Cargando…

Validation of a flow cytometry based chemokine internalization assay for use in evaluating the pharmacodynamic response to a receptor antagonist

Pharmacodynamic assays are important in clinical trial design to investigate the relationship between drug concentration (pharmacokinetics) and drug "effect' or biological activity. Increasingly flow cytometry is being used to examine the pharmacodynamic effect of new drug entities. Howeve...

Descripción completa

Detalles Bibliográficos
Autores principales: Wyant, Timothy, Lackey, Alan, Green, Marie
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2639553/
https://www.ncbi.nlm.nih.gov/pubmed/19046455
http://dx.doi.org/10.1186/1479-5876-6-76
_version_ 1782164473118720000
author Wyant, Timothy
Lackey, Alan
Green, Marie
author_facet Wyant, Timothy
Lackey, Alan
Green, Marie
author_sort Wyant, Timothy
collection PubMed
description Pharmacodynamic assays are important in clinical trial design to investigate the relationship between drug concentration (pharmacokinetics) and drug "effect' or biological activity. Increasingly flow cytometry is being used to examine the pharmacodynamic effect of new drug entities. However, to date, the analytical validation of cytometry based assays is limited and there is no suitable guidance for method validation of flow cytometry-based pharmacodynamic assays. Here we report the validation of a flow cytometry-based chemokine internalization assay for use in evaluating the effect of a receptor antagonist in clinical trials. The assay method was validated by examining the stability of the reagent, assay robustness, sensitivity, repeatability and reproducibility precision. Experimental results show the assay reagent was stable over 26 weeks. The assay demonstrated a sensitivity to distinguish 0.005 μg/ml of a CCR2 antagonist with a %CV of 13.3%. The intra-assay repeatability was less than 15% with an inter-assay repeatability of less than 20%. In vivo study results demonstrated that the assay was consistent and a reliable measure of antagonist activity.
format Text
id pubmed-2639553
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-26395532009-02-11 Validation of a flow cytometry based chemokine internalization assay for use in evaluating the pharmacodynamic response to a receptor antagonist Wyant, Timothy Lackey, Alan Green, Marie J Transl Med Methodology Pharmacodynamic assays are important in clinical trial design to investigate the relationship between drug concentration (pharmacokinetics) and drug "effect' or biological activity. Increasingly flow cytometry is being used to examine the pharmacodynamic effect of new drug entities. However, to date, the analytical validation of cytometry based assays is limited and there is no suitable guidance for method validation of flow cytometry-based pharmacodynamic assays. Here we report the validation of a flow cytometry-based chemokine internalization assay for use in evaluating the effect of a receptor antagonist in clinical trials. The assay method was validated by examining the stability of the reagent, assay robustness, sensitivity, repeatability and reproducibility precision. Experimental results show the assay reagent was stable over 26 weeks. The assay demonstrated a sensitivity to distinguish 0.005 μg/ml of a CCR2 antagonist with a %CV of 13.3%. The intra-assay repeatability was less than 15% with an inter-assay repeatability of less than 20%. In vivo study results demonstrated that the assay was consistent and a reliable measure of antagonist activity. BioMed Central 2008-12-01 /pmc/articles/PMC2639553/ /pubmed/19046455 http://dx.doi.org/10.1186/1479-5876-6-76 Text en Copyright © 2008 Wyant et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Methodology
Wyant, Timothy
Lackey, Alan
Green, Marie
Validation of a flow cytometry based chemokine internalization assay for use in evaluating the pharmacodynamic response to a receptor antagonist
title Validation of a flow cytometry based chemokine internalization assay for use in evaluating the pharmacodynamic response to a receptor antagonist
title_full Validation of a flow cytometry based chemokine internalization assay for use in evaluating the pharmacodynamic response to a receptor antagonist
title_fullStr Validation of a flow cytometry based chemokine internalization assay for use in evaluating the pharmacodynamic response to a receptor antagonist
title_full_unstemmed Validation of a flow cytometry based chemokine internalization assay for use in evaluating the pharmacodynamic response to a receptor antagonist
title_short Validation of a flow cytometry based chemokine internalization assay for use in evaluating the pharmacodynamic response to a receptor antagonist
title_sort validation of a flow cytometry based chemokine internalization assay for use in evaluating the pharmacodynamic response to a receptor antagonist
topic Methodology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2639553/
https://www.ncbi.nlm.nih.gov/pubmed/19046455
http://dx.doi.org/10.1186/1479-5876-6-76
work_keys_str_mv AT wyanttimothy validationofaflowcytometrybasedchemokineinternalizationassayforuseinevaluatingthepharmacodynamicresponsetoareceptorantagonist
AT lackeyalan validationofaflowcytometrybasedchemokineinternalizationassayforuseinevaluatingthepharmacodynamicresponsetoareceptorantagonist
AT greenmarie validationofaflowcytometrybasedchemokineinternalizationassayforuseinevaluatingthepharmacodynamicresponsetoareceptorantagonist