Cargando…
Semi-Automatic Measurement of the Airway Dimension by Computed Tomography Using the Full-With-Half-Maximum Method: a Study of the Measurement Accuracy according to the Orientation of an Artificial Airway
OBJECTIVE: To develop an algorithm to measure the dimensions of an airway oriented obliquely on a volumetric CT, as well as assess the effect of the imaging parameters on the correct measurement of the airway dimension. MATERIALS AND METHODS: An airway phantom with 11 poly-acryl tubes of various lum...
Autores principales: | , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
The Korean Radiological Society
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2627256/ https://www.ncbi.nlm.nih.gov/pubmed/18525226 http://dx.doi.org/10.3348/kjr.2008.9.3.236 |
_version_ | 1782163527791804416 |
---|---|
author | Kim, Namkug Seo, Joon Beom Song, Koun-Sik Chae, Eun Jin Kang, Suk-Ho |
author_facet | Kim, Namkug Seo, Joon Beom Song, Koun-Sik Chae, Eun Jin Kang, Suk-Ho |
author_sort | Kim, Namkug |
collection | PubMed |
description | OBJECTIVE: To develop an algorithm to measure the dimensions of an airway oriented obliquely on a volumetric CT, as well as assess the effect of the imaging parameters on the correct measurement of the airway dimension. MATERIALS AND METHODS: An airway phantom with 11 poly-acryl tubes of various lumen diameters and wall thicknesses was scanned using a 16-MDCT (multidetector CT) at various tilt angles (0, 30, 45, and 60°). The CT images were reconstructed at various reconstruction kernels and thicknesses. The axis of each airway was determined using the 3D thinning algorithm, with images perpendicular to the axis being reconstructed. The luminal radius and wall thickness was measured by the full-width-half-maximum method. The influence of the CT parameters (the size of the airways, obliquity on the radius and wall thickness) was assessed by comparing the actual dimension of each tube with the estimated values. RESULTS: The 3D thinning algorithm correctly determined the axis of the oblique airway in all tubes (mean error: 0.91 ± 0.82°). A sharper reconstruction kernel, thicker image thickness and larger tilt angle of the airway axis resulted in a significant decrease of the measured wall thickness and an increase of the measured luminal radius. Use of a standard kernel and a 0.75-mm slice thickness resulted in the most accurate measurement of airway dimension, which was independent of obliquity. CONCLUSION: The airway obliquity and imaging parameters have a strong influence on the accuracy of the airway wall measurement. For the accurate measurement of airway thickness, the CT images should be reconstructed with a standard kernel and a 0.75 mm slice thickness. |
format | Text |
id | pubmed-2627256 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2008 |
publisher | The Korean Radiological Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-26272562009-02-17 Semi-Automatic Measurement of the Airway Dimension by Computed Tomography Using the Full-With-Half-Maximum Method: a Study of the Measurement Accuracy according to the Orientation of an Artificial Airway Kim, Namkug Seo, Joon Beom Song, Koun-Sik Chae, Eun Jin Kang, Suk-Ho Korean J Radiol Original Article OBJECTIVE: To develop an algorithm to measure the dimensions of an airway oriented obliquely on a volumetric CT, as well as assess the effect of the imaging parameters on the correct measurement of the airway dimension. MATERIALS AND METHODS: An airway phantom with 11 poly-acryl tubes of various lumen diameters and wall thicknesses was scanned using a 16-MDCT (multidetector CT) at various tilt angles (0, 30, 45, and 60°). The CT images were reconstructed at various reconstruction kernels and thicknesses. The axis of each airway was determined using the 3D thinning algorithm, with images perpendicular to the axis being reconstructed. The luminal radius and wall thickness was measured by the full-width-half-maximum method. The influence of the CT parameters (the size of the airways, obliquity on the radius and wall thickness) was assessed by comparing the actual dimension of each tube with the estimated values. RESULTS: The 3D thinning algorithm correctly determined the axis of the oblique airway in all tubes (mean error: 0.91 ± 0.82°). A sharper reconstruction kernel, thicker image thickness and larger tilt angle of the airway axis resulted in a significant decrease of the measured wall thickness and an increase of the measured luminal radius. Use of a standard kernel and a 0.75-mm slice thickness resulted in the most accurate measurement of airway dimension, which was independent of obliquity. CONCLUSION: The airway obliquity and imaging parameters have a strong influence on the accuracy of the airway wall measurement. For the accurate measurement of airway thickness, the CT images should be reconstructed with a standard kernel and a 0.75 mm slice thickness. The Korean Radiological Society 2008 2008-06-20 /pmc/articles/PMC2627256/ /pubmed/18525226 http://dx.doi.org/10.3348/kjr.2008.9.3.236 Text en Copyright © 2008 The Korean Radiological Society http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Kim, Namkug Seo, Joon Beom Song, Koun-Sik Chae, Eun Jin Kang, Suk-Ho Semi-Automatic Measurement of the Airway Dimension by Computed Tomography Using the Full-With-Half-Maximum Method: a Study of the Measurement Accuracy according to the Orientation of an Artificial Airway |
title | Semi-Automatic Measurement of the Airway Dimension by Computed Tomography Using the Full-With-Half-Maximum Method: a Study of the Measurement Accuracy according to the Orientation of an Artificial Airway |
title_full | Semi-Automatic Measurement of the Airway Dimension by Computed Tomography Using the Full-With-Half-Maximum Method: a Study of the Measurement Accuracy according to the Orientation of an Artificial Airway |
title_fullStr | Semi-Automatic Measurement of the Airway Dimension by Computed Tomography Using the Full-With-Half-Maximum Method: a Study of the Measurement Accuracy according to the Orientation of an Artificial Airway |
title_full_unstemmed | Semi-Automatic Measurement of the Airway Dimension by Computed Tomography Using the Full-With-Half-Maximum Method: a Study of the Measurement Accuracy according to the Orientation of an Artificial Airway |
title_short | Semi-Automatic Measurement of the Airway Dimension by Computed Tomography Using the Full-With-Half-Maximum Method: a Study of the Measurement Accuracy according to the Orientation of an Artificial Airway |
title_sort | semi-automatic measurement of the airway dimension by computed tomography using the full-with-half-maximum method: a study of the measurement accuracy according to the orientation of an artificial airway |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2627256/ https://www.ncbi.nlm.nih.gov/pubmed/18525226 http://dx.doi.org/10.3348/kjr.2008.9.3.236 |
work_keys_str_mv | AT kimnamkug semiautomaticmeasurementoftheairwaydimensionbycomputedtomographyusingthefullwithhalfmaximummethodastudyofthemeasurementaccuracyaccordingtotheorientationofanartificialairway AT seojoonbeom semiautomaticmeasurementoftheairwaydimensionbycomputedtomographyusingthefullwithhalfmaximummethodastudyofthemeasurementaccuracyaccordingtotheorientationofanartificialairway AT songkounsik semiautomaticmeasurementoftheairwaydimensionbycomputedtomographyusingthefullwithhalfmaximummethodastudyofthemeasurementaccuracyaccordingtotheorientationofanartificialairway AT chaeeunjin semiautomaticmeasurementoftheairwaydimensionbycomputedtomographyusingthefullwithhalfmaximummethodastudyofthemeasurementaccuracyaccordingtotheorientationofanartificialairway AT kangsukho semiautomaticmeasurementoftheairwaydimensionbycomputedtomographyusingthefullwithhalfmaximummethodastudyofthemeasurementaccuracyaccordingtotheorientationofanartificialairway |