Cargando…

New technologies to reduce pediatric radiation doses

X-ray dose reduction in pediatrics is particularly important because babies and children are very sensitive to radiation exposure. We present new developments to further decrease pediatric patient dose. With the help of an advanced exposure control, a constant image quality can be maintained for all...

Descripción completa

Detalles Bibliográficos
Autores principales: Bernhardt, Philipp, Lendl, Markus, Deinzer, Frank
Formato: Texto
Lenguaje:English
Publicado: Springer-Verlag 2006
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2663645/
https://www.ncbi.nlm.nih.gov/pubmed/16862409
http://dx.doi.org/10.1007/s00247-006-0212-4
_version_ 1782165912850268160
author Bernhardt, Philipp
Lendl, Markus
Deinzer, Frank
author_facet Bernhardt, Philipp
Lendl, Markus
Deinzer, Frank
author_sort Bernhardt, Philipp
collection PubMed
description X-ray dose reduction in pediatrics is particularly important because babies and children are very sensitive to radiation exposure. We present new developments to further decrease pediatric patient dose. With the help of an advanced exposure control, a constant image quality can be maintained for all patient sizes, leading to dose savings for babies and children of up to 30%. Because objects of interest are quite small and the speed of motion is high in pediatric patients, short pulse widths down to 4 ms are important to reduce motion blurring artifacts. Further, a new noise-reduction algorithm is presented that detects and processes signal and noise in different frequency bands, generating smooth images without contrast loss. Finally, we introduce a super-resolution technique: two or more medical images, which are shifted against each other in a subpixel region, are combined to resolve structures smaller than the size of a single pixel. Advanced exposure control, short exposure times, noise reduction and super-resolution provide improved image quality, which can also be invested to save radiation exposure. All in all, the tools presented here offer a large potential to minimize the deterministic and stochastic risks of radiation exposure.
format Text
id pubmed-2663645
institution National Center for Biotechnology Information
language English
publishDate 2006
publisher Springer-Verlag
record_format MEDLINE/PubMed
spelling pubmed-26636452009-04-23 New technologies to reduce pediatric radiation doses Bernhardt, Philipp Lendl, Markus Deinzer, Frank Pediatr Radiol Alara X-ray dose reduction in pediatrics is particularly important because babies and children are very sensitive to radiation exposure. We present new developments to further decrease pediatric patient dose. With the help of an advanced exposure control, a constant image quality can be maintained for all patient sizes, leading to dose savings for babies and children of up to 30%. Because objects of interest are quite small and the speed of motion is high in pediatric patients, short pulse widths down to 4 ms are important to reduce motion blurring artifacts. Further, a new noise-reduction algorithm is presented that detects and processes signal and noise in different frequency bands, generating smooth images without contrast loss. Finally, we introduce a super-resolution technique: two or more medical images, which are shifted against each other in a subpixel region, are combined to resolve structures smaller than the size of a single pixel. Advanced exposure control, short exposure times, noise reduction and super-resolution provide improved image quality, which can also be invested to save radiation exposure. All in all, the tools presented here offer a large potential to minimize the deterministic and stochastic risks of radiation exposure. Springer-Verlag 2006-07-22 2006-09 /pmc/articles/PMC2663645/ /pubmed/16862409 http://dx.doi.org/10.1007/s00247-006-0212-4 Text en © Springer-Verlag 2006
spellingShingle Alara
Bernhardt, Philipp
Lendl, Markus
Deinzer, Frank
New technologies to reduce pediatric radiation doses
title New technologies to reduce pediatric radiation doses
title_full New technologies to reduce pediatric radiation doses
title_fullStr New technologies to reduce pediatric radiation doses
title_full_unstemmed New technologies to reduce pediatric radiation doses
title_short New technologies to reduce pediatric radiation doses
title_sort new technologies to reduce pediatric radiation doses
topic Alara
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2663645/
https://www.ncbi.nlm.nih.gov/pubmed/16862409
http://dx.doi.org/10.1007/s00247-006-0212-4
work_keys_str_mv AT bernhardtphilipp newtechnologiestoreducepediatricradiationdoses
AT lendlmarkus newtechnologiestoreducepediatricradiationdoses
AT deinzerfrank newtechnologiestoreducepediatricradiationdoses