Cargando…

Pediatric interventional radiography equipment: safety considerations

This paper discusses pediatric image quality and radiation dose considerations in state-of-the-art fluoroscopic imaging equipment. Although most fluoroscopes are capable of automatically providing good image quality on infants, toddlers, and small children, excessive radiation dose levels can result...

Descripción completa

Detalles Bibliográficos
Autor principal: Strauss, Keith J.
Formato: Texto
Lenguaje:English
Publicado: Springer-Verlag 2006
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2663646/
https://www.ncbi.nlm.nih.gov/pubmed/16862405
http://dx.doi.org/10.1007/s00247-006-0220-4
_version_ 1782165913080954880
author Strauss, Keith J.
author_facet Strauss, Keith J.
author_sort Strauss, Keith J.
collection PubMed
description This paper discusses pediatric image quality and radiation dose considerations in state-of-the-art fluoroscopic imaging equipment. Although most fluoroscopes are capable of automatically providing good image quality on infants, toddlers, and small children, excessive radiation dose levels can result from design deficiencies of the imaging device or inappropriate configuration of the equipment’s capabilities when imaging small body parts. Important design features and setup choices at installation and during the clinical use of the imaging device can improve image quality and reduce radiation exposure levels in pediatric patients. Pediatric radiologists and cardiologists, with the help of medical physicists, need to understand the issues involved in creating good image quality at reasonable pediatric patient doses. The control of radiographic technique factors by the generator of the imaging device must provide a large dynamic range of mAs values per exposure pulse during both fluoroscopy and image recording as a function of patient girth, which is the thickness of the patient in the posterior–anterior projection at the umbilicus (less than 10 cm to greater than 30 cm). The range of pulse widths must be limited to less than 10 ms in children to properly freeze patient motion. Variable rate pulsed fluoroscopy can be leveraged to reduce radiation dose to the patient and improve image quality. Three focal spots with nominal sizes of 0.3 mm to 1 mm are necessary on the pediatric unit. A second, lateral imaging plane might be necessary because of the child’s limited tolerance of contrast medium. Spectral and spatial beam shaping can improve image quality while reducing the radiation dose. Finally, the level of entrance exposure to the image receptor of the fluoroscope as a function of operator choices, of added filter thickness, of selected pulse rate, of the selected field-of-view and of the patient girth all must be addressed at installation.
format Text
id pubmed-2663646
institution National Center for Biotechnology Information
language English
publishDate 2006
publisher Springer-Verlag
record_format MEDLINE/PubMed
spelling pubmed-26636462009-04-23 Pediatric interventional radiography equipment: safety considerations Strauss, Keith J. Pediatr Radiol Alara This paper discusses pediatric image quality and radiation dose considerations in state-of-the-art fluoroscopic imaging equipment. Although most fluoroscopes are capable of automatically providing good image quality on infants, toddlers, and small children, excessive radiation dose levels can result from design deficiencies of the imaging device or inappropriate configuration of the equipment’s capabilities when imaging small body parts. Important design features and setup choices at installation and during the clinical use of the imaging device can improve image quality and reduce radiation exposure levels in pediatric patients. Pediatric radiologists and cardiologists, with the help of medical physicists, need to understand the issues involved in creating good image quality at reasonable pediatric patient doses. The control of radiographic technique factors by the generator of the imaging device must provide a large dynamic range of mAs values per exposure pulse during both fluoroscopy and image recording as a function of patient girth, which is the thickness of the patient in the posterior–anterior projection at the umbilicus (less than 10 cm to greater than 30 cm). The range of pulse widths must be limited to less than 10 ms in children to properly freeze patient motion. Variable rate pulsed fluoroscopy can be leveraged to reduce radiation dose to the patient and improve image quality. Three focal spots with nominal sizes of 0.3 mm to 1 mm are necessary on the pediatric unit. A second, lateral imaging plane might be necessary because of the child’s limited tolerance of contrast medium. Spectral and spatial beam shaping can improve image quality while reducing the radiation dose. Finally, the level of entrance exposure to the image receptor of the fluoroscope as a function of operator choices, of added filter thickness, of selected pulse rate, of the selected field-of-view and of the patient girth all must be addressed at installation. Springer-Verlag 2006-07-22 2006-09 /pmc/articles/PMC2663646/ /pubmed/16862405 http://dx.doi.org/10.1007/s00247-006-0220-4 Text en © Springer-Verlag 2006
spellingShingle Alara
Strauss, Keith J.
Pediatric interventional radiography equipment: safety considerations
title Pediatric interventional radiography equipment: safety considerations
title_full Pediatric interventional radiography equipment: safety considerations
title_fullStr Pediatric interventional radiography equipment: safety considerations
title_full_unstemmed Pediatric interventional radiography equipment: safety considerations
title_short Pediatric interventional radiography equipment: safety considerations
title_sort pediatric interventional radiography equipment: safety considerations
topic Alara
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2663646/
https://www.ncbi.nlm.nih.gov/pubmed/16862405
http://dx.doi.org/10.1007/s00247-006-0220-4
work_keys_str_mv AT strausskeithj pediatricinterventionalradiographyequipmentsafetyconsiderations