7 ISQ for 280 successful implants at implant placement, while corresponding values were 267 ± 47 HU, 21.8 ± 4 Ncm, and 46.5 ± 4 ISQ for 20 failed implants; which indicated statistically significant differences for each parameter (p < 0.001). CONCLUSION: CT is a useful tool to determine the bone density in the implant recipient sites, and the local bone density has a prevailing influence on primary implant stability, which is an important determinant for implant success. |
format | Text |
id | pubmed-2614413 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2008 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-26144132009-01-07 Influence of bone density on implant stability parameters and implant success: a retrospective clinical study Turkyilmaz, Ilser McGlumphy, Edwin A BMC Oral Health Research Article BACKGROUND: The aim of the present clinical study was to determine the local bone density in dental implant recipient sites using computerized tomography (CT) and to investigate the influence of local bone density on implant stability parameters and implant success. METHODS: A total of 300 implants were placed in 111 patients between 2003 and 2005. The bone density in each implant recipient site was determined using CT. Insertion torque and resonance frequency analysis were used as implant stability parameters. The peak insertion torque values were recorded with OsseoCare machine. The resonance frequency analysis measurements were performed with Osstell instrument immediately after implant placement, 6, and 12 months later. RESULTS: Of 300 implants placed, 20 were lost, meaning a survival rate of %. 93.3 after three years (average 3.7 ± 0.7 years). The mean bone density, insertion torque and RFA recordings of all 300 implants were 620 ± 251 HU, 36.1 ± 8 Ncm, and 65.7 ± 9 ISQ at implant placement respectively; which indicated statistically significant correlations between bone density and insertion torque values (p < 0.001), bone density and ISQ values (p < 0.001), and insertion torque and ISQ values (p < 0.001). The mean bone density, insertion torque and RFA values were 645 ± 240 HU, 37.2 ± 7 Ncm, and 67.1 ± 7 ISQ for 280 successful implants at implant placement, while corresponding values were 267 ± 47 HU, 21.8 ± 4 Ncm, and 46.5 ± 4 ISQ for 20 failed implants; which indicated statistically significant differences for each parameter (p < 0.001). CONCLUSION: CT is a useful tool to determine the bone density in the implant recipient sites, and the local bone density has a prevailing influence on primary implant stability, which is an important determinant for implant success. BioMed Central 2008-11-24 /pmc/articles/PMC2614413/ /pubmed/19025637 http://dx.doi.org/10.1186/1472-6831-8-32 Text en Copyright © 2008 Turkyilmaz and McGlumphy; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Turkyilmaz, Ilser McGlumphy, Edwin A Influence of bone density on implant stability parameters and implant success: a retrospective clinical study |
title | Influence of bone density on implant stability parameters and implant success: a retrospective clinical study |
title_full | Influence of bone density on implant stability parameters and implant success: a retrospective clinical study |
title_fullStr | Influence of bone density on implant stability parameters and implant success: a retrospective clinical study |
title_full_unstemmed | Influence of bone density on implant stability parameters and implant success: a retrospective clinical study |
title_short | Influence of bone density on implant stability parameters and implant success: a retrospective clinical study |
title_sort | influence of bone density on implant stability parameters and implant success: a retrospective clinical study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2614413/ https://www.ncbi.nlm.nih.gov/pubmed/19025637 http://dx.doi.org/10.1186/1472-6831-8-32 |
work_keys_str_mv | AT turkyilmazilser influenceofbonedensityonimplantstabilityparametersandimplantsuccessaretrospectiveclinicalstudy AT mcglumphyedwina influenceofbonedensityonimplantstabilityparametersandimplantsuccessaretrospectiveclinicalstudy |