Cargando…

A Meta-Analysis of the Accuracy of Prostate Cancer Studies Which Use Magnetic Resonance Spectroscopy as a Diagnostic Tool

OBJECTIVE: We aimed to do a meta-analysis of the existing literature to assess the accuracy of prostate cancer studies which use magnetic resonance spectroscopy (MRS) as a diagnostic tool. MATERIALS AND METHODS: Prospectively, independent, blind studies were selected from the Cochrane library, Pubme...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Peng, Guo, You-min, Liu, Min, Qiang, Yong-qian, Guo, Xiao-juan, Zhang, Yi-li, Duan, Xiao-Yi, Zhang, Qiu-Juan, Liang, Weifeng
Formato: Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2627206/
https://www.ncbi.nlm.nih.gov/pubmed/18838853
http://dx.doi.org/10.3348/kjr.2008.9.5.432
_version_ 1782163513824772096
author Wang, Peng
Guo, You-min
Liu, Min
Qiang, Yong-qian
Guo, Xiao-juan
Zhang, Yi-li
Duan, Xiao-Yi
Zhang, Qiu-Juan
Liang, Weifeng
author_facet Wang, Peng
Guo, You-min
Liu, Min
Qiang, Yong-qian
Guo, Xiao-juan
Zhang, Yi-li
Duan, Xiao-Yi
Zhang, Qiu-Juan
Liang, Weifeng
author_sort Wang, Peng
collection PubMed
description OBJECTIVE: We aimed to do a meta-analysis of the existing literature to assess the accuracy of prostate cancer studies which use magnetic resonance spectroscopy (MRS) as a diagnostic tool. MATERIALS AND METHODS: Prospectively, independent, blind studies were selected from the Cochrane library, Pubmed, and other network databases. The criteria for inclusion and exclusion in this study referenced the criteria of diagnostic research published by the Cochrane center. The statistical analysis was adopted by using Meta-Test version 6.0. Using the homogeneity test, a statistical effect model was chosen to calculate different pooled weighted values of sensitivity, specificity, and the corresponding 95% confidence intervals (95% CI). The summary receiver operating characteristic (SROC) curves method was used to assess the results. RESULTS: We chose two cut-off values (0.75 and 0.86) as the diagnostic criteria for discriminating between benign and malignant. In the first diagnostic criterion, the pooled weighted sensitivity, specificity, and corresponding 95% CI (expressed as area under curve [AUC]) were 0.82 (0.73, 0.89), 0.68 (0.58, 0.76), and 83.4% (74.97, 91.83). In the second criterion, the pooled weighted sensitivity, specificity, and corresponding 95% CI were 0.64 (0.55, 0.72), 0.86 (0.79, 0.91) and 82.7% (68.73, 96.68). CONCLUSION: As a new method in the diagnostic of prostate cancer, MRS has a better applied value compared to other common modalities. Ultimately, large scale RCT randomized controlled trial studies are necessary to assess its clinical value.
format Text
id pubmed-2627206
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-26272062009-02-17 A Meta-Analysis of the Accuracy of Prostate Cancer Studies Which Use Magnetic Resonance Spectroscopy as a Diagnostic Tool Wang, Peng Guo, You-min Liu, Min Qiang, Yong-qian Guo, Xiao-juan Zhang, Yi-li Duan, Xiao-Yi Zhang, Qiu-Juan Liang, Weifeng Korean J Radiol Original Article OBJECTIVE: We aimed to do a meta-analysis of the existing literature to assess the accuracy of prostate cancer studies which use magnetic resonance spectroscopy (MRS) as a diagnostic tool. MATERIALS AND METHODS: Prospectively, independent, blind studies were selected from the Cochrane library, Pubmed, and other network databases. The criteria for inclusion and exclusion in this study referenced the criteria of diagnostic research published by the Cochrane center. The statistical analysis was adopted by using Meta-Test version 6.0. Using the homogeneity test, a statistical effect model was chosen to calculate different pooled weighted values of sensitivity, specificity, and the corresponding 95% confidence intervals (95% CI). The summary receiver operating characteristic (SROC) curves method was used to assess the results. RESULTS: We chose two cut-off values (0.75 and 0.86) as the diagnostic criteria for discriminating between benign and malignant. In the first diagnostic criterion, the pooled weighted sensitivity, specificity, and corresponding 95% CI (expressed as area under curve [AUC]) were 0.82 (0.73, 0.89), 0.68 (0.58, 0.76), and 83.4% (74.97, 91.83). In the second criterion, the pooled weighted sensitivity, specificity, and corresponding 95% CI were 0.64 (0.55, 0.72), 0.86 (0.79, 0.91) and 82.7% (68.73, 96.68). CONCLUSION: As a new method in the diagnostic of prostate cancer, MRS has a better applied value compared to other common modalities. Ultimately, large scale RCT randomized controlled trial studies are necessary to assess its clinical value. The Korean Society of Radiology 2008 2008-10-30 /pmc/articles/PMC2627206/ /pubmed/18838853 http://dx.doi.org/10.3348/kjr.2008.9.5.432 Text en Copyright © 2008 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Wang, Peng
Guo, You-min
Liu, Min
Qiang, Yong-qian
Guo, Xiao-juan
Zhang, Yi-li
Duan, Xiao-Yi
Zhang, Qiu-Juan
Liang, Weifeng
A Meta-Analysis of the Accuracy of Prostate Cancer Studies Which Use Magnetic Resonance Spectroscopy as a Diagnostic Tool
title A Meta-Analysis of the Accuracy of Prostate Cancer Studies Which Use Magnetic Resonance Spectroscopy as a Diagnostic Tool
title_full A Meta-Analysis of the Accuracy of Prostate Cancer Studies Which Use Magnetic Resonance Spectroscopy as a Diagnostic Tool
title_fullStr A Meta-Analysis of the Accuracy of Prostate Cancer Studies Which Use Magnetic Resonance Spectroscopy as a Diagnostic Tool
title_full_unstemmed A Meta-Analysis of the Accuracy of Prostate Cancer Studies Which Use Magnetic Resonance Spectroscopy as a Diagnostic Tool
title_short A Meta-Analysis of the Accuracy of Prostate Cancer Studies Which Use Magnetic Resonance Spectroscopy as a Diagnostic Tool
title_sort meta-analysis of the accuracy of prostate cancer studies which use magnetic resonance spectroscopy as a diagnostic tool
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2627206/
https://www.ncbi.nlm.nih.gov/pubmed/18838853
http://dx.doi.org/10.3348/kjr.2008.9.5.432
work_keys_str_mv AT wangpeng ametaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool
AT guoyoumin ametaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool
AT liumin ametaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool
AT qiangyongqian ametaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool
AT guoxiaojuan ametaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool
AT zhangyili ametaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool
AT duanxiaoyi ametaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool
AT zhangqiujuan ametaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool
AT liangweifeng ametaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool
AT wangpeng metaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool
AT guoyoumin metaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool
AT liumin metaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool
AT qiangyongqian metaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool
AT guoxiaojuan metaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool
AT zhangyili metaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool
AT duanxiaoyi metaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool
AT zhangqiujuan metaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool
AT liangweifeng metaanalysisoftheaccuracyofprostatecancerstudieswhichusemagneticresonancespectroscopyasadiagnostictool