Termination of Ventricular Tachycardia with Antitachycardia Pacing after Ineffective Shock Therapy in an ICD Recipient with Hypertrophic Cardiomyopathy
Implantable Cardioverter Defibrillator (ICD) implantation is the only established therapy for primary or secondary prevention of sudden cardiac death in patients with Hypertrophic Cardiomyopathy (HCM). Ineffectiveness of shock therapy for the termination of potentially fatal ventricular arrhythmias...
Autores principales: | , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Indian Heart Rhythm Society
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2615065/ https://www.ncbi.nlm.nih.gov/pubmed/19165362 |
_version_ | 1782163283328892928 |
---|---|
author | Margos, Panagiotis N Schomburg, Rolf Kynast, Jorg Khattab, Ahmed A Richardt, Gert |
author_facet | Margos, Panagiotis N Schomburg, Rolf Kynast, Jorg Khattab, Ahmed A Richardt, Gert |
author_sort | Margos, Panagiotis N |
collection | PubMed |
description | Implantable Cardioverter Defibrillator (ICD) implantation is the only established therapy for primary or secondary prevention of sudden cardiac death in patients with Hypertrophic Cardiomyopathy (HCM). Ineffectiveness of shock therapy for the termination of potentially fatal ventricular arrhythmias in ICD recipients is rare in the presence of appropriate arrhythmia detection by the device. We report the case of a 48-year-old woman with HCM and a single chamber ICD, who received five inefficient high-energy (35 Joules) shocks for the termination of an appropriately detected episode of Ventricular Tachycardia (VT). The episode was safely terminated with a subsequent application of Antitachycardia Pacing (ATP) by the device. At the following ICD control, an acceptable defibrillation threshold was detected. |
format | Text |
id | pubmed-2615065 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | Indian Heart Rhythm Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-26150652009-01-22 Termination of Ventricular Tachycardia with Antitachycardia Pacing after Ineffective Shock Therapy in an ICD Recipient with Hypertrophic Cardiomyopathy Margos, Panagiotis N Schomburg, Rolf Kynast, Jorg Khattab, Ahmed A Richardt, Gert Indian Pacing Electrophysiol J Case Report Implantable Cardioverter Defibrillator (ICD) implantation is the only established therapy for primary or secondary prevention of sudden cardiac death in patients with Hypertrophic Cardiomyopathy (HCM). Ineffectiveness of shock therapy for the termination of potentially fatal ventricular arrhythmias in ICD recipients is rare in the presence of appropriate arrhythmia detection by the device. We report the case of a 48-year-old woman with HCM and a single chamber ICD, who received five inefficient high-energy (35 Joules) shocks for the termination of an appropriately detected episode of Ventricular Tachycardia (VT). The episode was safely terminated with a subsequent application of Antitachycardia Pacing (ATP) by the device. At the following ICD control, an acceptable defibrillation threshold was detected. Indian Heart Rhythm Society 2009-01-07 /pmc/articles/PMC2615065/ /pubmed/19165362 Text en Copyright: © 2009 Margos et al. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Margos, Panagiotis N Schomburg, Rolf Kynast, Jorg Khattab, Ahmed A Richardt, Gert Termination of Ventricular Tachycardia with Antitachycardia Pacing after Ineffective Shock Therapy in an ICD Recipient with Hypertrophic Cardiomyopathy |
title | Termination of Ventricular Tachycardia with Antitachycardia Pacing after Ineffective Shock Therapy in an ICD Recipient with Hypertrophic Cardiomyopathy |
title_full | Termination of Ventricular Tachycardia with Antitachycardia Pacing after Ineffective Shock Therapy in an ICD Recipient with Hypertrophic Cardiomyopathy |
title_fullStr | Termination of Ventricular Tachycardia with Antitachycardia Pacing after Ineffective Shock Therapy in an ICD Recipient with Hypertrophic Cardiomyopathy |
title_full_unstemmed | Termination of Ventricular Tachycardia with Antitachycardia Pacing after Ineffective Shock Therapy in an ICD Recipient with Hypertrophic Cardiomyopathy |
title_short | Termination of Ventricular Tachycardia with Antitachycardia Pacing after Ineffective Shock Therapy in an ICD Recipient with Hypertrophic Cardiomyopathy |
title_sort | termination of ventricular tachycardia with antitachycardia pacing after ineffective shock therapy in an icd recipient with hypertrophic cardiomyopathy |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2615065/ https://www.ncbi.nlm.nih.gov/pubmed/19165362 |
work_keys_str_mv | AT margospanagiotisn terminationofventriculartachycardiawithantitachycardiapacingafterineffectiveshocktherapyinanicdrecipientwithhypertrophiccardiomyopathy AT schomburgrolf terminationofventriculartachycardiawithantitachycardiapacingafterineffectiveshocktherapyinanicdrecipientwithhypertrophiccardiomyopathy AT kynastjorg terminationofventriculartachycardiawithantitachycardiapacingafterineffectiveshocktherapyinanicdrecipientwithhypertrophiccardiomyopathy AT khattabahmeda terminationofventriculartachycardiawithantitachycardiapacingafterineffectiveshocktherapyinanicdrecipientwithhypertrophiccardiomyopathy AT richardtgert terminationofventriculartachycardiawithantitachycardiapacingafterineffectiveshocktherapyinanicdrecipientwithhypertrophiccardiomyopathy |