Improved Focalization of Electrical Microstimulation Using Microelectrode Arrays: A Modeling Study
Extracellular electrical stimulation (EES) of the central nervous system (CNS) has been used empirically for decades, with both fundamental and clinical goals. Currently, microelectrode arrays (MEAs) offer new possibilities for CNS microstimulation. However, although focal CNS activation is of criti...
Autores principales: | , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2652101/ https://www.ncbi.nlm.nih.gov/pubmed/19279677 http://dx.doi.org/10.1371/journal.pone.0004828 |
_version_ | 1782165221275598848 |
---|---|
author | Joucla, Sébastien Yvert, Blaise |
author_facet | Joucla, Sébastien Yvert, Blaise |
author_sort | Joucla, Sébastien |
collection | PubMed |
description | Extracellular electrical stimulation (EES) of the central nervous system (CNS) has been used empirically for decades, with both fundamental and clinical goals. Currently, microelectrode arrays (MEAs) offer new possibilities for CNS microstimulation. However, although focal CNS activation is of critical importance to achieve efficient stimulation strategies, the precise spatial extent of EES remains poorly understood. The aim of the present work is twofold. First, we validate a finite element model to compute accurately the electrical potential field generated throughout the extracellular medium by an EES delivered with MEAs. This model uses Robin boundary conditions that take into account the surface conductance of electrode/medium interfaces. Using this model, we determine how the potential field is influenced by the stimulation and ground electrode impedances, and by the electrical conductivity of the neural tissue. We confirm that current-controlled stimulations should be preferred to voltage-controlled stimulations in order to control the amplitude of the potential field. Second, we evaluate the focality of the potential field and threshold-distance curves for different electrode configurations. We propose a new configuration to improve the focality, using a ground surface surrounding all the electrodes of the array. We show that the lower the impedance of this surface, the more focal the stimulation. In conclusion, this study proposes new boundary conditions for the design of precise computational models of extracellular stimulation, and a new electrode configuration that can be easily incorporated into future MEA devices, either in vitro or in vivo, for a better spatial control of CNS microstimulation. |
format | Text |
id | pubmed-2652101 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-26521012009-03-12 Improved Focalization of Electrical Microstimulation Using Microelectrode Arrays: A Modeling Study Joucla, Sébastien Yvert, Blaise PLoS One Research Article Extracellular electrical stimulation (EES) of the central nervous system (CNS) has been used empirically for decades, with both fundamental and clinical goals. Currently, microelectrode arrays (MEAs) offer new possibilities for CNS microstimulation. However, although focal CNS activation is of critical importance to achieve efficient stimulation strategies, the precise spatial extent of EES remains poorly understood. The aim of the present work is twofold. First, we validate a finite element model to compute accurately the electrical potential field generated throughout the extracellular medium by an EES delivered with MEAs. This model uses Robin boundary conditions that take into account the surface conductance of electrode/medium interfaces. Using this model, we determine how the potential field is influenced by the stimulation and ground electrode impedances, and by the electrical conductivity of the neural tissue. We confirm that current-controlled stimulations should be preferred to voltage-controlled stimulations in order to control the amplitude of the potential field. Second, we evaluate the focality of the potential field and threshold-distance curves for different electrode configurations. We propose a new configuration to improve the focality, using a ground surface surrounding all the electrodes of the array. We show that the lower the impedance of this surface, the more focal the stimulation. In conclusion, this study proposes new boundary conditions for the design of precise computational models of extracellular stimulation, and a new electrode configuration that can be easily incorporated into future MEA devices, either in vitro or in vivo, for a better spatial control of CNS microstimulation. Public Library of Science 2009-03-12 /pmc/articles/PMC2652101/ /pubmed/19279677 http://dx.doi.org/10.1371/journal.pone.0004828 Text en Joucla et al. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Joucla, Sébastien Yvert, Blaise Improved Focalization of Electrical Microstimulation Using Microelectrode Arrays: A Modeling Study |
title | Improved Focalization of Electrical Microstimulation Using Microelectrode Arrays: A Modeling Study |
title_full | Improved Focalization of Electrical Microstimulation Using Microelectrode Arrays: A Modeling Study |
title_fullStr | Improved Focalization of Electrical Microstimulation Using Microelectrode Arrays: A Modeling Study |
title_full_unstemmed | Improved Focalization of Electrical Microstimulation Using Microelectrode Arrays: A Modeling Study |
title_short | Improved Focalization of Electrical Microstimulation Using Microelectrode Arrays: A Modeling Study |
title_sort | improved focalization of electrical microstimulation using microelectrode arrays: a modeling study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2652101/ https://www.ncbi.nlm.nih.gov/pubmed/19279677 http://dx.doi.org/10.1371/journal.pone.0004828 |
work_keys_str_mv | AT jouclasebastien improvedfocalizationofelectricalmicrostimulationusingmicroelectrodearraysamodelingstudy AT yvertblaise improvedfocalizationofelectricalmicrostimulationusingmicroelectrodearraysamodelingstudy |