Cargando…

Redo aortic valve replacement after partial upper sternotomy (hemisternotomy) in a patient with idiopathic thrombocytopenia: a case report

BACKGROUND: We present a case of redo aortic valve replacement in a patient with thrombocytopenia. The initial operation was performed through limited access transverse sternotomy. This is the first report of this kind in the literature. CASE PRESENTATION: A 62 year old Caucasian male farmer with th...

Descripción completa

Detalles Bibliográficos
Autores principales: Fatayer, Hiba, Griffin, Steven, Protopapas, Aristotle D
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2621136/
https://www.ncbi.nlm.nih.gov/pubmed/19114015
http://dx.doi.org/10.1186/1757-1626-1-422
_version_ 1782163375002746880
author Fatayer, Hiba
Griffin, Steven
Protopapas, Aristotle D
author_facet Fatayer, Hiba
Griffin, Steven
Protopapas, Aristotle D
author_sort Fatayer, Hiba
collection PubMed
description BACKGROUND: We present a case of redo aortic valve replacement in a patient with thrombocytopenia. The initial operation was performed through limited access transverse sternotomy. This is the first report of this kind in the literature. CASE PRESENTATION: A 62 year old Caucasian male farmer with thrombocytopenia had uneventful redo aortic valve replacement when the first xenograft failed after 9 years, the transverse upper hemisternotomy in the first operation appearing to facilitate the redo complete sternotomy. CONCLUSION: With this only case of redo aortic valve replacement in our practice of 90 hemisternotomies over 10 years we present for consideration the use of a tissue valve in a complex relatively young patient.
format Text
id pubmed-2621136
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-26211362009-01-13 Redo aortic valve replacement after partial upper sternotomy (hemisternotomy) in a patient with idiopathic thrombocytopenia: a case report Fatayer, Hiba Griffin, Steven Protopapas, Aristotle D Cases J Case Report BACKGROUND: We present a case of redo aortic valve replacement in a patient with thrombocytopenia. The initial operation was performed through limited access transverse sternotomy. This is the first report of this kind in the literature. CASE PRESENTATION: A 62 year old Caucasian male farmer with thrombocytopenia had uneventful redo aortic valve replacement when the first xenograft failed after 9 years, the transverse upper hemisternotomy in the first operation appearing to facilitate the redo complete sternotomy. CONCLUSION: With this only case of redo aortic valve replacement in our practice of 90 hemisternotomies over 10 years we present for consideration the use of a tissue valve in a complex relatively young patient. BioMed Central 2008-12-29 /pmc/articles/PMC2621136/ /pubmed/19114015 http://dx.doi.org/10.1186/1757-1626-1-422 Text en Copyright © 2008 Fatayer et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Fatayer, Hiba
Griffin, Steven
Protopapas, Aristotle D
Redo aortic valve replacement after partial upper sternotomy (hemisternotomy) in a patient with idiopathic thrombocytopenia: a case report
title Redo aortic valve replacement after partial upper sternotomy (hemisternotomy) in a patient with idiopathic thrombocytopenia: a case report
title_full Redo aortic valve replacement after partial upper sternotomy (hemisternotomy) in a patient with idiopathic thrombocytopenia: a case report
title_fullStr Redo aortic valve replacement after partial upper sternotomy (hemisternotomy) in a patient with idiopathic thrombocytopenia: a case report
title_full_unstemmed Redo aortic valve replacement after partial upper sternotomy (hemisternotomy) in a patient with idiopathic thrombocytopenia: a case report
title_short Redo aortic valve replacement after partial upper sternotomy (hemisternotomy) in a patient with idiopathic thrombocytopenia: a case report
title_sort redo aortic valve replacement after partial upper sternotomy (hemisternotomy) in a patient with idiopathic thrombocytopenia: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2621136/
https://www.ncbi.nlm.nih.gov/pubmed/19114015
http://dx.doi.org/10.1186/1757-1626-1-422
work_keys_str_mv AT fatayerhiba redoaorticvalvereplacementafterpartialuppersternotomyhemisternotomyinapatientwithidiopathicthrombocytopeniaacasereport
AT griffinsteven redoaorticvalvereplacementafterpartialuppersternotomyhemisternotomyinapatientwithidiopathicthrombocytopeniaacasereport
AT protopapasaristotled redoaorticvalvereplacementafterpartialuppersternotomyhemisternotomyinapatientwithidiopathicthrombocytopeniaacasereport