Cargando…
A Meta-Analysis of the Accuracy of Prostate Cancer Studies Which Use Magnetic Resonance Spectroscopy as a Diagnostic Tool
OBJECTIVE: We aimed to do a meta-analysis of the existing literature to assess the accuracy of prostate cancer studies which use magnetic resonance spectroscopy (MRS) as a diagnostic tool. MATERIALS AND METHODS: Prospectively, independent, blind studies were selected from the Cochrane library, Pubme...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2627206/ https://www.ncbi.nlm.nih.gov/pubmed/18838853 http://dx.doi.org/10.3348/kjr.2008.9.5.432 |
_version_ | 1782163513824772096 |
---|---|
author | Wang, Peng Guo, You-min Liu, Min Qiang, Yong-qian Guo, Xiao-juan Zhang, Yi-li Duan, Xiao-Yi Zhang, Qiu-Juan Liang, Weifeng |
author_facet | Wang, Peng Guo, You-min Liu, Min Qiang, Yong-qian Guo, Xiao-juan Zhang, Yi-li Duan, Xiao-Yi Zhang, Qiu-Juan Liang, Weifeng |
author_sort | Wang, Peng |
collection | PubMed |
description | OBJECTIVE: We aimed to do a meta-analysis of the existing literature to assess the accuracy of prostate cancer studies which use magnetic resonance spectroscopy (MRS) as a diagnostic tool. MATERIALS AND METHODS: Prospectively, independent, blind studies were selected from the Cochrane library, Pubmed, and other network databases. The criteria for inclusion and exclusion in this study referenced the criteria of diagnostic research published by the Cochrane center. The statistical analysis was adopted by using Meta-Test version 6.0. Using the homogeneity test, a statistical effect model was chosen to calculate different pooled weighted values of sensitivity, specificity, and the corresponding 95% confidence intervals (95% CI). The summary receiver operating characteristic (SROC) curves method was used to assess the results. RESULTS: We chose two cut-off values (0.75 and 0.86) as the diagnostic criteria for discriminating between benign and malignant. In the first diagnostic criterion, the pooled weighted sensitivity, specificity, and corresponding 95% CI (expressed as area under curve [AUC]) were 0.82 (0.73, 0.89), 0.68 (0.58, 0.76), and 83.4% (74.97, 91.83). In the second criterion, the pooled weighted sensitivity, specificity, and corresponding 95% CI were 0.64 (0.55, 0.72), 0.86 (0.79, 0.91) and 82.7% (68.73, 96.68). CONCLUSION: As a new method in the diagnostic of prostate cancer, MRS has a better applied value compared to other common modalities. Ultimately, large scale RCT randomized controlled trial studies are necessary to assess its clinical value. |
format | Text |
id | pubmed-2627206 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2008 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-26272062009-02-17 A Meta-Analysis of the Accuracy of Prostate Cancer Studies Which Use Magnetic Resonance Spectroscopy as a Diagnostic Tool Wang, Peng Guo, You-min Liu, Min Qiang, Yong-qian Guo, Xiao-juan Zhang, Yi-li Duan, Xiao-Yi Zhang, Qiu-Juan Liang, Weifeng Korean J Radiol Original Article OBJECTIVE: We aimed to do a meta-analysis of the existing literature to assess the accuracy of prostate cancer studies which use magnetic resonance spectroscopy (MRS) as a diagnostic tool. MATERIALS AND METHODS: Prospectively, independent, blind studies were selected from the Cochrane library, Pubmed, and other network databases. The criteria for inclusion and exclusion in this study referenced the criteria of diagnostic research published by the Cochrane center. The statistical analysis was adopted by using Meta-Test version 6.0. Using the homogeneity test, a statistical effect model was chosen to calculate different pooled weighted values of sensitivity, specificity, and the corresponding 95% confidence intervals (95% CI). The summary receiver operating characteristic (SROC) curves method was used to assess the results. RESULTS: We chose two cut-off values (0.75 and 0.86) as the diagnostic criteria for discriminating between benign and malignant. In the first diagnostic criterion, the pooled weighted sensitivity, specificity, and corresponding 95% CI (expressed as area under curve [AUC]) were 0.82 (0.73, 0.89), 0.68 (0.58, 0.76), and 83.4% (74.97, 91.83). In the second criterion, the pooled weighted sensitivity, specificity, and corresponding 95% CI were 0.64 (0.55, 0.72), 0.86 (0.79, 0.91) and 82.7% (68.73, 96.68). CONCLUSION: As a new method in the diagnostic of prostate cancer, MRS has a better applied value compared to other common modalities. Ultimately, large scale RCT randomized controlled trial studies are necessary to assess its clinical value. The Korean Society of Radiology 2008 2008-10-30 /pmc/articles/PMC2627206/ /pubmed/18838853 http://dx.doi.org/10.3348/kjr.2008.9.5.432 Text en Copyright © 2008 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Wang, Peng Guo, You-min Liu, Min Qiang, Yong-qian Guo, Xiao-juan Zhang, Yi-li Duan, Xiao-Yi Zhang, Qiu-Juan Liang, Weifeng A Meta-Analysis of the Accuracy of Prostate Cancer Studies Which Use Magnetic Resonance Spectroscopy as a Diagnostic Tool |
title | A Meta-Analysis of the Accuracy of Prostate Cancer Studies Which Use Magnetic Resonance Spectroscopy as a Diagnostic Tool |
title_full | A Meta-Analysis of the Accuracy of Prostate Cancer Studies Which Use Magnetic Resonance Spectroscopy as a Diagnostic Tool |
title_fullStr | A Meta-Analysis of the Accuracy of Prostate Cancer Studies Which Use Magnetic Resonance Spectroscopy as a Diagnostic Tool |
title_full_unstemmed | A Meta-Analysis of the Accuracy of Prostate Cancer Studies Which Use Magnetic Resonance Spectroscopy as a Diagnostic Tool |
title_short | A Meta-Analysis of the Accuracy of Prostate Cancer Studies Which Use Magnetic Resonance Spectroscopy as a Diagnostic Tool |
title_sort | meta-analysis of the accuracy of prostate cancer studies which use magnetic resonance spectroscopy as a diagnostic tool |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2627206/ https://www.ncbi.nlm.nih.gov/pubmed/18838853 http://dx.doi.org/10.3348/kjr.2008.9.5.432 |
work_keys_str_mv | AT wangpeng ametaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool AT guoyoumin ametaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool AT liumin ametaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool AT qiangyongqian ametaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool AT guoxiaojuan ametaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool AT zhangyili ametaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool AT duanxiaoyi ametaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool AT zhangqiujuan ametaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool AT liangweifeng ametaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool AT wangpeng metaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool AT guoyoumin metaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool AT liumin metaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool AT qiangyongqian metaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool AT guoxiaojuan metaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool AT zhangyili metaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool AT duanxiaoyi metaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool AT zhangqiujuan metaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool AT liangweifeng metaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool |