Cargando…
Validation of a flow cytometry based chemokine internalization assay for use in evaluating the pharmacodynamic response to a receptor antagonist
Pharmacodynamic assays are important in clinical trial design to investigate the relationship between drug concentration (pharmacokinetics) and drug "effect' or biological activity. Increasingly flow cytometry is being used to examine the pharmacodynamic effect of new drug entities. Howeve...
Autores principales: | , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2639553/ https://www.ncbi.nlm.nih.gov/pubmed/19046455 http://dx.doi.org/10.1186/1479-5876-6-76 |
_version_ | 1782164473118720000 |
---|---|
author | Wyant, Timothy Lackey, Alan Green, Marie |
author_facet | Wyant, Timothy Lackey, Alan Green, Marie |
author_sort | Wyant, Timothy |
collection | PubMed |
description | Pharmacodynamic assays are important in clinical trial design to investigate the relationship between drug concentration (pharmacokinetics) and drug "effect' or biological activity. Increasingly flow cytometry is being used to examine the pharmacodynamic effect of new drug entities. However, to date, the analytical validation of cytometry based assays is limited and there is no suitable guidance for method validation of flow cytometry-based pharmacodynamic assays. Here we report the validation of a flow cytometry-based chemokine internalization assay for use in evaluating the effect of a receptor antagonist in clinical trials. The assay method was validated by examining the stability of the reagent, assay robustness, sensitivity, repeatability and reproducibility precision. Experimental results show the assay reagent was stable over 26 weeks. The assay demonstrated a sensitivity to distinguish 0.005 μg/ml of a CCR2 antagonist with a %CV of 13.3%. The intra-assay repeatability was less than 15% with an inter-assay repeatability of less than 20%. In vivo study results demonstrated that the assay was consistent and a reliable measure of antagonist activity. |
format | Text |
id | pubmed-2639553 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2008 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-26395532009-02-11 Validation of a flow cytometry based chemokine internalization assay for use in evaluating the pharmacodynamic response to a receptor antagonist Wyant, Timothy Lackey, Alan Green, Marie J Transl Med Methodology Pharmacodynamic assays are important in clinical trial design to investigate the relationship between drug concentration (pharmacokinetics) and drug "effect' or biological activity. Increasingly flow cytometry is being used to examine the pharmacodynamic effect of new drug entities. However, to date, the analytical validation of cytometry based assays is limited and there is no suitable guidance for method validation of flow cytometry-based pharmacodynamic assays. Here we report the validation of a flow cytometry-based chemokine internalization assay for use in evaluating the effect of a receptor antagonist in clinical trials. The assay method was validated by examining the stability of the reagent, assay robustness, sensitivity, repeatability and reproducibility precision. Experimental results show the assay reagent was stable over 26 weeks. The assay demonstrated a sensitivity to distinguish 0.005 μg/ml of a CCR2 antagonist with a %CV of 13.3%. The intra-assay repeatability was less than 15% with an inter-assay repeatability of less than 20%. In vivo study results demonstrated that the assay was consistent and a reliable measure of antagonist activity. BioMed Central 2008-12-01 /pmc/articles/PMC2639553/ /pubmed/19046455 http://dx.doi.org/10.1186/1479-5876-6-76 Text en Copyright © 2008 Wyant et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Methodology Wyant, Timothy Lackey, Alan Green, Marie Validation of a flow cytometry based chemokine internalization assay for use in evaluating the pharmacodynamic response to a receptor antagonist |
title | Validation of a flow cytometry based chemokine internalization assay for use in evaluating the pharmacodynamic response to a receptor antagonist |
title_full | Validation of a flow cytometry based chemokine internalization assay for use in evaluating the pharmacodynamic response to a receptor antagonist |
title_fullStr | Validation of a flow cytometry based chemokine internalization assay for use in evaluating the pharmacodynamic response to a receptor antagonist |
title_full_unstemmed | Validation of a flow cytometry based chemokine internalization assay for use in evaluating the pharmacodynamic response to a receptor antagonist |
title_short | Validation of a flow cytometry based chemokine internalization assay for use in evaluating the pharmacodynamic response to a receptor antagonist |
title_sort | validation of a flow cytometry based chemokine internalization assay for use in evaluating the pharmacodynamic response to a receptor antagonist |
topic | Methodology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2639553/ https://www.ncbi.nlm.nih.gov/pubmed/19046455 http://dx.doi.org/10.1186/1479-5876-6-76 |
work_keys_str_mv | AT wyanttimothy validationofaflowcytometrybasedchemokineinternalizationassayforuseinevaluatingthepharmacodynamicresponsetoareceptorantagonist AT lackeyalan validationofaflowcytometrybasedchemokineinternalizationassayforuseinevaluatingthepharmacodynamicresponsetoareceptorantagonist AT greenmarie validationofaflowcytometrybasedchemokineinternalizationassayforuseinevaluatingthepharmacodynamicresponsetoareceptorantagonist |