Cargando…

Pericardium Plug in the Repair of the Corneoscleral Fistula After Ahmed Glaucoma Valve Explantation

We report four cases in which a pericardium (Tutoplast®) plug was used to repair a corneoscleral fistula after Ahmed Glaucoma Valve (AGV) explantation. In four cases in which the AGV tube had been exposed, AGV explantation was performed using a pericardium (Tutoplast®) plug to seal the defect previo...

Descripción completa

Detalles Bibliográficos
Autores principales: Yoo, Chungkwon, Kwon, Sung Wook, Kim, Yong Yeon
Formato: Texto
Lenguaje:English
Publicado: The Korean Ophthalmological Society 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2629908/
https://www.ncbi.nlm.nih.gov/pubmed/19096247
http://dx.doi.org/10.3341/kjo.2008.22.4.268
_version_ 1782163821319684096
author Yoo, Chungkwon
Kwon, Sung Wook
Kim, Yong Yeon
author_facet Yoo, Chungkwon
Kwon, Sung Wook
Kim, Yong Yeon
author_sort Yoo, Chungkwon
collection PubMed
description We report four cases in which a pericardium (Tutoplast®) plug was used to repair a corneoscleral fistula after Ahmed Glaucoma Valve (AGV) explantation. In four cases in which the AGV tube had been exposed, AGV explantation was performed using a pericardium (Tutoplast®) plug to seal the defect previously occupied by the tube. After debridement of the fistula, a piece of processed pericardium (Tutoplast®), measured 1 mm in width, was plugged into the fistula and secured with two interrupted 10-0 nylon sutures. To control intraocular pressure, a new AGV was implanted elsewhere in case 1, phaco-trabeculectomy was performed concurrently in case 2, cyclophotocoagulation was performed postoperatively in case 3 and anti-glaucomatous medication was added in case 4. No complication related to the fistula developed at the latest follow-up (range: 12~26 months). The pericardium (Tutoplast®) plug seems to be an effective method in the repair of corneoscleral fistulas resulting from explantation of glaucoma drainage implants.
format Text
id pubmed-2629908
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher The Korean Ophthalmological Society
record_format MEDLINE/PubMed
spelling pubmed-26299082009-02-25 Pericardium Plug in the Repair of the Corneoscleral Fistula After Ahmed Glaucoma Valve Explantation Yoo, Chungkwon Kwon, Sung Wook Kim, Yong Yeon Korean J Ophthalmol Case Report We report four cases in which a pericardium (Tutoplast®) plug was used to repair a corneoscleral fistula after Ahmed Glaucoma Valve (AGV) explantation. In four cases in which the AGV tube had been exposed, AGV explantation was performed using a pericardium (Tutoplast®) plug to seal the defect previously occupied by the tube. After debridement of the fistula, a piece of processed pericardium (Tutoplast®), measured 1 mm in width, was plugged into the fistula and secured with two interrupted 10-0 nylon sutures. To control intraocular pressure, a new AGV was implanted elsewhere in case 1, phaco-trabeculectomy was performed concurrently in case 2, cyclophotocoagulation was performed postoperatively in case 3 and anti-glaucomatous medication was added in case 4. No complication related to the fistula developed at the latest follow-up (range: 12~26 months). The pericardium (Tutoplast®) plug seems to be an effective method in the repair of corneoscleral fistulas resulting from explantation of glaucoma drainage implants. The Korean Ophthalmological Society 2008-12 2008-12-29 /pmc/articles/PMC2629908/ /pubmed/19096247 http://dx.doi.org/10.3341/kjo.2008.22.4.268 Text en Copyright © 2008 The Korean Ophthalmological Society http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Yoo, Chungkwon
Kwon, Sung Wook
Kim, Yong Yeon
Pericardium Plug in the Repair of the Corneoscleral Fistula After Ahmed Glaucoma Valve Explantation
title Pericardium Plug in the Repair of the Corneoscleral Fistula After Ahmed Glaucoma Valve Explantation
title_full Pericardium Plug in the Repair of the Corneoscleral Fistula After Ahmed Glaucoma Valve Explantation
title_fullStr Pericardium Plug in the Repair of the Corneoscleral Fistula After Ahmed Glaucoma Valve Explantation
title_full_unstemmed Pericardium Plug in the Repair of the Corneoscleral Fistula After Ahmed Glaucoma Valve Explantation
title_short Pericardium Plug in the Repair of the Corneoscleral Fistula After Ahmed Glaucoma Valve Explantation
title_sort pericardium plug in the repair of the corneoscleral fistula after ahmed glaucoma valve explantation
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2629908/
https://www.ncbi.nlm.nih.gov/pubmed/19096247
http://dx.doi.org/10.3341/kjo.2008.22.4.268
work_keys_str_mv AT yoochungkwon pericardiumplugintherepairofthecorneoscleralfistulaafterahmedglaucomavalveexplantation
AT kwonsungwook pericardiumplugintherepairofthecorneoscleralfistulaafterahmedglaucomavalveexplantation
AT kimyongyeon pericardiumplugintherepairofthecorneoscleralfistulaafterahmedglaucomavalveexplantation